CASToR: a generic data organization and processing code framework for multi-modal and multi-dimensional tomographic reconstruction
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
In tomographic medical imaging (PET, SPECT, CT), differences in data acquisition and organization are a major hurdle for the development of tomographic reconstruction software. The implementation of a given reconstruction algorithm is usually limited to a specific set of conditions, depending on the modality, the purpose of the study, the input data, or on the characteristics of the reconstruction algorithm itself. It causes restricted or limited use of algorithms, differences in implementation, code duplication, impractical code development, and difficulties for comparing different methods. This work attempts to address these issues by proposing a unified and generic code framework for formatting, processing and reconstructing acquired multi-modal and multi-dimensional data. The proposed iterative framework processes in the same way elements from list-mode (i.e. events) and histogrammed (i.e. sinogram or other bins) data sets. Each element is processed separately, which opens the way for highly parallel execution. A unique iterative algorithm engine makes use of generic core components corresponding to the main parts of the reconstruction process. Features that are specific to different modalities and algorithms are embedded into specific components inheriting from the generic abstract components. Temporal dimensions are taken into account in the core architecture. The framework is implemented in an open-source C++ parallel platform, called CASToR (customizable and advanced software for tomographic reconstruction). Performance assessments show that the time loss due to genericity remains acceptable, being one order of magnitude slower compared to a manufacturer's software optimized for computational efficiency for a given system geometry. Specific optimizations were made possible by the underlying data set organization and processing and allowed for an average speed-up factor ranging from 1.54 to 3.07 when compared to more conventional implementations. Using parallel programming, an almost linear speed-up increase (factor of 0.85 times number of cores) was obtained in a realistic clinical PET setting. In conclusion, the proposed framework offers a substantial flexibility for the integration of new reconstruction algorithms while maintaining computation efficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319 · cited 1×
“For comparison, the simulated data were also reconstructed with the RTK software (Rit et al 2014), using the Feldkamp-David-Kress algorithm (Feldkamp et al 1984) and a Hann filter (at Nyquist cut-off frequency).”
MethodMaximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Fast calculation of the exact radiological path for a three‐dimensional CT array
Siddon, R. L. (1985) · Medical Physics · doi:10.1118/1.595715 · Cited by 1,535 · cited 5×
“For a fair comparison, the native sampling was also used for the CASToR reconstruction, using the Siddon projector (Siddon 1985).”
MethodInfluentialAn Iteration Formula for Fredholm Integral Equations of the First Kind
Landweber, L. (1951) · American Journal of Mathematics · doi:10.2307/2372313 · Cited by 1,103 · cited 2×
“…optimizers include MLEM (Shepp & Vardi 1982) for both emission (list-mode and histogrammed data) and transmission (histogram) data, the Landweber’s (Landweber 1951) for both emission and transmission histogrammed data, MLTR (Nuyts et al 1998, Slambrouck & Nuyts 2014) for transmission histogrammed…”
MethodThe ASTRA Toolbox: A platform for advanced algorithm development in electron tomography
van Aarle, W., Palenstijn, W. J., De Beenhouwer, J., Altantzis, T., Bals, S., Batenburg, K. J., & Sijbers, J. (2015) · Ultramicroscopy · doi:10.1016/j.ultramic.2015.05.002 · Cited by 973 · cited 2×
“Several software packages have been proposed for CT, including RTK (Rit et al 2014) (an ITK-based package focused on cone-beam CT reconstruction), the Astra-Toolbox (van Aarle et al 2015) (a MATLAB and Python toolbox of high-performance GPU primitives for 2D and 3D tomography implementing a large number of algorithms…”
MethodJan, S., Benoit, D., Becheva, E., Carlier, T., Cassol, F., Descourt, P., Frisson, T., Grevillot, L., Guigues, L., Maigne, L., et al. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/4/001 · Cited by 794
Self-citationIterative reconstruction methods in X-ray CT
Beister, M., Kolditz, D., & Kalender, W. A. (2012) · Physica Medica · doi:10.1016/j.ejmp.2012.01.003 · Cited by 751 · cited 1×
“The wide use of iterative methods in PET an SPECT and the re-emergence of iterative reconstruction in CT (Beister et al 2012) suggest that reconstruction software for these three modalities can be efficiently integrated into a unified iterative reconstruction framework.”
MethodSTIR: software for tomographic image reconstruction release 2
Thielemans, K., Tsoumpas, C., Mustafovic, S., Beisel, T., Aguiar, P., Dikaios, N., & Jacobson, M. W. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/4/867 · Cited by 466 · cited 1×
“For emission tomography, STIR (Thielemans et al 2012) is an Open Source software providing a Multi-Platform Object-Oriented framework for image reconstruction in PET and SPECT as well as for the estimation of data correction terms.”
MethodDistance-driven projection and backprojection in three dimensions
Man, B. D., & Basu, S. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/11/024 · Cited by 459 · cited 4×
“The results do not reflect the fact that the average number of voxels contributing to a ray is the smallest for Siddon’s, followed by Joseph’s and Distance-Driven projector.”
MethodInfluentialA row-action alternative to the EM algorithm for maximizing likelihood in emission tomography
Browne, J., & de Pierro, A. B. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538946 · Cited by 424 · cited 1×
“The implementation of the RAMLA algorithm (Browne & de Pierro 1996) would need a specific events ordering within the datafile, matching the way the loop over events is performed, in order to be valid.”
Method
Cited by
Advanced Monte Carlo simulations of emission tomography imaging systems with GATE
Sarrut, D., Bała, M., Bardiès, M., Bert, J., Chauvin, M., Chatzipapas, K., Dupont, M., Etxebeste, A., M Fanchon, L., Jan, S., et al. (2021) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abf276 · Cited by 204
Self-citation
Metadata
- Authors
- Merlin, T., Stute, S., Benoit, D., Bert, J., Carlier, T., Comtat, C., Filipovic, M., Lamare, F., & Visvikis, D.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2018-09-10
- Volume
- 63
- Issue
- 18
- Pages
- 185005
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2885633224
- Cited by
- 236
- References
- 25
- FWCI
- 17.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CASToR: a generic data organization and processing code framework for multi-modal and multi-dimensional tomographic reconstruction. https://app.cochat.ai/papers/10.1088/1361-6560/aadac1
- The paper
- Merlin, T., Stute, S., Benoit, D., Bert, J., Carlier, T., Comtat, C., Filipovic, M., Lamare, F., & Visvikis, D. (2018). CASToR: a generic data organization and processing code framework for multi-modal and multi-dimensional tomographic reconstruction. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/aadac1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.