CoChat

Reduction of heating rate in a microfabricated ion trap by pulsed-laser cleaning

Open access
Allcock, D T C, Guidoni, L, Harty, T P, Ballance, C J, Blain, M G, Steane, A M, Lucas, D M · 2011 · New Journal of Physics
Cited by 63

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Laser cleaning of the electrodes in a planar micro-fabricated ion trap has been attempted using ns pulses from a tripled Nd:YAG laser at 355 nm.The effect of the laser pulses at several energy density levels has been tested by measuring the heating rate of a single 40 Ca + trapped ion as a function of its secular frequency ω z .A reduction of the electric-field noise spectral density by ∼50% has been observed and a change in the frequency dependence also noticed.This is the first reported experiment where the 'anomalous heating' phenomenon has been reduced by removing the source as opposed to reducing its thermal driving by cryogenic cooling.This technique may open up the way to better control of the electrode surface quality in ion microtraps.The recent success of quantum information experiments based on trapped ions [1] triggered research on micro-fabricated radio-frequency (Paul) traps, which are in principle able to fulfill the scalability requirement of a quantum computer [2,3].In such traps, a set of micro-fabricated conducting electrodes generates oscillating and static electric fields that trap laser-cooled ions in a harmonic potential well at a sub-millimeter distance d from the substrate [4,5].However, the presence of uncontrolled fluctuating electric fields affects the ions' external motion and induces an 'anomalous heating' that limits the achievable fidelity of multi-ion quantum gates that rely on the coherent control of this motion [6].Experimental observations concerning this phenomenon 4

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1367-2630/13/12/123023

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 63

Metadata

Authors
Allcock, D. T. C., Guidoni, L., Harty, T. P., Ballance, C. J., Blain, M. G., Steane, A. M., & Lucas, D. M.
Venue
New Journal of Physics
Published
2011-12-16
Volume
13
Issue
12
Pages
123023
ISSN
1367-2630 (ISSN-L)
OpenAlex
W2047905008
Cited by
63
References
3
FWCI
3.84
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reduction of heating rate in a microfabricated ion trap by pulsed-laser cleaning. https://app.cochat.ai/papers/10.1088/1367-2630/13/12/123023
The paper
Allcock, D. T. C., Guidoni, L., Harty, T. P., Ballance, C. J., Blain, M. G., Steane, A. M., & Lucas, D. M. (2011). Reduction of heating rate in a microfabricated ion trap by pulsed-laser cleaning. New Journal of Physics. https://doi.org/10.1088/1367-2630/13/12/123023

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.