Optical biosensor microsystems based on the integration of highly sensitive Mach–Zehnder interferometer devices
Abstract
We present highly sensitive optical biosensors able to be fully integrated in lab-on-a-chip microsystems using standard CMOS compatible processes. These optical biosensors are based on integrated Mach–Zehnder interferometers, which have been designed to have high surface sensitivity and monomode behaviour. As a biosensing application of the devices we show the real-time detection of the covalent immobilization and hybridization of DNA strands without labelling. In order to achieve a lab-on-a-chip portable microsystem, we present the integration of the sensor with a CMOS compatible microfluidic system using SU-8 photolithography patterned layers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Plasmonic Biosensing: Focus Review
Mejía-Salazar, J. R., & Oliveira, O. N. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00359 · Cited by 544
Silicon Photonic Biosensors Using Label-Free Detection
Luan, E., Shoman, H., Ratner, D. M., Cheung, K. C., & Chrostowski, L. (2018) · Sensors · doi:10.3390/s18103519 · Cited by 379
Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteins
Choi, S., Goryll, M., Sin, L. Y. M., Wong, P. K., & Chae, J. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0638-8 · Cited by 270
Highly sensitive Mach–Zehnder interferometer biosensor based on silicon nitride slot waveguide
Liu, Q., Tu, X., Kim, K. W., Kee, J. S., Shin, Y., Han, K., Yoon, Y.-J., Lo, G.-Q., & Park, M. K. (2013) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.07.053 · Cited by 253
Biofunctionalization of Multiplexed Silicon Photonic Biosensors
Puumala, L. S., Grist, S. M., Morales, J. M., Bickford, J. R., Chrostowski, L., Shekhar, S., & Cheung, K. C. (2022) · Biosensors · doi:10.3390/bios13010053 · Cited by 55
Metadata
- Authors
- Sepúlveda, B., Río, J. S. D., Moreno, M., Blanco, F. J., Mayora, K., Domínguez, C., & Lechuga, L. M.
- Venue
- Journal of Optics A: Pure and Applied Optics
- Publisher
- IOP Publishing
- Published
- 2006-06-12
- Volume
- 8
- Issue
- 7
- Pages
- S561-S566
- ISSN
- 1464-4258 (ISSN-L)
- 1741-3567
- OpenAlex
- W1989242806
- Cited by
- 188
- References
- 0
- FWCI
- 11.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical biosensor microsystems based on the integration of highly sensitive Mach–Zehnder interferometer devices. https://app.cochat.ai/papers/10.1088/1464-4258/8/7/s41
- The paper
- Sepúlveda, B., Río, J. S. D., Moreno, M., Blanco, F. J., Mayora, K., Domínguez, C., & Lechuga, L. M. (2006). Optical biosensor microsystems based on the integration of highly sensitive Mach–Zehnder interferometer devices. Journal of Optics A: Pure and Applied Optics. https://doi.org/10.1088/1464-4258/8/7/s41
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.