FLUKA particle therapy tool for Monte Carlo independent calculation of scanned proton and carbon ion beam therapy
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
While Monte Carlo (MC) codes are considered as the gold standard for dosimetric calculations, the availability of user friendly MC codes suited for particle therapy is limited. Based on the FLUKA MC code and its graphical user interface (GUI) Flair, we developed an easy-to-use tool which enables simple and reliable simulations for particle therapy. In this paper we provide an overview of functionalities of the tool and with the presented clinical, proton and carbon ion therapy examples we demonstrate its reliability and the usability in the clinical environment and show its flexibility for research purposes. The first, easy-to-use FLUKA MC platform for particle therapy with GUI functionalities allows a user with a minimal effort and reduced knowledge about MC details to apply MC at their facility and is expected to enhance the popularity of the MC for both research and clinical quality assurance and commissioning purposes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schneider, W., Bortfeld, T., & Schlegel, W. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/314 · Cited by 831
Cited by
Carante, M. P., Aricò, G., Ferrari, A., Kozlowska, W., Mairani, A., & Ballarini, F. (2019) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab490f · Cited by 23
Self-citationIn vivo validation of the BIANCA biophysical model: benchmarking against rat spinal cord RBE data
Carante, M. P., Aricò, G., Ferrari, A., Karger, C. P., Kozlowska, W., Mairani, A., Sala, P., & Ballarini, F. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21113973 · Cited by 21
Self-citationEmbriaco, A., Ramos, R., Carante, M., Ferrari, A., Sala, P., Vercesi, V., & Ballarini, F. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms221910877 · Cited by 13
Self-citation
Metadata
- Authors
- Kozłowska, W. S., Böhlen, T. T., Cuccagna, C., Ferrari, A., Fracchiolla, F., Magro, G., Mairani, A., Schwarz, M., Vlachoudis, V., & Georg, D.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2019-03-29
- Volume
- 64
- Issue
- 7
- Pages
- 075012
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2912378963
- Cited by
- 58
- References
- 1
- FWCI
- 4.78
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: FLUKA particle therapy tool for Monte Carlo independent calculation of scanned proton and carbon ion beam therapy. https://app.cochat.ai/papers/10.1088/1361-6560/ab02cb
- The paper
- Kozłowska, W. S., Böhlen, T. T., Cuccagna, C., Ferrari, A., Fracchiolla, F., Magro, G., Mairani, A., Schwarz, M., Vlachoudis, V., & Georg, D. (2019). FLUKA particle therapy tool for Monte Carlo independent calculation of scanned proton and carbon ion beam therapy. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/ab02cb
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.