Incoherent x-ray scattering in single molecule imaging
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Imaging of the structure of single proteins or other biomolecules with atomic resolution would be enormously beneficial to structural biology. X-ray free-electron lasers generate highly intense and ultrashort x-ray pulses, providing a route towards imaging of single molecules with atomic resolution. The information on molecular structure is encoded in the coherent x-ray scattering signal. In contrast to crystallography there are no Bragg reflections in single molecule imaging, which means the coherent scattering is not enhanced. Consequently, a background signal from incoherent scattering deteriorates the quality of the coherent scattering signal. This background signal cannot be easily eliminated because the spectrum of incoherently scattered photons cannot be resolved by usual scattering detectors. We present an ab initio study of incoherent x-ray scattering from individual carbon atoms, including the electronic radiation damage caused by a highly intense x-ray pulse. We find that the coherent scattering pattern suffers from a significant incoherent background signal at high resolution. For high x-ray fluence the background signal becomes even dominating. Finally, based on the atomic scattering patterns, we present an estimation for the average photon count in single molecule imaging at high resolution. By varying the photon energy from 3.5 keV to 15 keV, we find that imaging at higher photon energies may improve the coherent scattering signal quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
First lasing and operation of an ångstrom-wavelength free-electron laser
Emma, P., Akre, R., Arthur, J., Bionta, R., Bostedt, C., Bozek, J., Brachmann, A., Bucksbaum, P., Coffee, R., Decker, F.-J., et al. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.176 · Cited by 3,167
Potential for biomolecular imaging with femtosecond X-ray pulses
Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., & Hajdu, J. (2000) · Nature · doi:10.1038/35021099 · Cited by 2,022
Single mimivirus particles intercepted and imaged with an X-ray laser
Seibert, M. M., Ekeberg, T., Maia, F. R. N. C., Svenda, M., Andreasson, J., Jönsson, O., Odić, D., Iwan, B., Rocker, A., Westphal, D., et al. (2011) · Nature · doi:10.1038/nature09748 · Cited by 904
Femtosecond electronic response of atoms to ultra-intense X-rays
Young, L., Kanter, E. P., Krässig, B., Li, Y., March, A. M., Pratt, S. T., Santra, R., Southworth, S. H., Rohringer, N., DiMauro, L. F., et al. (2010) · Nature · doi:10.1038/nature09177 · Cited by 792
Self-citationNatively Inhibited Trypanosoma brucei Cathepsin B Structure Determined by Using an X-ray Laser
Redecke, L., Nass, K., DePonte, D. P., White, T. A., Rehders, D., Barty, A., Stellato, F., Liang, M., Barends, T. R. M., Boutet, S., et al. (2013) · Science · doi:10.1126/science.1229663 · Cited by 440
Multiwavelength Anomalous Diffraction at High X-Ray Intensity
Son, S.-K., Chapman, H. N., & Santra, R. (2011) · Physical Review Letters · doi:10.1103/physrevlett.107.218102 · Cited by 120
Self-citation
Cited by
Small-angle X-ray and neutron scattering
Jeffries, C. M., Ilavsky, J., Martel, A., Hinrichs, S., Meyer, A., Pedersen, J. S., Sokolova, A. V., & Svergun, D. I. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00064-9 · Cited by 256
The linac coherent light source single particle imaging road map
Aquila, A., Barty, A., Bostedt, C., Boutet, S., Carini, G., dePonte, D., Drell, P., Doniach, S., Downing, K. H., Earnest, T., et al. (2015) · Structural Dynamics · doi:10.1063/1.4918726 · Cited by 210
Self-citationJurek, Z., Son, S.-K., Ziaja, B., & Santra, R. (2016) · Journal of Applied Crystallography · doi:10.1107/s1600576716006014 · Cited by 103
“…cross section, (2) X-ray fluorescence rate, (3) Auger (Coster–Kronig) decay rate, (4) elastic X-ray scattering cross section and its dispersion correction (Son, Chapman & Santra, 2011), (5) Compton scattering cross section (Slowik et al., 2014), (6) shake-off branching ratio (Doumy et al., 2011).”
BackgroundSelf-citationNanoplasma Formation by High Intensity Hard X-rays
Tachibana, T., Jurek, Z., Fukuzawa, H., Motomura, K., Nagaya, K., Wada, S., Johnsson, P., Siano, M., Mondal, S., Ito, Y., et al. (2015) · Scientific Reports · doi:10.1038/srep10977 · Cited by 73
Self-citationAtomistic three-dimensional coherent x-ray imaging of nonbiological systems
Ho, P. J., Knight, C., Tegze, M., Faigel, G., Bostedt, C., & Young, L. (2016) · Physical Review A · doi:10.1103/physreva.94.063823 · Cited by 20
“Previous calculations on intense x-ray scattering from biomolecules consisting of mostly light elements (H, C, N, and O) demonstrate that the presence of Compton (inelastic) scattering can severely compromise the imaging resolution [34,35,74].”
Background
Metadata
- Authors
- Slowik, J. M., Son, S.-K., Dixit, G., Jurek, Z., & Santra, R.
- Venue
- New Journal of Physics
- Publisher
- IOP Publishing
- Published
- 2014-07-28
- Volume
- 16
- Issue
- 7
- Pages
- 073042
- ISSN
- 1367-2630 (ISSN-L)
- OpenAlex
- W2107755249
- Cited by
- 41
- References
- 6
- FWCI
- 7.43
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Incoherent x-ray scattering in single molecule imaging. https://app.cochat.ai/papers/10.1088/1367-2630/16/7/073042
- The paper
- Slowik, J. M., Son, S.-K., Dixit, G., Jurek, Z., & Santra, R. (2014). Incoherent x-ray scattering in single molecule imaging. New Journal of Physics. https://doi.org/10.1088/1367-2630/16/7/073042
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.