CoChat

A comparison of probabilistic classifiers for sleep stage classification

Open access
Fonseca, Pedro, den Teuling, Niek, Long, Xi, Aarts, Ronald M · 2018 · Physiological Measurement
Cited by 39

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To compare conditional random fields (CRF), hidden Markov models (HMMs) and Bayesian linear discriminants (LDs) for cardiorespiratory sleep stage classification on a five-class sleep staging task (wake/N1/N2/N3/REM), to explore the benefits of incorporating time information in the classification and to evaluate the feasibility of sleep staging on obstructive sleep apnea (OSA) patients. APPROACH: The classifiers with and without time information were evaluated with 10-fold cross-validation on five-, four- (wake/N1 + N2/N3/REM) and three-class (wake/NREM/REM) classification tasks using a data set comprising 443 night-time polysomnography (PSG) recordings of 231 participants (180 healthy participants, 100 of which had a 'regular' sleep architecture, and 51 participants previously diagnosed with OSA). MAIN RESULTS: CRF with time information (CRFt) outperforms all other classifiers on all tasks, achieving a median accuracy and Cohen's κ for all participants of 62.8% and 0.44 for five classes, 68.8% and 0.47 for four classes, and 77.6% and 0.55 for three classes. An advantage was found in training classifiers, specifically for 'regular' and 'OSA' participants, achieving an improvement in classification performance for these groups. For 'regular' participants, CRFt achieved a median accuracy and Cohen's κ of 67.0% and 0.51, 70.8% and 0.53 and 81.3% and 0.62 for five-, four- and three-classes respectively, and for 'OSA' patients, of 59.9% and 0.40, 69.7% and 0.45, and 75.8% and 0.51 for five-, four- and three-classes respectively. SIGNIFICANCE: The results suggest that CRFt is not only better at learning and predicting more complex and irregular sleep architectures, but that it also performs reasonably well in five-class classification-the standard for sleep scoring used in clinical PSG. Additionally, and albeit with a decrease in performance when compared with healthy participants, sleep stage classification in OSA patients using cardiorespiratory features and CRFt seems feasible with reasonable accuracy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1361-6579/aabbc2

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 39

Metadata

Authors
Fonseca, P., den Teuling, N., Long, X., & Aarts, R. M.
Venue
Physiological Measurement
Published
2018-05-15
Volume
39
Issue
5
Pages
055001
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2796120867
Cited by
39
References
6
FWCI
3.56
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A comparison of probabilistic classifiers for sleep stage classification. https://app.cochat.ai/papers/10.1088/1361-6579/aabbc2
The paper
Fonseca, P., den Teuling, N., Long, X., & Aarts, R. M. (2018). A comparison of probabilistic classifiers for sleep stage classification. Physiological Measurement. https://doi.org/10.1088/1361-6579/aabbc2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.