The DOI matches its Crossref record; 129 of the 131 references it cites were found in a registry or an index.
Time-gated Raman spectroscopy – a review
Open accessAbstract
Time-gated (TG) Raman spectroscopy (RS) has been shown to be an effective technical solution for the major problem whereby sample-induced fluorescence masks the Raman signal during spectral detection. Technical methods of fluorescence rejection have come a long way since the early implementations of large and expensive laboratory equipment, such as the optical Kerr gate. Today, more affordable small sized options are available. These improvements are largely due to advances in the production of spectroscopic and electronic components, leading to the reduction of device complexity and costs. An integral part of TG Raman spectroscopy is the temporally precise synchronization (picosecond range) between the pulsed laser excitation source and the sensitive and fast detector. The detector is able to collect the Raman signal during the short laser pulses, while fluorescence emission, which has a longer delay, is rejected during the detector dead-time. TG Raman is also resistant against ambient light as well as thermal emissions, due to its short measurement duty cycle. In recent years, the focus in the study of ultra-sensitive and fast detectors has been on gated and intensified charge coupled devices (ICCDs), or on CMOS single-photon avalanche diode (SPAD) arrays, which are also suitable for performing TG RS. SPAD arrays have the advantage of being even more sensitive, with better temporal resolution compared to gated CCDs, and without the requirement for excessive detector cooling. This review aims to provide an overview of TG Raman from early to recent developments, its applications and extensions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“These approaches are at an early technology development stage, appear to offer no compelling advantage over spontaneous Raman at higher wavelengths or software-based algorithms for fluorescence suppression, and appear to be currently limited to off-line or laboratory use [22, 26].”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [26]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Light Scattering by Small Particles
van de Hulst, H. C. (1981) · CERN Document Server (European Organization for Nuclear Research) · Cited by 7,938
Surface‐Enhanced Raman Spectroscopy: Concepts and Chemical Applications
Schlücker, S. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201205748 · Cited by 2,417
Dresselhaus, M. S. (1995) · Cited by 2,050
Topics in Fluorescence Spectroscopy
(2003) · Topics in Fluorescence Spectroscopy · doi:10.1007/0-306-47947-8 · Cited by 1,578
SERS—a single-molecule and nanoscale tool for bioanalytics
Kneipp, J., Kneipp, H., & Kneipp, K. (2008) · Chemical Society Reviews · doi:10.1039/b708459p · Cited by 1,075
Handbook of Raman Spectroscopy
Lewis, I. R., & Edwards, H. (2001) · CRC Press eBooks · doi:10.1201/9781420029253 · Cited by 528
Single-photon avalanche diode imagers in biophotonics: review and outlook
Bruschini, C., Homulle, H., Antolovic, I. M., Burri, S., & Charbon, E. (2019) · Light: Science & Applications · doi:10.1038/s41377-019-0191-5 · Cited by 512
Handbook of raman spectroscopy from the research laboratory to the process line
Lewis, I. R., & Edwards, H. G. M. (2001) · Cited by 468
Modern Raman Spectroscopy: A Practical Approach
Smith, E., & Dent, G. (2019) · Wiley eBooks · doi:10.1002/9781119440598 · Cited by 383
Characterisation and identification of bacteria using SERS
Jarvis, R. M., & Goodacre, R. (2008) · Chemical Society Reviews · doi:10.1039/b705973f · Cited by 371
Research works printed but not linked: 13
- Breed G, 2010, High Freq. Electron., 9, 1
- Smith E, 2005, Modern Raman Spectroscopy
- Nissinen I, 2011, Eur. Solid-State Device Res. Conf., 375
- Kekkonen J, 2020, IEEE Sens. J., PP, 10
- Timegate Instruments Oy F, 2020, PicoRaman
- Yoshizawa M, 2000, Phys. Rev. A - At. Mol. Opt. Phys., 61, 6
- Perelman L T, 1999, US Patent Specification, 5, 837
- 10.1051/rphysap:01984001905041500 · DOI
- Talmi Y, 1988, Proc. SPIE
- Nissinen I, 2013, European Solid-State Circuits Conf., 291
- Tanskanen P, 2017, Process Mineralogy ’17
- Garcia C S, 2009, Proc. SPIE
- Kögler M, 2018, J. Organ. Behav., 28, 303
Cited by
Hess, C. (2021) · Chemical Society Reviews · doi:10.1039/d0cs01059f · Cited by 344
The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing
Esmonde-White, K. A., Cuellar, M., & Lewis, I. R. (2022) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03727-4 · Cited by 152
“These approaches are at an early technology development stage, appear to offer no compelling advantage over spontaneous Raman at higher wavelengths or softwarebased algorithms for fluorescence suppression, and appear to be currently limited to off-line or laboratory use [22, 26].”
BackgroundGoel, R., Chakraborty, S., Awasthi, V., Bhardwaj, V., & Dubey, S. K. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115555 · Cited by 94
Stewart, H. L., & Birch, D. J. S. (2021) · Methods and Applications in Fluorescence · doi:10.1088/2050-6120/ac1dbb · Cited by 92
Cusini, I., Berretta, D., Conca, E., Incoronato, A., Madonini, F., Maurina, A. A., Nonne, C., Riccardo, S., & Villa, F. (2022) · Frontiers in Physics · doi:10.3389/fphy.2022.906671 · Cited by 69
Metadata
- Authors
- Kögler, M., & Heilala, B.
- Affiliations
- VTT Technical Research Centre of Finland (FI)
- Corresponding author
- Kögler, Martin
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2020-01-01
- Volume
- 32
- Issue
- 1
- Pages
- 012002
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W3052424341
- Cited by
- 107
- References
- 131
- Citations by year
- 2026: 13 · 2025: 23 · 2024: 26 · 2023: 23 · 2022: 11 · 2021: 9 · 2020: 2
- FWCI
- 1.41
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- iopscience.iop.org/info/page/text-and-data-mining (tdm, 300 d)
- creativecommons.org/licenses/by/4.0 (vor, 300 d)
- Locations
- Measurement Science and Technology (publishedVersion, cc-by)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
- Keywords
- time-gated Raman spectroscopy, optical Kerr gate, detector dead time, intensified CCD camera, single-photon avalanche diode array, CMOS SPAD, ambient light rejection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Time-gated Raman spectroscopy – a review. https://app.cochat.ai/papers/10.1088/1361-6501/abb044
- The paper
- Kögler, M., & Heilala, B. (2020). Time-gated Raman spectroscopy – a review. Measurement Science and Technology. https://doi.org/10.1088/1361-6501/abb044
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.