Recording and quantifying fetal magnetocardiography signals using a flexible array of optically-pumped magnetometers
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Fetal magnetocardiography (fMCG) is a non-invasive biomagnetic technique that provides detailed beat-to-beat fetal heart rate analysis, both in normal rhythm as well as in fetal arrhythmias. New cryogenic-free sensors called optically pumped magnetometers (OPMs) have emerged as a less expensive and more geometrically flexible alternative to traditional Superconducting Quantum Interference Device (SQUID) technology for performing fMCG. The objective of the study was to show the ability of OPMs to record fMCG using flexible geometry while seeking to preserve signal quality, and to quantify fetal heart rate variability (FHRV). APPROACH: Biomagnetic measurements were performed with OPMs in 24 healthy pregnant women with uncomplicated singleton pregnancies between 28 and 38 weeks gestation (GA). A total of 96 recordings were analyzed from OPM data that was collected using sensors placed in two different maternal configurations over the abdomen. The fMCG signals were extracted and the quality of the recordings were quantified by peak amplitudes and signal-to-noise ratio (SNR). R peaks were used to perform both time and frequency domain FHRV analysis. FHRV measures obtained from OPMs were compared descriptively to the same measures obtained from GA-matched existing SQUID data. MAIN RESULTS: The fMCG derived from OPMs were observed in 21 of the 24 participants. Higher detection rates (85%) of fMCG signals were observed in the data sets recorded at GA >32 weeks. Peak amplitudes and SNR values were similar between two maternal configurations, but peak amplitudes were significantly higher (p = 0.013) in late GA compared to early GA. FHRV indicators were successfully extracted and their values overlapped substantially with those obtained from SQUID recordings. SIGNIFICANCE: Taking advantage of the geometric flexibility of the OPMs, we have demonstrated their ability to record and quantify fMCG in different maternal positions as opposed to rigid SQUID configurations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brainstorm: A User-Friendly Application for MEG/EEG Analysis
Tadel, F., Baillet, S., Mosher, J. C., Pantazis, D., & Leahy, R. M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/879716 · Cited by 3,677
Donofrio, M. T., Moon-Grady, A. J., Hornberger, L. K., Copel, J. A., Sklansky, M. S., Abuhamad, A., Cuneo, B. F., Huhta, J. C., Jonas, R. A., Krishnan, A., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437597.44550.5d · Cited by 1,275
Wavelet transforms and the ECG: a review
Addison, P. S. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/5/r01 · Cited by 908
Wavelet transform-based QRS complex detector
Kadambe, S., Murray, R., & Boudreaux-Bartels, G. F. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.771194 · Cited by 441 · cited 1×
“We detrended the fMCG data using a wavelet transform approach [16, 17].”
MethodARTiiFACT: a tool for heart rate artifact processing and heart rate variability analysis.
Kaufmann, T., Sütterlin, S., Schulz, S. M., & Vögele, C. (2011) · Behavior Research Methods · doi:10.3758/s13428-011-0107-7 · Cited by 284 · cited 1×
“As well, application of algorithms for robust artifact detection could enhance short-term FHRV [24].”
MethodOn-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
Iivanainen, J., Zetter, R., Grön, M., Hakkarainen, K., & Parkkonen, L. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.022 · Cited by 269
ECG artifacts and heart period variability: Don't miss a beat!
Berntson, G. G., & Stowell, J. R. (1998) · Psychophysiology · doi:10.1111/1469-8986.3510127 · Cited by 223 · cited 1×
“Irrespective of collection methodology, the missing beats can have a significant effect on short-term variability [23].”
BackgroundAlem, O., Sander, T. H., Mhaskar, R., LeBlanc, J., Eswaran, H., Steinhoff, U., Okada, Y., Kitching, J., Trahms, L., & Knappe, S. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/12/4797 · Cited by 182
Self-citationFetal heart rate variability and complexity in the course of pregnancy
Leeuwen, P. V., Lange, S., Bettermann, H., Grönemeyer, D. H. W., & Hatzmann, W. (1999) · Early Human Development · doi:10.1016/s0378-3782(98)00102-9 · Cited by 180 · cited 1×
“Temporal resolution of the QRS complex detection enables precise measurement of FHRV from R-R intervals [7].”
MethodAn estimate of fetal autonomic state by time-frequency analysis of fetal heart rate variability
David, M., Hirsch, M., Karin, J., Toledo, E., & AKSELROD, S. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00114.2006 · Cited by 163
Optical magnetometer array for fetal magnetocardiography
Wyllie, R., Kauer, M., Wakai, R. T., & Walker, T. G. (2012) · Optics Letters · doi:10.1364/ol.37.002247 · Cited by 148 · cited 1×
“[9] measured fMCG on a single fetus at 31 weeks gestation with a small static array of four OPMs followed by a recording using SQUID sensors with an interval of 10 minutes between sessions.”
MethodStrand, S., Lutter, W., Strasburger, J. F., Shah, V., Baffa, O., & Wakai, R. T. (2019) · Journal of the American Heart Association · doi:10.1161/jaha.119.013436 · Cited by 136
Compact long-term recorder for the transabdominal foetal and maternal electrocardiogram
Piéri, J. F., Crowe, J. A., Hayes‐Gill, B., Spencer, C., Bhogal, K., & James, D. K. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345275 · Cited by 119 · cited 1×
“Despite the fact that there have been several advances related to fetal electrocardiography, in comparison, fMCG still has superior signal-to-noise ratio (SNR) characteristics [3, 4].”
Background(1974) · Journal of Perinatal Medicine · doi:10.1515/jpme.1974.2.3.214 · Cited by 112
Antenatal fetal magnetocardiography: a new method for fetal surveillance?
Quinn, A., Weir, A. I., Shahani, U., Bain, R. J. P., Maas, P. M., & Donaldson, G. B. (1994) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1994.tb13547.x · Cited by 92 · cited 1×
“Currently, fMCG recordings rely on ultrasensitive SQUIDs that require cryogenics with a bulky dewar and a magnetically shielded room, leading to a high-cost device [8].”
BackgroundAdaptive rule based fetal QRS complex detection using hilbert transform
Uluşar, Ü. D., Govindan, R. B., Wilson, J. D., Lowery, C. L., Preissl, H. T., & Eswaran, H. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5334180 · Cited by 61 · cited 1×
“The R peaks of the fMCG traces were obtained via a peakdetection algorithm [18].”
MethodSelf-citationOn the fetal magnetocardiogram
Peters, M. J., Stinstra, J. G., van den Broek, S. P., Huirne, J. A. F., Quartero, H. W. F., ter Brake, H. J. M., & Rogalla, H. (1998) · Bioelectrochemistry and Bioenergetics · doi:10.1016/s0302-4598(98)00199-8 · Cited by 60
Lowery, C. L., Campbell, J. Q., Wilson, J. D., Murphy, P., Preissl, H. T., Malak, S. F., & Eswaran, H. (2003) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2003.367 · Cited by 51 · cited 4×
“Additionally, the goal was to quantify the OPM FHRV measures and perform a descriptive comparison to those obtained from an existing database of SQUID recordings in low-risk fetuses [12].”
MethodSelf-citationLimitations of antenatal fetal heart rate monitors
Dawes, G. S., Moulden, M., & Redman, C. W. G. (1990) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(90)90843-v · Cited by 47 · cited 1×
“Despite the fact that there have been several advances related to fetal electrocardiography, in comparison, fMCG still has superior signal-to-noise ratio (SNR) characteristics [3, 4].”
BackgroundKariniemi, V., Ahopelto, J., Karp, P. J., & Katila, T. E. (1974) · edoc Publication server (Humboldt University of Berlin) · doi:10.18452/12635 · Cited by 41
Eswaran, H., Escalona‐Vargas, D., Bolin, E. H., Wilson, J. D., & Lowery, C. L. (2016) · Prenatal Diagnosis · doi:10.1002/pd.4976 · Cited by 39
Self-citationDetection of Fetal Arrhythmia by Using Optically Pumped Magnetometers
Batie, M., Bitant, S., Strasburger, J. F., Shah, V., Alem, O., & Wakai, R. T. (2018) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2017.08.009 · Cited by 35
The normal magnetocardiogram: I Morphology.
Saarinen, M., SILTANEN, P., Karp, P., & Katila, T. E. (1978) · PubMed · Cited by 34
Mensah-Brown, N. A., Wakai, R. T., Cheulkar, B., Srinivasan, S., & Strasburger, J. F. (2010) · Fetal Diagnosis and Therapy · doi:10.1159/000318345 · Cited by 25 · cited 1×
“fMCG is shown to be capable of accurately and reliably detecting fetal heart rate (FHR) at gestational age (GA) greater than 17 weeks [5].”
MethodSeparation of Physiological Signals Using Minimum Norm Projection Operators
Wilson, J. D., & Haueisen, J. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2582643 · Cited by 17 · cited 1×
“To obtain the fMCG signal, the projection operator algorithm based on minimum norm (POMN) was applied to attenuate the maternal cardiac signals (mMCG) [13, 14].”
MethodA Comparison of Five Algorithms for Fetal Magnetocardiography Signal Extraction
Escalona‐Vargas, D., Wu, H., Frasch, M. G., & Eswaran, H. (2018) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-018-0351-4 · Cited by 11 · cited 1×
“To obtain the fMCG signal, the projection operator algorithm based on minimum norm (POMN) was applied to attenuate the maternal cardiac signals (mMCG) [13, 14].”
MethodSelf-citationGustafson, K. M., & Popescu, E. A. (2016) · Springer eBooks · doi:10.1007/978-3-319-22023-9_23 · Cited by 9 · cited 1×
“Fetal HR and HRV Metrics The metrics calculated for FHRV analysis [20] included:”
Method
Research works printed but not linked: 1
- Khandoker AH,, Poincaré plot methods for heart rate variability analysis. 2013: Springer.
Cited by
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Not with a “zap” but with a “beep”: Measuring the origins of perinatal experience
Frohlich, J., Bayne, T., Crone, J. S., Dallavecchia, A., Kirkeby-Hinrup, A., Mediano, P. A. M., Moser, J., Talar, K., Gharabaghi, A., & Preissl, H. T. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120057 · Cited by 38
Zhang, J., Liu, K., Zhang, J., Wang, Z., & Shang, J. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3120375 · Cited by 33
Design and Analysis of a High-Sensitivity Atomic Magnetic Gradiometer With Adjustable Baseline
Zhang, Y., Tang, J., Xu, X., Wang, Z., & Zhai, Y. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3544375 · Cited by 27
“Given that sensitivities and CMRRs can vary with frequency, the values reported in Table I represent average performance over the frequency band of interest for fMCG applications, which is approximately 1–100 Hz [38], [39].”
Wang, Y., Zhao, Z., Chai, Z., Fang, J., & Chen, M. (2023) · The FASEB Journal · doi:10.1096/fj.202300201rr · Cited by 27
“115 In particular, the shields and sensors utilized in the fetal MCG system can be adapted for use in the adult MCG system.”
Method
Metadata
- Authors
- Escalona-Vargas, D., Bolin, E. H., Lowery, C. L., Siegel, E. R., & Eswaran, H.
- Affiliations
- Arkansas Children's Hospital (US)
- University of Arkansas Medical Center (US)
- University of Arkansas for Medical Sciences (US)
- Corresponding author
- Eswaran, Hari
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2020-12-01
- Volume
- 41
- Issue
- 12
- Pages
- 125003
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- PMC
- PMC7875519
- OpenAlex
- W3093622789
- Cited by
- 26
- References
- 27
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 4 · 2023: 8 · 2022: 3 · 2021: 3
- FWCI
- 1.42
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor, 27 d)
- iopscience.iop.org/info/page/text-and-data-mining (tdm, 27 d)
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (1R21HD091744-01)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- fetal magnetocardiography, optically pumped magnetometers, fetal heart rate variability, SQUID comparison, maternal positioning, signal-to-noise ratio, fetal arrhythmia, fetal heart rate analysis
- MeSH terms
- Adolescent, Adult, Arrhythmias, Cardiac, Female, Gestational Age, Heart Rate, Fetal, Humans, Male, Pregnancy, Magnetocardiography, Young Adult, Signal-To-Noise Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.