CoChat

Fetal magnetocardiogram waveform characteristics

Open access
Strand, Sarah A, Strasburger, Janette F, Wakai, Ronald T · 2019 · Physiological Measurement
Cited by 33

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background : Fetal magnetocardiography (fMCG) is the most direct and precise method of assessing fetal rhythm and conduction. Although the utility of fMCG for evaluation of fetuses with serious arrhythmia is generally acknowledged, many aspects of fetal rhythm and conduction are relatively unstudied. Objective : To record fMCG in a large group of normal fetuses in order to provide a more comprehensive evaluation of fMCG waveform characteristics, including waveform intervals, amplitudes, and morphology. Methods : The subjects were 132 healthy women with uncomplicated singleton pregnancies, studied at 15.7–39.9 (mean 28.9) weeks’ gestation in 259 sessions. The P, PR, QRS, QT, QTc, and RR intervals and the P/QRS and T/QRS amplitude ratios were measured. Main results : The P, PR, QRS, and RR intervals increased with gestational age, but QT and QTc did not. U-waves were seen in 11% of fetuses. The T-waves were often flat with low T/QRS amplitude ratios. Equiphasic QRS complexes were associated with tall P-waves. The PR, QRS, and QT intervals showed a power law dependence on RR interval with power law exponents 0.445, 0.363, and 0.381, respectively. Significance : The data establish prediction intervals for fMCG waveform intervals and amplitudes in normal fetuses. This is critical for identification of fetuses with abnormal rhythm. Our study is the first to document the incidence of U-waves and flat T-waves in the fetus, both of which are uncommon postnatally. The association of tall P-waves with equiphasic QRS complexes provides a useful means of improving the resolution of fetal P-waves.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1361-6579/ab0a2c

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 33

Metadata

Authors
Strand, S. A., Strasburger, J. F., & Wakai, R. T.
Venue
Physiological Measurement
Published
2019-03-01
Volume
40
Issue
3
Pages
035002
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2918083245
Cited by
33
References
2
FWCI
2.77
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fetal magnetocardiogram waveform characteristics. https://app.cochat.ai/papers/10.1088/1361-6579/ab0a2c
The paper
Strand, S. A., Strasburger, J. F., & Wakai, R. T. (2019). Fetal magnetocardiogram waveform characteristics. Physiological Measurement. https://doi.org/10.1088/1361-6579/ab0a2c

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.