Time-gated Raman spectroscopy – a review
Open accessThe DOI matches its Crossref record; 129 of the 131 references it cites were found in a registry or an index.
Abstract
Time-gated (TG) Raman spectroscopy (RS) has been shown to be an effective technical solution for the major problem whereby sample-induced fluorescence masks the Raman signal during spectral detection. Technical methods of fluorescence rejection have come a long way since the early implementations of large and expensive laboratory equipment, such as the optical Kerr gate. Today, more affordable small sized options are available. These improvements are largely due to advances in the production of spectroscopic and electronic components, leading to the reduction of device complexity and costs. An integral part of TG Raman spectroscopy is the temporally precise synchronization (picosecond range) between the pulsed laser excitation source and the sensitive and fast detector. The detector is able to collect the Raman signal during the short laser pulses, while fluorescence emission, which has a longer delay, is rejected during the detector dead-time. TG Raman is also resistant against ambient light as well as thermal emissions, due to its short measurement duty cycle. In recent years, the focus in the study of ultra-sensitive and fast detectors has been on gated and intensified charge coupled devices (ICCDs), or on CMOS single-photon avalanche diode (SPAD) arrays, which are also suitable for performing TG RS. SPAD arrays have the advantage of being even more sensitive, with better temporal resolution compared to gated CCDs, and without the requirement for excessive detector cooling. This review aims to provide an overview of TG Raman from early to recent developments, its applications and extensions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“These approaches are at an early technology development stage, appear to offer no compelling advantage over spontaneous Raman at higher wavelengths or software-based algorithms for fluorescence suppression, and appear to be currently limited to off-line or laboratory use [22, 26].”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [26]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Light Scattering by Small Particles
van de Hulst, H. C. (1981) · CERN Document Server (European Organization for Nuclear Research) · Cited by 7,938
Surface‐Enhanced Raman Spectroscopy: Concepts and Chemical Applications
Schlücker, S. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201205748 · Cited by 2,417
Dresselhaus, M. S. (1995) · Cited by 2,050
Topics in Fluorescence Spectroscopy
(2003) · Topics in Fluorescence Spectroscopy · doi:10.1007/0-306-47947-8 · Cited by 1,578
SERS—a single-molecule and nanoscale tool for bioanalytics
Kneipp, J., Kneipp, H., & Kneipp, K. (2008) · Chemical Society Reviews · doi:10.1039/b708459p · Cited by 1,075
Handbook of Raman Spectroscopy
Lewis, I. R., & Edwards, H. (2001) · CRC Press eBooks · doi:10.1201/9781420029253 · Cited by 528
Single-photon avalanche diode imagers in biophotonics: review and outlook
Bruschini, C., Homulle, H., Antolovic, I. M., Burri, S., & Charbon, E. (2019) · Light: Science & Applications · doi:10.1038/s41377-019-0191-5 · Cited by 512
Handbook of raman spectroscopy from the research laboratory to the process line
Lewis, I. R., & Edwards, H. G. M. (2001) · Cited by 468
Modern Raman Spectroscopy: A Practical Approach
Smith, E., & Dent, G. (2019) · Wiley eBooks · doi:10.1002/9781119440598 · Cited by 383
Characterisation and identification of bacteria using SERS
Jarvis, R. M., & Goodacre, R. (2008) · Chemical Society Reviews · doi:10.1039/b705973f · Cited by 371
Research works printed but not linked: 8
- Breed G 2010 Fundamentals of pulsed and time-gated measurements High Freq. Electron. 9 1-4
- Smith E and Dent G 2005 Modern Raman Spectroscopy (New York: Wiley)
- Timegate Instruments Oy F 2020 PicoRaman
- Perelman L T, Wu J, Wang Y, Dasari R R, Itzkan I and Feld S M 1999 Optical imaging using time gated scattered light US Patent Specification 5,837,964 19
- Deffontaine A, Bridoux M and Delhaye M 1984 The third generation of multichannel Raman spectrometers Rev. Phys. Appl. 19 415-21 · DOI
- Li Z 2015 Miniaturization of Time-Gated Raman Spectrometer with a Concave Grating and a CMOS Single Photon Avalanche Diode Miniaturization of time-gated Raman spectrometer with a concave grating and a CMOS single photon avalanche diode Ph.D Thesis, McMaster University
- Tanskanen P, Heilala B, Kurki L, Lamberg P, Savela J and Fabritius T 2017 On-line monitoring of spodumene heat treatment process with time-gated Raman spectroscopy: Process Mineralogy '17 (Cape Town)
- Kögler M et al 2018 Bare laser-synthesized Au-based nanoparticles as non-disturbing SERS probes for Bacteria Identification J. Organ. Behav. 28 303-25
Cited by
Items 101–130 of 130
Application to the cultural, natural, and industrial heritage
Colomban, P. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-15989-3.00005-5
Maubois, B. (2024) · PolyPublie (École Polytechnique de Montréal)
Biobarrierien mittausmenetelmät paperin ja kartongin jatkojalostuksessa
Ojanen, H. (2024) · Jyväskylä University Digital Archive (University of Jyväskylä)
Rebellato Giordano Martim, F. (2024) · KTH Publication Database DiVA (KTH Royal Institute of Technology)
Development of an Endonasal Raman Spectroscopy Probe for Transsphenoidal Pituitary Adenoma Surgery
Blanquez-Yeste, V. (2025) · PolyPublie (École Polytechnique de Montréal)
1763 Werkzeuge der Katalyseforschung
Grünert, W., Kleist, W., & Muhler, M. (2025) · De Gruyter eBooks · doi:10.1515/9783111344454-003
Collard, L. (2026) · Light Advanced Manufacturing · doi:10.37188/lam.2026.017
Online monitoring of bioreactors by Raman spectroscopy and machine learning
Yang, N. (2024) · theses.fr (ABES) · doi:10.70675/cfae52a0zdcd5z41a8z877bz3023f86d9a13
Shiozaki, Y., & Fujita, K. (2026) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2026.127926
Pedari, S. N., Le, H. M., Tran, V., Grégoire, D. S., & Hu, Y. (2026) · Waste Management · doi:10.1016/j.wasman.2026.115826
Future developments in portable optical spectroscopy
Crocombe, R. A., Leary, P. E., & Kammrath, B. W. (2026) · doi:10.1117/12.3087147
A 128 × 1 SPAD-Camera for Protein Sequencing through Surface-Enhanced Raman Spectroscopy
Storari, V., Terragni, C., Difato, F., Tantussi, F., Weinacker, J., Wegener, M., Angelis, F. D., & Villa, F. (2026) · Virtual Community of Pathological Anatomy (University of Castilla La Mancha)
Hiis, H., Ratso, S., Danilson, M., Mikli, V., Boukos, N. K., Banis, A., Liivand, K., & Kaare, K. (2026) · Carbon · doi:10.1016/j.carbon.2026.121781
A 32-channel, 48 ps Resolution, Expandable TDC for Gated-Raman Spectroscopy
Li, Y., Yu, H., & Ma, S. (2025) · doi:10.1109/iccs66653.2025.11569725
Liang, Q., & Song, G. (2026) · Journal of Raman Spectroscopy · doi:10.1002/jrs.70196
A Time-Gated Raman Spectroscopy and Mass Spectrometry Comparative Chemical Analysis of Plasticizers
Rieland, J. M., Simón‐Manso, Y., Zuber, A., Kotula, A. P., Migler, K. B., Wallace, W. E., & Beers, K. L. (2026) · ACS Polymers Au · doi:10.1021/acspolymersau.6c00065
Wang, N., Guo, H., Sun, Q., Zhang, X., 钮元元, Zha, L., Feng, H., Fang, G., Zhang, W., Zhong, L., et al. (2026) · Fuel · doi:10.1016/j.fuel.2026.140793
A 48 ps resolution, timing chip constructed from two expandable 32-channel register-only TDCs
Yu, H., Yang, J., Li, Y., Ge, B., Shen, J., Si, L., & Ma, S. (2026) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-026-02618-x
Lin, R., Lu, Y., Mo, D., & Shen, H. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7350314
Possibility of using time-gated Raman spectroscopy in remote sensing applications
Kutuza, I. B., Zinin, P. V., & Bulatov, K. M. (2026) · Modern Problems of Remote Sensing, Radar, Wave Propagation and Diffraction · doi:10.66032/2304-0297-2026-1-1-436-439
Time-Gated Raman Spectroscopic Characterization of Fluorescent Polyethylene Microplastics
Narvaez, K., Ebert, C., Zanazzi, M., Boitor, R., Corden, C., Rocks, S. S., Notingher, I., & Shipp, D. W. (2026) · Applied Spectroscopy · doi:10.1177/00037028261486537
Analytical and Spectroscopic Tools for Studying Enzyme Transition States
Fontanelli, M., Conciani, G., Correa, L., de Godoy, M. M., & Netto, C. G. C. M. (2026) · Analysis & Sensing · doi:10.1002/anse.70121
Utilization of process analytical technologies in the process monitoring of biopharmaceuticals
Hihnala, T. (2025) · UEF eRepo (University of Eastern Finland)
Mäkiniemi, K. (2024) · UEF eRepo (University of Eastern Finland)
Song, M., Lu, M., Jing, X., Yin, Z., Li, S., & li, J. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7560347
Investigating Transferability of Multivariate Calibration Models for Bioprocessing Applications
Umprecht, A. (2026) · reposiTUm (TU Wien) · doi:10.34726/hss.2026.144580
Dou, J., Lahtinen, M. H., Kögler, M., Klemettinen, L., Niemelä, K., Meinander, K., Haatainen, T., Tervola, P., & Vehmaa, J. (2026) · Journal of Hazardous Materials Advances · doi:10.1016/j.hazadv.2026.101670
Self-citationHuo, T., Li, Y., Kumar, S., Andreescu, S., Huang, Y., & Du, H. (2026) · Sensors · doi:10.3390/s26216865
The Ultrafast Multimodal Toolbox: Mapping Matter in Motion across Scales
Liu, J., Tang, M., & Luo, F. C. (2026) · Photon Science · doi:10.1021/photonsci.6c00001
Metadata
- Authors
- Kögler, M., & Heilala, B.
- Affiliations
- VTT Technical Research Centre of Finland (FI)
- Corresponding author
- Kögler, Martin
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2020-01-01
- Volume
- 32
- Issue
- 1
- Pages
- 012002
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W3052424341
- Cited by
- 107
- References
- 131
- Citations by year
- 2026: 13 · 2025: 23 · 2024: 26 · 2023: 23 · 2022: 11 · 2021: 9 · 2020: 2
- FWCI
- 1.41
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- iopscience.iop.org/info/page/text-and-data-mining (tdm, 300 d)
- creativecommons.org/licenses/by/4.0 (vor, 300 d)
- Locations
- Measurement Science and Technology (publishedVersion, cc-by)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
- Keywords
- time-gated Raman spectroscopy, optical Kerr gate, detector dead time, intensified CCD camera, single-photon avalanche diode array, CMOS SPAD, ambient light rejection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.