Deep learning approaches for plethysmography signal quality assessment in the presence of atrial fibrillation

Open access
Pereira, Tania, Ding, Cheng, Gadhoumi, Kais, Tran, Nate, Colorado, Rene A, Meisel, Karl, Hu, Xiao · 2019 · Physiological Measurement
Cited by 51

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Objective : Photoplethysmography (PPG) monitoring has been implemented in many portable and wearable devices we use daily for health and fitness tracking. Its simplicity and cost-effectiveness has enabled a variety of biomedical applications, such as continuous long-term monitoring of heart arrhythmias, fitness, and sleep tracking, and hydration monitoring. One major issue that can hinder PPG-based applications is movement artifacts, which can lead to false interpretations. In many implementations, noisy PPG signals are discarded. Misinterpreted or discarded PPG signals pose a problem in applications where the goal is to increase the yield of detecting physiological events, such as in the case of paroxysmal atrial fibrillation (AF)—a common episodic heart arrhythmia and a leading risk factor for stroke. In this work, we compared a traditional machine learning and deep learning approaches for PPG quality assessment in the presence of AF, in order to find the most robust method for PPG quality assessment. Approach : The training data set was composed of 78 278 30 s long PPG recordings from 3764 patients using bedside patient monitors. Two different representations of PPG signals were employed—a time-series based (1D) one and an image-based (2D) one. Trained models were tested on an independent set of 2683 30 s PPG signals from 13 stroke patients. Main results : ResNet18 showed a higher performance (0.985 accuracy, 0.979 specificity, and 0.988 sensitivity) than SVM and other deep learning approaches. 2D-based models were generally more accurate than 1D-based models. Significance : 2D representation of PPG signal enhances the accuracy of PPG signal quality assessment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1361-6579/ab5b84

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 51

Metadata

Authors
Pereira, T., Ding, C., Gadhoumi, K., Tran, N., Colorado, R. A., Meisel, K., & Hu, X.
Venue
Physiological Measurement
Published
2019-12-01
Volume
40
Issue
12
Pages
125002
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2990653535
Cited by
51
References
17
FWCI
1.99
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Deep learning approaches for plethysmography signal quality assessment in the presence of atrial fibrillation. https://app.cochat.ai/papers/10.1088/1361-6579/ab5b84
The paper
Pereira, T., Ding, C., Gadhoumi, K., Tran, N., Colorado, R. A., Meisel, K., & Hu, X. (2019). Deep learning approaches for plethysmography signal quality assessment in the presence of atrial fibrillation. Physiological Measurement. https://doi.org/10.1088/1361-6579/ab5b84

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.