A robust deep convolutional neural network for the classification of abnormal cardiac rhythm using single lead electrocardiograms of variable length
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Atrial fibrillation (AF) is a major cause of hospitalization and death in the United States. Moreover, as the average age of individuals increases around the world, early detection and diagnosis of AF become even more pressing. In this paper, we introduce a novel deep learning architecture for the detection of normal sinus rhythm, AF, other abnormal rhythms, and noise. APPROACH: We have demonstrated through a systematic approach many hyperparameters, input sets, and optimization methods that yielded influence in both training time and performance accuracy. We have focused on these properties to identify an optimal 13-layer convolutional neural network (CNN) model which was trained on 8528 short single-lead ECG recordings and evaluated on a test dataset of 3658 recordings. MAIN RESULTS: -score of 0.83. SIGNIFICANCE: We have presented a robust deep learning-based architecture that can identify abnormal cardiac rhythms using short single-lead ECG recordings. The proposed architecture is computationally fast and can also be used in real-time cardiac arrhythmia detection applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×
“The Pan-Thompkins algorithm is one of the most widely used algorithms in detecting the QRS complex based on the digital analysis of slope, amplitude, and width (Pan and Tompkins 1985).”
MethodGo, A. S., Hylek, E. M., Phillips, K. A., Chang, Y., Henault, L. E., Selby, J. V., & Singer, D. E. (2001) · JAMA · doi:10.1001/jama.285.18.2370 · Cited by 6,205
Cited by
Automatic diagnosis of the 12-lead ECG using a deep neural network
Ribeiro, A. H., Ribeiro, M. H., Paixão, G. M. M., Oliveira, D. M., Gomes, P. R., Canazart, J. A., Ferreira, M. P. S., Andersson, C. R., Macfarlane, P. W., Meira, W., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-15432-4 · Cited by 894
Ribeiro, A. H., Ribeiro, M. H., Paixao, G. M., Oliveira, D. M., Gomes, P. R., Canazart, J. A., Ferreira, M. P. S., Andersson, C. R., Macfarlane, P. W., Meira, W., et al. (2020) · RePEc: Research Papers in Economics · doi:10.5281/zenodo.3625006 · Cited by 715
Hong, S., Zhou, Y., Shang, J., Xiao, C., & Sun, J. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103801 · Cited by 464
A review on deep learning methods for ECG arrhythmia classification
Ebrahimi, Z., Loni, M., Daneshtalab, M., & Gharehbaghi, A. (2020) · Expert Systems with Applications: X · doi:10.1016/j.eswax.2020.100033 · Cited by 447
Sun, T., Feng, B., Huo, J., Xiao, Y., Wang, W., Peng, J., Li, Z., Du, C., Wang, W., Zou, G., et al. (2024) · Nano-Micro Letters · doi:10.1007/s40820-023-01235-x · Cited by 384
Metadata
- Authors
- Kamaleswaran, R., Mahajan, R., & Akbilgic, O.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2018-03-27
- Volume
- 39
- Issue
- 3
- Pages
- 035006
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2790971290
- Cited by
- 105
- References
- 2
- FWCI
- 9.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.