Time-gated Raman spectroscopy – a review
Open accessThe DOI matches its Crossref record; 129 of the 131 references it cites were found in a registry or an index.
Abstract
Time-gated (TG) Raman spectroscopy (RS) has been shown to be an effective technical solution for the major problem whereby sample-induced fluorescence masks the Raman signal during spectral detection. Technical methods of fluorescence rejection have come a long way since the early implementations of large and expensive laboratory equipment, such as the optical Kerr gate. Today, more affordable small sized options are available. These improvements are largely due to advances in the production of spectroscopic and electronic components, leading to the reduction of device complexity and costs. An integral part of TG Raman spectroscopy is the temporally precise synchronization (picosecond range) between the pulsed laser excitation source and the sensitive and fast detector. The detector is able to collect the Raman signal during the short laser pulses, while fluorescence emission, which has a longer delay, is rejected during the detector dead-time. TG Raman is also resistant against ambient light as well as thermal emissions, due to its short measurement duty cycle. In recent years, the focus in the study of ultra-sensitive and fast detectors has been on gated and intensified charge coupled devices (ICCDs), or on CMOS single-photon avalanche diode (SPAD) arrays, which are also suitable for performing TG RS. SPAD arrays have the advantage of being even more sensitive, with better temporal resolution compared to gated CCDs, and without the requirement for excessive detector cooling. This review aims to provide an overview of TG Raman from early to recent developments, its applications and extensions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“These approaches are at an early technology development stage, appear to offer no compelling advantage over spontaneous Raman at higher wavelengths or software-based algorithms for fluorescence suppression, and appear to be currently limited to off-line or laboratory use [22, 26].”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [26]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Light Scattering by Small Particles
van de Hulst, H. C. (1981) · CERN Document Server (European Organization for Nuclear Research) · Cited by 7,938
Surface‐Enhanced Raman Spectroscopy: Concepts and Chemical Applications
Schlücker, S. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201205748 · Cited by 2,417
Dresselhaus, M. S. (1995) · Cited by 2,050
Topics in Fluorescence Spectroscopy
(2003) · Topics in Fluorescence Spectroscopy · doi:10.1007/0-306-47947-8 · Cited by 1,578
SERS—a single-molecule and nanoscale tool for bioanalytics
Kneipp, J., Kneipp, H., & Kneipp, K. (2008) · Chemical Society Reviews · doi:10.1039/b708459p · Cited by 1,075
Handbook of Raman Spectroscopy
Lewis, I. R., & Edwards, H. (2001) · CRC Press eBooks · doi:10.1201/9781420029253 · Cited by 528
Single-photon avalanche diode imagers in biophotonics: review and outlook
Bruschini, C., Homulle, H., Antolovic, I. M., Burri, S., & Charbon, E. (2019) · Light: Science & Applications · doi:10.1038/s41377-019-0191-5 · Cited by 512
Handbook of raman spectroscopy from the research laboratory to the process line
Lewis, I. R., & Edwards, H. G. M. (2001) · Cited by 468
Modern Raman Spectroscopy: A Practical Approach
Smith, E., & Dent, G. (2019) · Wiley eBooks · doi:10.1002/9781119440598 · Cited by 383
Characterisation and identification of bacteria using SERS
Jarvis, R. M., & Goodacre, R. (2008) · Chemical Society Reviews · doi:10.1039/b705973f · Cited by 371
Raman Spectroscopy—A Prospective Tool in the Life Sciences
Petry, R., Schmitt, M., & Popp, J. (2003) · ChemPhysChem · doi:10.1002/cphc.200390004 · Cited by 368
Review of Fluorescence Suppression Techniques in Raman Spectroscopy
Wei, D., Chen, S., & Liu, Q. (2015) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2014.999936 · Cited by 334
Esmonde-White, K. A., Cuellar, M., Uerpmann, C., Lenain, B., & Lewis, I. R. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9824-1 · Cited by 332
Principles and features of single-photon avalanche diode arrays
Zappa, F., Tisa, S., Tosi, A., & Cova, S. (2007) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2007.06.021 · Cited by 329
Harz, M., Rösch, P., & Popp, J. (2009) · Cytometry Part A · doi:10.1002/cyto.a.20682 · Cited by 278
Efficient Rejection of Fluorescence from Raman Spectra Using Picosecond Kerr Gating
Matousek, P., Towrie, M., Stanley, A., & Parker, A. W. (1999) · Applied Spectroscopy · doi:10.1366/0003702991945993 · Cited by 235
Rochas, A., Gani, M., Furrer, B., Besse, P. A., Popovic, R. S., Ribordy, G., & Gisin, N. (2003) · Review of Scientific Instruments · doi:10.1063/1.1584083 · Cited by 224
Multiplier Photo-Tube Characteristics: Application to Low Light Levels*
Engstrom, R. W. (1947) · Journal of the Optical Society of America · doi:10.1364/josa.37.000420 · Cited by 210
Matousek, P., Towrie, M., Ma, C., Kwok, W. M., Phillips, D., Toner, W. T., & Parker, A. W. (2001) · Journal of Raman Spectroscopy · doi:10.1002/jrs.784 · Cited by 172
UV gated Raman spectroscopy for standoff detection of explosives
Gaft, M., & Nagli, L. (2008) · Optical Materials · doi:10.1016/j.optmat.2007.11.013 · Cited by 165
Mesu, J. G., Visser, T., Soulimani, F., & Weckhuysen, B. M. (2005) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2005.01.003 · Cited by 161
Applications of Raman Spectroscopy in Biopharmaceutical Manufacturing: A Short Review
Buckley, K., & Ryder, A. G. (2017) · Applied Spectroscopy · doi:10.1177/0003702817703270 · Cited by 160
Femtosecond time-resolved Raman spectroscopy using stimulated Raman scattering
Yoshizawa, M., & Kurosawa, M. (1999) · Physical Review A · doi:10.1103/physreva.61.013808 · Cited by 156
Fluorescence suppression in Raman spectroscopy using a time-gated CMOS SPAD
Kostamovaara, J., Tenhunen, J., Kögler, M., Nissinen, I., Nissinen, J., & Keränen, P. (2013) · Optics Express · doi:10.1364/oe.21.031632 · Cited by 156
Self-citationTime-Resolved Temperature Measurement of AlGaN/GaN Electronic Devices Using Micro-Raman Spectroscopy
Kuball, M., Riedel, G. J., Pomeroy, J. W., Sarua, A., Uren, M. J., Martin, T., Hilton, K. P., Maclean, J. O., & Wallis, D. J. (2007) · IEEE Electron Device Letters · doi:10.1109/led.2006.889215 · Cited by 153
Duyne, R. P. V., Jeanmaire, D. L., & Shriver, D. F. (1974) · Analytical Chemistry · doi:10.1021/ac60338a012 · Cited by 141
Surface Enhanced Coherent Anti-Stokes Raman Scattering on Nanostructured Gold Surfaces
Steuwe, C., Kaminski, C. F., Baumberg, J. J., & Mahajan, S. (2011) · Nano Letters · doi:10.1021/nl202875w · Cited by 139
Review of explosive detection methodologies and the emergence of standoff deep UV resonance Raman
Gares, K. L., Hufziger, K. T., Bykov, S. V., & Asher, S. A. (2016) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4868 · Cited by 136
Pharmaceutical Applications of Raman Spectroscopy
Šašić, S. (2007) · Wiley eBooks · doi:10.1002/9780470225882 · Cited by 128
Petrich, J. W., Martin, J. L., Houde, D., Poyart, C., & Orszag, A. G. (1987) · Biochemistry · doi:10.1021/bi00398a056 · Cited by 127
Raman spectroscopic study of the structural properties of CaO–MgO–SiO2–TiO2 slags
Zheng, K., Liao, J., Wang, X., & Zhang, Z. (2013) · Journal of Non-Crystalline Solids · doi:10.1016/j.jnoncrysol.2013.06.003 · Cited by 117
Time-Domain Fluorescence Spectroscopy Using Time-Correlated Single-Photon Counting
Birch, D. J. S., & Imhof, R. E. (2006) · Kluwer Academic Publishers eBooks · doi:10.1007/0-306-47057-8_1 · Cited by 111
Optimization of Raman-spectrum baseline correction in biological application
Guo, S., Bocklitz, T., & Popp, J. (2016) · The Analyst · doi:10.1039/c6an00041j · Cited by 109
Paper-based SERS analysis with smartphones as Raman spectral analyzers
Zeng, F., Mou, T., Zhang, C., Huang, X., Wang, B., Ma, X., & Guo, J. (2018) · The Analyst · doi:10.1039/c8an01901k · Cited by 108
Zong, C., Chen, C.-J., Zhang, M., Wu, D.-Y., & Ren, B. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b07197 · Cited by 106
Maruyama, Y., Blacksberg, J., & Charbon, E. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2282091 · Cited by 104
Remote spectroscopic analysis of ppm-level air pollutants by Raman spectroscopy
Hirschfeld, T., Schildkraut, E. R., Tannenbaum, H. P., & Tanenbaum, D. (1973) · Applied Physics Letters · doi:10.1063/1.1654465 · Cited by 94
Structure of CaO–B2O3–SiO2–TiO2 Glasses: a Raman Spectral Study
Wang, Z., Shu, Q., & Chou, K. (2011) · ISIJ International · doi:10.2355/isijinternational.51.1021 · Cited by 93
SPAD Image Sensor With Analog Counting Pixel for Time-Resolved Fluorescence Detection
Pancheri, L., Massari, N., & Stoppa, D. (2013) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2013.2276752 · Cited by 93
Understanding ‘appropriateness’ in multinational organizations
Cooper, D., Doucet, L., & Pratt, M. G. (2007) · Journal of Organizational Behavior · doi:10.1002/job.440 · Cited by 88
Surface-enhanced Raman spectroscopy
Popp, J., & Mayerhöfer, T. G. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2864-z · Cited by 84
Reduction of Fluorescence Background in Raman Spectra by the Pulsed Raman Technique*
Yaney, P. P. (1972) · Journal of the Optical Society of America · doi:10.1364/josa.62.001297 · Cited by 83
Sharma, S. K., Misra, A. K., Clegg, S. M., Barefield, J. E., Wiens, R. C., & Acosta, T. E. (2010) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2010.0034 · Cited by 83
Is photobleaching necessary for Raman imaging of bone tissue using a green laser?
Gölcük, K., Mandair, G. S., Callender, A. F., Sahar, N. D., Kohn, D. H., & Morris, M. D. (2006) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2006.02.022 · Cited by 79
Viscosity Property and Structure Analysis of FeO–SiO2–V2O3–TiO2–Cr2O3 Slags
Huang, W., Zhao, Y., Yu, S., Zhang, L., Ye, Z.-C., Wang, N., & Chen, M. (2016) · ISIJ International · doi:10.2355/isijinternational.isijint-2015-457 · Cited by 79
Emerging Non-invasive Raman Methods in Process Control and Forensic Applications
Macleod, N. A., & Matousek, P. (2008) · Pharmaceutical Research · doi:10.1007/s11095-008-9587-2 · Cited by 78
Viscosity Property and Melt Structure of CaO–MgO–SiO2–Al2O3–FeO Slag System
Shen, X., Chen, M., Wang, N., & Wang, D. (2019) · ISIJ International · doi:10.2355/isijinternational.isijint-2018-479 · Cited by 78
Sub-nanosecond time-resolved rejection of fluorescence from Raman spectra
Harris, J. M., Chrisman, R. W., Lytle, F. E., & Tobias, R. S. (1976) · Analytical Chemistry · doi:10.1021/ac50007a033 · Cited by 76
Picosecond Raman Spectroscopy Using a Streak Camera
Tahara, T., & Hamaguchi, H. (1993) · Applied Spectroscopy · doi:10.1366/0003702934335001 · Cited by 74
A sub-ns time-gated CMOS single photon avalanche diode detector for Raman spectroscopy
Nissinen, I., Nissinen, J., Lansman, A.-K., Hallman, L. W., Kilpelä, A., Kostamovaara, J., Kögler, M., Aikio, M., & Tenhunen, J. (2011) · European Solid-State Device Research Conference · doi:10.1109/essderc.2011.6044156 · Cited by 72
Self-citationWitkowska, E., Korsak, D., Kowalska, A. A., Księżopolska-Gocalska, M., Niedziółka‐Jönsson, J., Roźniecka, E., Michałowicz, W., Albrycht, P., Podrażka, M., Hołyst, R., et al. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-0090-z · Cited by 72
Chemical analysis using 3D printed glass microfluidics
Gal-Or, E., Gershoni, Y., Scotti, G., Nilsson, S. M. E., Saarinen, J. K. S., Jokinen, V. P., Strachan, C. J., af Gennäs, G. B., Yli‐Kauhaluoma, J. T., & Kotiaho, T. (2019) · Analytical Methods · doi:10.1039/c8ay01934g · Cited by 70
Hobro, A. J., & Lendl, B. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.08.008 · Cited by 63
Tutorial review. Time-resolved resonance Raman spectroscopy
Bell, S. E. J. (1996) · The Analyst · doi:10.1039/an996210107r · Cited by 63
Rojalin, T., Kurki, L., Laaksonen, T., Viitala, T., Kostamovaara, J., Gordon, K. C., Galvis, L., Wachsmann-Hogiu, S., Strachan, C. J., & Yliperttula, M. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-9156-6 · Cited by 63
Avalanche detector with ultraclean response for time-resolved photon counting
Spinelli, A. S., Ghioni, M., Cova, S., & Davis, L. M. (1998) · IEEE Journal of Quantum Electronics · doi:10.1109/3.668769 · Cited by 60
Development of a time-gated system for Raman spectroscopy of biological samples
Knorr, F., Smith, Z. J., & Wachsmann-Hogiu, S. (2010) · Optics Express · doi:10.1364/oe.18.020049 · Cited by 59
Real-time fouling monitoring with Raman spectroscopy
Virtanen, T., Рейникайнен, С.-П., Kögler, M., Mänttäri, M., Viitala, T., & Kallioinen, M. (2016) · Journal of Membrane Science · doi:10.1016/j.memsci.2016.12.005 · Cited by 58
Self-citationSurface-Enhanced Raman Spectroscopy: Bioanalytical, Biomolecular and Medical Applications
Procházka, M. (2016) · CERN Document Server (European Organization for Nuclear Research) · doi:10.1007/978-3-319-23992-7 · Cited by 58
Kögler, M., Ryabchikov, Y. V., Uusitalo, S., Popov, A., Popov, A. A., Tselikov, G., Välimaa, A., Al‐Kattan, A., Hiltunen, J. A., Laitinen, R., et al. (2018) · Journal of Biophotonics · doi:10.1002/jbio.201700225 · Cited by 56
Self-citationLecomte, S., Wackerbarth, H., Soulimane, T., Buse, G., & Hildebrandt, P. (1998) · Journal of the American Chemical Society · doi:10.1021/ja981130z · Cited by 55
Fast single-photon avalanche diode arrays for laser Raman spectroscopy
Blacksberg, J., Maruyama, Y., Charbon, E., & Rossman, G. R. (2011) · Optics Letters · doi:10.1364/ol.36.003672 · Cited by 50
Zięba‐Palus, J., & Michalska, A. (2014) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2014.06.007 · Cited by 49
Towards a portable Raman spectrometer using a concave grating and a time-gated CMOS SPAD
Li, Z., & Deen, M. J. (2014) · Optics Express · doi:10.1364/oe.22.018736 · Cited by 48
Blacksberg, J., Alerstam, E., Maruyama, Y., Cochrane, C. J., & Rossman, G. R. (2016) · Applied Optics · doi:10.1364/ao.55.000739 · Cited by 48
Time-resolved Raman spectroscopy for in situ planetary mineralogy
Blacksberg, J., Rossman, G. R., & Gleckler, A. D. (2010) · Applied Optics · doi:10.1364/ao.49.004951 · Cited by 47
Nissinen, I., Nissinen, J., Keränen, P., Stoppa, D., & Kostamovaara, J. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2813531 · Cited by 47
Surface-enhanced femtosecond CARS spectroscopy (SE-CARS) on pyridine
Namboodiri, V. V., Namboodiri, M., Diaz, G. I. C., Oppermann, M., Flachenecker, G., & Materny, A. (2010) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2010.08.005 · Cited by 43
Photoelectric Detection and Intensity Measurement in Raman Spectra
Rank, D. H., Pfister, R. J., & Coleman, P. D. (1942) · Journal of the Optical Society of America · doi:10.1364/josa.32.000390 · Cited by 43
Nature of surface-enhanced coherent Raman scattering
Hua, X., Voronine, D. V., Ballmann, C. W., Sinyukov, A. M., Sokolov, A. V., & Scully, M. O. (2014) · Physical Review A · doi:10.1103/physreva.89.043841 · Cited by 43
Characteristics of Hot Water Extracts from the Bark of Cultivated Willow (Salix sp.)
Dou, J., Xu, W., Koivisto, J. J., Mobley, J. K., Padmakshan, D., Kögler, M., Xu, C., Willför, S. M., Ralph, J., & Vuorinen, T. (2018) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.8b00498 · Cited by 43
Self-citationTime-Gated Single-Photon Detection in Time-Domain Diffuse Optics: A Review
Mora, A. D. D., Sieno, L. D., Re, R., Pifferi, A., & Contini, D. (2020) · Applied Sciences · doi:10.3390/app10031101 · Cited by 43
Moon, J., Mahon, R., Duncan, M. D., & Reintjes, J. F. (1994) · Optics Letters · doi:10.1364/ol.19.001234 · Cited by 41
Deep Subsurface Raman Spectroscopy of Turbid Media by a Defocused Collection System
Eliasson, C., Claybourn, M., & Matousek, P. (2007) · Applied Spectroscopy · doi:10.1366/000370207782217770 · Cited by 41
Sowoidnich, K., & Kronfeldt, H.-D. (2012) · ISRN Spectroscopy · doi:10.5402/2012/256326 · Cited by 39
High-Sensitive Smartphone-Based Raman System Based on Cloud Network Architecture
Mu, T., Li, S., Feng, H., Zhang, C., Wang, B., Ma, X., Guo, J., Huang, B. X., & Zhu, L. (2018) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2018.2832661 · Cited by 38
Photomultiplier Gate for Stimulated-Spontaneous Light Scattering Discrimination
Martini, F. D., & Wacks, K. P. (1967) · Review of Scientific Instruments · doi:10.1063/1.1720912 · Cited by 37
A portable shifted excitation Raman difference spectroscopy system: device and field demonstration
Maiwald, M., Müller, A., Sumpf, B., & Tränkle, G. (2016) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4953 · Cited by 37
Time‐gated Raman and laser‐induced breakdown spectroscopy in mapping of eudialyte and catapleiite
Romppanen, S., Häkkänen, H., Kekkonen, J., Nissinen, J., Nissinen, I., Kostamovaara, J., & Kaski, S. (2019) · Journal of Raman Spectroscopy · doi:10.1002/jrs.5622 · Cited by 37
Fluorescence suppression in time-resolved Raman spectra
Burgess, S., & Shepherd, I. W. (1977) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/10/6/015 · Cited by 35
Multichannel Raman spectroscopy
Campion, A., & Woodruff, W. H. (1987) · Analytical Chemistry · doi:10.1021/ac00149a001 · Cited by 33
Fluorescence rejection in Raman spectroscopy using a gated intensified diode array detector
Everall, N. J., Jackson, R. W., Howard, J. A. K., & Hutchinson, K. (1986) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1250170507 · Cited by 33
Time-resolved stand-off UV-Raman spectroscopy for planetary exploration
Skulinová, M., Lefebvre, C., Sobrón, P., Eshelman, E. J., Daly, M. G., Gravel, J.-F., Cormier, J.-F., Chateauneuf, F. J., Slater, G. F., Zheng, W., et al. (2014) · Planetary and Space Science · doi:10.1016/j.pss.2014.01.010 · Cited by 32
Position sensitive detector for fluorescence lifetime imaging
Prokazov, Y., Turbin, E., Weber, A., Hartig, R., & Zuschratter, W. (2014) · Journal of Instrumentation · doi:10.1088/1748-0221/9/12/c12015 · Cited by 31
Determining the Spectral Resolution of a Charge-Coupled Device (CCD) Raman Instrument
Liu, C., & Berg, R. W. (2012) · Applied Spectroscopy · doi:10.1366/11-06508 · Cited by 30
Comparison of time and frequency domain methods for rejecting fluorescence from Raman spectra
Wirth, M. J., & Chou, S. H. (1988) · Analytical Chemistry · doi:10.1021/ac00169a009 · Cited by 30
Nissinen, I., Nissinen, J., Keränen, P., & Kostamovaara, J. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.10.021 · Cited by 30
Photoluminescence: Science and Applications
Lefebvre, J., Maruyama, S., & Finnie, P. (2007) · Topics in applied physics · doi:10.1007/978-3-540-72865-8_9 · Cited by 29
Fluorescence rejection in Raman spectroscopy by a gated single-photon counting method
Watanabe, J., Kinoshita, S., & Kushida, T. (1985) · Review of Scientific Instruments · doi:10.1063/1.1138028 · Cited by 29
Kögler, M., Itkonen, J., Viitala, T., & Casteleijn, M. G. (2020) · Scientific Reports · doi:10.1038/s41598-020-59091-3 · Cited by 29
Self-citationHoward, J. A. K., Everall, N. J., Jackson, R. W., & Hutchinson, K. (1986) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/19/11/013 · Cited by 28
Assal, Z. E., Ojala, S., Zbair, M., Echchtouki, H., Nevanperä, T. K., Pitkäaho, S., Pirault‐Roy, L., Bensitel, M., Brahmi, R., & Keiski, R. L. (2019) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.04.073 · Cited by 25
Time resolved Raman spectroscopy for depth analysis of multi‐layered mineral samples
Hooijschuur, J., Petterson, I. E. I., Davies, G. R., Gooijer, C., & Ariese, F. (2013) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4369 · Cited by 24
Lundberg, E., & Jonansson, G. (1976) · Analytical Chemistry · doi:10.1021/ac50007a029 · Cited by 24
The third generation of multichannel Raman spectrometers
Deffontaine, A., Bridoux, M., DELHAYE, M., Silva, E. D., & Hug, W. (1984) · Revue de Physique Appliquée · doi:10.1051/rphysap:01984001905041500 · Cited by 24
Kekkonen, J., Finnilä, M., Heikkilä, J., Anttonen, V., & Nissinen, I. (2019) · The Analyst · doi:10.1039/c9an01136f · Cited by 24
Courtney, S. H., & Wilson, W. L. (1991) · Review of Scientific Instruments · doi:10.1063/1.1142373 · Cited by 23
Koivikko, N., Laitinen, T., Mouammine, A., Ojala, S., & Keiski, R. L. (2018) · Catalysts · doi:10.3390/catal8020056 · Cited by 23
Antcliff, R. R., Hillard, M. E., & Jarrett, O. (1984) · Applied Optics · doi:10.1364/ao.23.002369 · Cited by 22
Nissinen, I., Lansman, A.-K., Nissinen, J., Holma, J., & Kostamovaara, J. (2013) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2013.6649130 · Cited by 20
Luminescent materials: probing the excited state of emission centers by spectroscopic methods
Mihóková, E., & Nikl, M. (2014) · Measurement Science and Technology · doi:10.1088/0957-0233/26/1/012001 · Cited by 20
Ariunbold, G. O., & Altangerel, N. (2016) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4987 · Cited by 19
Usai, A., Finlayson, N., Gregory, C. D., Campbell, C. J., & Henderson, R. (2019) · Optical Biopsy: Toward Real-Time Spectroscopic Imaging and Diagnosis · doi:10.1117/12.2508459 · Cited by 18
Gulati, K. K., Gulia, S., Gambhir, T., Kumar, N., Gambhir, V., & Reedy, M. N. (2019) · Defence Science Journal · doi:10.14429/dsj.69.13234 · Cited by 17
Yaney, P. P. (1976) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1250050304 · Cited by 16
Kekkonen, J., Talala, T., Nissinen, J., & Nissinen, I. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2966119 · Cited by 16
Blacksberg, J., Alerstam, E., Cochrane, C. J., Maruyama, Y., & Farmer, J. D. (2020) · Applied Optics · doi:10.1364/ao.59.000433 · Cited by 16
Kudryavtsev, D. A., Fedotenko, T., Koemets, E., Khandarkhaeva, S., Kutcherov, V. G., & Dubrovinsky, L. (2020) · Scientific Reports · doi:10.1038/s41598-020-58520-7 · Cited by 15
The SuperCam Instrument for the Mars 2020 Rover
Nelson, T., Wiens, R. C., Clegg, S. M., Newell, R., Robinson, S. H., Storms, S., Michel, J. M., Caffrey, M. P., Deming, J., Sandoval, B., et al. (2020) · IEEE Aerospace Conference (AERO) · doi:10.1109/aero47225.2020.9172661 · Cited by 14
Gyakwaa, F., Aula, M., Alatarvas, T., Vuolio, T., Huttula, M., & Fabritius, T. M. J. (2019) · ISIJ International · doi:10.2355/isijinternational.isijint-2019-122 · Cited by 14
Study of minerals, organic, and biogenic materials through time-resolved Raman spectroscopy
Garcia, C. S., Abedin, M. N., Ismail, S., Sharma, S. K., Misra, A. K., Nguyen, T., & Elsayed-Ali, H. E. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.818169 · Cited by 13
Kögler, M., Paul, A., Anane, E., Birkholz, M., Bunker, A., Viitala, T., Maiwald, M., Junne, S. G., & Neubauer, P. B. (2018) · Biotechnology Progress · doi:10.1002/btpr.2665 · Cited by 12
Self-citationGueutue, E. S. F., Canizarès, A., Simon, P., Raimboux, N., Hennet, L., & Ammar, M. R. (2018) · Journal of Raman Spectroscopy · doi:10.1002/jrs.5345 · Cited by 11
Latest improvements of microchannel-plate PMTS
Lehmann, A., Böhm, M., Miehling, D., Pfaffinger, M., Stelter, S., Uhlig, F., Ali, A., Belias, A., Dzhygadlo, R., Gerhardt, A., et al. (2019) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2019.162357 · Cited by 10
Sweep circuit design for a picosecond streak camera
Baker, R. J., & Johnson, B. P. (1994) · Measurement Science and Technology · doi:10.1088/0957-0233/5/4/014 · Cited by 9
Heilala, B., Mäkinen, A., Nissinen, I., Nissinen, J., Mäkynen, A., & Perämäki, P. (2017) · Microchemical Journal · doi:10.1016/j.microc.2017.11.010 · Cited by 9
Self-citationAdvanced Raman spectroscopy for bioprocess monitoring
Kögler, M. (2018) · DepositOnce · doi:10.14279/depositonce-6684 · Cited by 9
Self-citationKekkonen, J., Nissinen, J., Kostamovaara, J., & Nissinen, I. (2018) · Sensors · doi:10.3390/s18103200 · Cited by 9
Smith, J. A., Dhulla, V. H., Mukherjee, S., Lauenstein, J., Hare, R. J., Zorn, C., & Hostetler, C. A. (2020) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2020.2979808 · Cited by 9
Picosecond time-gated Raman spectroscopy for transcutaneous evaluation of bone composition
Morris, M. D., Draper, E. R. C., Goodship, A. E., Matousek, P., Towrie, M., Parker, A. W., & Pleshko, N. L. (2005) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.585457 · Cited by 8
Böttger, U., Maiwald, M., Hanke, F., Braune, M., Pavlov, S. G., Schröder, S., Weber, I., Busemann, H., Sumpf, B., Tränkle, G., et al. (2017) · Planetary and Space Science · doi:10.1016/j.pss.2017.05.004 · Cited by 8
Standoff Raman measurement of nitrates in water
Sadate, S., Kassu, A., Farley, C., Sharma, A., Hardisty, J., & Lifson, M. (2011) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.893571 · Cited by 7
Pulsed Multichannel Raman Technique
Deffontaine, A., DELHAYE, M., & Bridoux, M. (1985) · Springer proceedings in physics · doi:10.1007/978-3-642-47541-2_5 · Cited by 7
Xia, J., Yao, Q.-F., Zhu, L., Dong, M., & Lou, X. (2019) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2019.01.001 · Cited by 7
Panasenko, D., Sun, P.-C., Alić, N., & Fainman, Y. (2002) · Applied Optics · doi:10.1364/ao.41.005185 · Cited by 6
Yanagisawa, S., Deshpande, M. S., Hirota, S., Nakagawa, T., & Ogura, T. (2017) · Journal of Raman Spectroscopy · doi:10.1002/jrs.5100 · Cited by 5
Guidelines For The Selection Of Raman Multichannel Detectors
Talmi, Y. (1988) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.941947 · Cited by 1
Duppenbecker, P. M., Haagen, R., Lodomez, S., Marsden, P. K., & Schulz, V. (2011) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2011.6153866 · Cited by 1
Uusitalo, S., Kögler, M., Popov, A., Ryabchikov, Y. V., Bibikova, O., Alakomi, H., Juvonen, R., Kontturi, V., Siitonen, S., Välimaa, A., et al. (2019) · Nanoscale and Quantum Materials: From Synthesis and Laser Processing to Applications · doi:10.1117/12.2513956 · Cited by 1
Self-citation
Research works printed but not linked: 8
- Breed G 2010 Fundamentals of pulsed and time-gated measurements High Freq. Electron. 9 1-4
- Smith E and Dent G 2005 Modern Raman Spectroscopy (New York: Wiley)
- Timegate Instruments Oy F 2020 PicoRaman
- Perelman L T, Wu J, Wang Y, Dasari R R, Itzkan I and Feld S M 1999 Optical imaging using time gated scattered light US Patent Specification 5,837,964 19
- Deffontaine A, Bridoux M and Delhaye M 1984 The third generation of multichannel Raman spectrometers Rev. Phys. Appl. 19 415-21 · DOI
- Li Z 2015 Miniaturization of Time-Gated Raman Spectrometer with a Concave Grating and a CMOS Single Photon Avalanche Diode Miniaturization of time-gated Raman spectrometer with a concave grating and a CMOS single photon avalanche diode Ph.D Thesis, McMaster University
- Tanskanen P, Heilala B, Kurki L, Lamberg P, Savela J and Fabritius T 2017 On-line monitoring of spodumene heat treatment process with time-gated Raman spectroscopy: Process Mineralogy '17 (Cape Town)
- Kögler M et al 2018 Bare laser-synthesized Au-based nanoparticles as non-disturbing SERS probes for Bacteria Identification J. Organ. Behav. 28 303-25
Cited by
Hess, C. (2021) · Chemical Society Reviews · doi:10.1039/d0cs01059f · Cited by 344
The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing
Esmonde-White, K. A., Cuellar, M., & Lewis, I. R. (2022) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03727-4 · Cited by 152
“These approaches are at an early technology development stage, appear to offer no compelling advantage over spontaneous Raman at higher wavelengths or softwarebased algorithms for fluorescence suppression, and appear to be currently limited to off-line or laboratory use [22, 26].”
BackgroundGoel, R., Chakraborty, S., Awasthi, V., Bhardwaj, V., & Dubey, S. K. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115555 · Cited by 94
Stewart, H. L., & Birch, D. J. S. (2021) · Methods and Applications in Fluorescence · doi:10.1088/2050-6120/ac1dbb · Cited by 92
Cusini, I., Berretta, D., Conca, E., Incoronato, A., Madonini, F., Maurina, A. A., Nonne, C., Riccardo, S., & Villa, F. (2022) · Frontiers in Physics · doi:10.3389/fphy.2022.906671 · Cited by 69
Metadata
- Authors
- Kögler, M., & Heilala, B.
- Affiliations
- VTT Technical Research Centre of Finland (FI)
- Corresponding author
- Kögler, Martin
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2020-01-01
- Volume
- 32
- Issue
- 1
- Pages
- 012002
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W3052424341
- Cited by
- 107
- References
- 131
- Citations by year
- 2026: 13 · 2025: 23 · 2024: 26 · 2023: 23 · 2022: 11 · 2021: 9 · 2020: 2
- FWCI
- 1.41
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- iopscience.iop.org/info/page/text-and-data-mining (tdm, 300 d)
- creativecommons.org/licenses/by/4.0 (vor, 300 d)
- Locations
- Measurement Science and Technology (publishedVersion, cc-by)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
- Keywords
- time-gated Raman spectroscopy, optical Kerr gate, detector dead time, intensified CCD camera, single-photon avalanche diode array, CMOS SPAD, ambient light rejection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.