Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 424

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography

Browne, J., de Pierro, A.B. · 1996 · IEEE Transactions on Medical Imaging

Abstract

The maximum likelihood (ML) approach to estimating the radioactive distribution in the body cross section has become very popular among researchers in emission computed tomography (ECT) since it has been shown to provide very good images compared to those produced with the conventional filtered backprojection (FBP) algorithm. The expectation maximization (EM) algorithm is an often-used iterative approach for maximizing the Poisson likelihood in ECT because of its attractive theoretical and practical properties. Its major disadvantage is that, due to its slow rate of convergence, a large amount of computation is often required to achieve an acceptable image. Here, the authors present a row-action maximum likelihood algorithm (RAMLA) as an alternative to the EM algorithm for maximizing the Poisson likelihood in ECT. The authors deduce the convergence properties of this algorithm and demonstrate by way of computer simulations that the early iterates of RAMLA increase the Poisson likelihood in ECT at an order of magnitude faster that the standard EM algorithm. Specifically, the authors show that, from the point of view of measuring total radionuclide uptake in simulated brain phantoms, iterations 1, 2, 3, and 4 of RAMLA perform at least as well as iterations 45, 60, 70, and 80, respectively, of EM. Moreover, the authors show that iterations 1, 2, 3, and 4 of RAMLA achieve comparable likelihood values as iterations 45, 60, 70, and 80, respectively, of EM. The authors also present a modified version of a recent fast ordered subsets EM (OS-EM) algorithm and show that RAMLA is a special case of this modified OS-EM. Furthermore, the authors show that their modification converges to a ML solution whereas the standard OS-EM does not.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/42.538946

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 38 references

Cited by

See all 424

Metadata

Authors
Browne, J., & de Pierro, A. B.
Venue
IEEE Transactions on Medical Imaging
Published
1996-10
Volume
15
Issue
5
Pages
687-699
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2130217200
Cited by
424
References
38
FWCI
7.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography. https://app.cochat.ai/papers/10.1109/42.538946
The paper
Browne, J., & de Pierro, A. B. (1996). A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.538946

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.