A hierarchical deep reinforcement learning framework for intelligent automatic treatment planning of prostate cancer intensity modulated radiation therapy
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Purpose. We have previously proposed an intelligent automatic treatment planning (IATP) framework that builds a virtual treatment planner network (VTPN) to operate a treatment planning system (TPS) to generate high-quality radiation therapy (RT) treatment plans. While the potential of IATP in automating RT treatment planning has been demonstrated, its poor scalability caused by an almost linear growth of network size with the number of treatment planning parameters (TPPs) is a bottleneck, preventing its application in complicate, but clinically relevant treatment planning problems. The decision-making behavior of the trained network is hard to understand. Motivated by the decision-making process of a human planner, this study proposes a hierarchical IATP framework. Methods and materials. The hierarchical VTPN (HieVTPN) consists of three networks, i.e. Structure-Net, Parameter-Net, and Action-Net. When interacting with a TPS, the networks are employed in a sequential order in each step to decide the structure to adjust, the TPP to adjust for the selected structure, and the specific adjustment manner for the parameter, respectively. We developed an end-to-end hierarchical deep reinforcement learning scheme to simultaneously train the three networks. We then evaluated the effectiveness of the proposed framework in the treatment planning problems for prostate cancer intensity modulated RT (IMRT) and stereotactic body RT (SBRT). We benchmarked the performance of our approach by comparing plans made by VTPN of a parallel architecture, and the human plans submitted for competition in the 2016 American Association of Medical Dosimetrist (AAMD)/Radiosurgery Society (RSS) Plan Study. We analyzed scalability of the network size with respect to the number of TPPs. Numerical experiments were also performed to understand the rationale of the decision-making behaviors of the trained HieVTPN. Results. Both HieVTPNs for prostate IMRT and SBRT were trained successfully using 10 training patient cases and 5 validation cases. For IMRT, HieVTPN was able to generate high-quality plans for 59 testing patient cases that were not included in training process, achieving an average plan score of 8.62 (±0.83), with 9 being the maximal score. The score was comparable to that of the VTPN, 8.45 (±0.48). For SBRT planning, HieVTPN achieved an average plan score of 139.07 on five testing patient cases compared to the score of 132.21 averaged over the human plans summited for competition in AAMD/RSS plan study. Different from VTPN with network size linearly scaling with the number of TPPs, the network size of HieVTPN is almost independent of the number of TPPs. It was also observed that the decision-making behaviors of HieVTPN were understandable and generally agreed with the human experience. Conclusions. With the scalability and explainability, the hierarchical IATP framework is more favorable than the previous framework in terms of handling treatment planning problems involving a large number of TPPs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gradient-based learning applied to document recognition
Lecun, Y., Bottou, L., Bengio, Y., & Haffner, P. (1998) · Proceedings of the IEEE · doi:10.1109/5.726791 · Cited by 58,805 · cited 1×
“Such an optimization problem can be solved via the commonly used stochastic gradient descent algorithm (LeCun et al 1998).”
MethodAn Interpretable Planning Bot for Pancreas Stereotactic Body Radiation Therapy
Zhang, J., Wang, C., Sheng, Y., Palta, M., Czito, B., Willett, C., Zhang, J., Jensen, P. J., Yin, F.-F., Wu, Q., et al. (2021) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2020.10.019 · Cited by 41
Cited by
Deep reinforcement learning and its applications in medical imaging and radiation therapy: a survey
Xu, L., Zhu, S., & Wen, N. (2022) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ac9cb3 · Cited by 35
A feasibility study of automating radiotherapy planning with large language model agents
Wang, Q., Wang, Z., Li, M., Ni, X., Tan, R., Zhang, W., Wubulaishan, M., Wang, W., Yuan, Z., Zhang, Z., et al. (2025) · Physics in Medicine & Biology · doi:10.1088/1361-6560/adbff1 · Cited by 28
“Early DRL studies looked into using RL agent to automatically adjust dose fractionation protocols (Jalalimanesh et al 2017, Tseng et al 2017) and further explored automating hyper-parameter tuning during treatment planning optimization (Shen et al 2019, 2020, 2021).”
Maximizing impact of explainable artificial intelligence in radiotherapy: a critical review
Heising, L. M., Wolfs, C. J. A., Ou, C. X. J., Hoebers, F. J. P., van Limbergen, E. J., Verhaegen, F., & Jacobs, M. J. G. (2026) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ae25b2 · Cited by 2
Metadata
- Authors
- Shen, C., Chen, L., & Jia, X.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2021-06-23
- Volume
- 66
- Issue
- 13
- Pages
- 134002
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W3167305608
- Cited by
- 49
- References
- 2
- FWCI
- 4.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A hierarchical deep reinforcement learning framework for intelligent automatic treatment planning of prostate cancer intensity modulated radiation therapy. https://app.cochat.ai/papers/10.1088/1361-6560/ac09a2
- The paper
- Shen, C., Chen, L., & Jia, X. (2021). A hierarchical deep reinforcement learning framework for intelligent automatic treatment planning of prostate cancer intensity modulated radiation therapy. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/ac09a2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.