Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 218

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Computed tomography super-resolution using deep convolutional neural network

Open access
Park, Junyoung, Hwang, Donghwi, Kim, Kyeong Yun, Kang, Seung Kwan, Kim, Yu Kyeong, Lee, Jae Sung · 2018 · Physics in Medicine & Biology

Abstract

The objective of this study is to develop a convolutional neural network (CNN) for computed tomography (CT) image super-resolution. The network learns an end-to-end mapping between low (thick-slice thickness) and high (thin-slice thickness) resolution images using the modified U-Net. To verify the proposed method, we train and test the CNN using axially averaged data of existing thin-slice CT images as input and their middle slice as the label. Fifty-two CT studies are used as the CNN training set, and 13 CT studies are used as the test set. We perform five-fold cross-validation to confirm the performance consistency. Because all input and output images are used in two-dimensional slice format, the total number of slices for training the CNN is 7670. We assess the performance of the proposed method with respect to the resolution and contrast, as well as the noise properties. The CNN generates output images that are virtually equivalent to the ground truth. The most remarkable image-recovery improvement by the CNN is deblurring of boundaries of bone structures and air cavities. The CNN output yields an approximately 10% higher peak signal-to-noise ratio and lower normalized root mean square error than the input (thicker slices). The CNN output noise level is lower than the ground truth and equivalent to the iterative image reconstruction result. The proposed deep learning method is useful for both super-resolution and de-noising.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1361-6560/aacdd4

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 218

Metadata

Authors
Park, J., Hwang, D., Kim, K. Y., Kang, S. K., Kim, Y. K., & Lee, J. S.
Venue
Physics in Medicine & Biology
Published
2018-07-16
Volume
63
Issue
14
Pages
145011
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W2809226111
Cited by
218
References
6
FWCI
10.59
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Computed tomography super-resolution using deep convolutional neural network. https://app.cochat.ai/papers/10.1088/1361-6560/aacdd4
The paper
Park, J., Hwang, D., Kim, K. Y., Kang, S. K., Kim, Y. K., & Lee, J. S. (2018). Computed tomography super-resolution using deep convolutional neural network. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/aacdd4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.