CoChat

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Hollow cathode modeling: II. Physical analysis and parametric study

Open access
Sary, Gaétan, Garrigues, Laurent, Boeuf, Jean-Pierre · 2017 · Plasma Sources Science and Technology

Abstract

A numerical emissive hollow cathode model which couples plasma and thermal aspects of the NASA NSTAR cathode has been presented in a companion paper and simulation results obtained using the plasma model were compared to experimental data. We now compare simulation results with measurements using the full coupled model. Inside the cathode, the simulated plasma density profile agrees with the experimental data up to the ±50% experimental uncertainty while the simulated emitter temperature differs from measurements by at most 5 K. We then proceed to an analysis of the cathode discharge both inside the cathode where electron emission is dominant and outside in the near plume where electron transport instabilities are important. As observed previously in the literature, the total emitted electron current is much larger ( 34 A ) than the set discharge current collected at the anode ( 13 A ) while ionization plays a negligible role. Extracted electrons are emitted from a region much shorter than the full emitter ( 0.9 cm versus 2.5 cm ). The influence of an applied axial magnetic field in the plume is also assessed and we observe that it leads to a 10-fold increase of the plasma density 1 cm downstream of the orifice entrance while the simulated discharge potential at the anode is increased from 10 V up to 35.5 V . Lastly, we perform a parametric study on both the operating point (discharge current, mass flow rate) and design (inner radius) of the cathode. The simulated useful operating envelope is shown to be limited at low discharge current mostly because of the probable ion sputtering of the emitter and at high discharge current because of emitter evaporation, plasma oscillations and sputtering of the keeper electrode. The behavior of the cathode is also analyzed w.r.t. its internal radius and simulation results show that the useful emitter length scales linearly with the cathode radius.

Overview

Integrity signals

Registry

Crossref · 10.1088/1361-6595/aa6210

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 17 references

Cited by

See all 60

Metadata

Authors
Sary, G., Garrigues, L., & Boeuf, J.-P.
Affiliations
  • Centre National de la Recherche Scientifique (FR)
  • Université de Toulouse
Corresponding author
Sary, Gaétan
Venue
Plasma Sources Science and Technology
Published
2017-03-31
Volume
26
Issue
5
Pages
055008
ISSN
  • 0963-0252 (ISSN-L)
  • 1361-6595
OpenAlex
W2590730080
Cited by
57
References
17
Citations by year
2026: 5 · 2025: 2 · 2024: 7 · 2023: 8 · 2022: 7 · 2021: 6 · 2020: 10 · 2019: 8 · 2018: 1 · 2017: 3
FWCI
2.50
Type
journal article
Language
en
Open access
Licence
Locations
  • Plasma Sources Science and Technology (publishedVersion)
  • HAL (submittedVersion, other-oa)
Funders
Centre National d Etudes Spatiales (CNES-Snecma Ph.D. grant)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Low-Pressure Plasma Processing and Diagnostics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Vacuum and Plasma Arcs
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Gyrotron and Vacuum Electronics Research
Keywords
hollow cathode, NSTAR, electron emission, plasma density profile, emitter temperature, axial magnetic field, discharge potential, plasma oscillations, cathode design, parametric study

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hollow cathode modeling: II. Physical analysis and parametric study. https://app.cochat.ai/papers/10.1088/1361-6595/aa6210
The paper
Sary, G., Garrigues, L., & Boeuf, J.-P. (2017). Hollow cathode modeling: II. Physical analysis and parametric study. Plasma Sources Science and Technology. https://doi.org/10.1088/1361-6595/aa6210

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.