Cited by 205Neuroscience and Neural EngineeringConducting polymers and applicationsUndergraduate Neuroscience Education and Research

A review on mechanical considerations for chronically-implanted neural probes

Open access
Lecomte, Aziliz, Descamps, Emeline, Bergaud, Christian·2018·Journal of Neural Engineering

Abstract

This review intends to present a comprehensive analysis of the mechanical considerations for chronically-implanted neural probes. Failure of neural electrical recordings or stimulation over time has shown to arise from foreign body reaction and device material stability. It seems that devices that match most closely with the mechanical properties of the brain would be more likely to reduce the mechanical stress at the probe/tissue interface, thus improving body acceptance. The use of low Young’s modulus polymers instead of hard substrates is one way to enhance this mechanical mimetism, though compliance can be achieved through a variety of means. The reduction of probe width and thickness in comparison to a designated length, the use of soft hydrogel coatings and the release in device tethering to the skull, can also improve device compliance. Paradoxically, the more compliant the device, the more likely it will fail during the insertion process in the brain. Strategies have multiplied this past decade to offer partial or temporary stiffness to the device to overcome this buckling effect. A detailed description of the probe insertion mechanisms is provided to analyze potential sources of implantation failure and the need for a mechanically-enhancing structure. This leads us to present an overview of the strategies that have been put in place over the last ten years to overcome buckling issues. Particularly, great emphasis is put on bioresorbable polymers and their assessment for neural applications. Finally, a discussion is provided on some of the key features for the design of mechanically-reliable, polymer-based next generation of chronic neuroprosthetic devices.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1741-2552/aa8b4f

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Matching tissue biomechanics improves longevity by addressing interface compromising factors such as the foreign body reaction, which can deteriorate the neural interface and isolate the nerve fibers through scarring.

    “This improves longevity by addressing interface compromising factors such as the foreign body reaction, which can deteriorate the neural interface and isolate the nerve fibers through scarring [12], [206].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 247 · Cited by 205

Research works printed but not linked: 1

  1. Das D, Zhang Z, Winkler T, Mour M, Gunter C I, Morlock M M, Machens H G and Schilling A F 2011 Bioresorption and degradation of biomaterials Tissue Engineering III: Cell -Surface Interactions for Tissue Culture. Advances in Biochemical Engineering Biotechnology vol 126, ed C Kasper, F Witte, R Pörtner (Berlin: Springer)

Authors
Lecomte, A., Descamps, E., & Bergaud, C.
Affiliations
  • Laboratoire d'Analyse et d'Architecture des Systèmes (FR)
  • Université de Toulouse
Venue
Journal of Neural Engineering
Published
2018-03-05
Volume
15
Issue
3
Pages
031001
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W2751178603
Cited by
205
References
247
Citations by year
2026: 20 · 2025: 26 · 2024: 27 · 2023: 18 · 2022: 24 · 2021: 30 · 2020: 27 · 2019: 20 · 2018: 13
FWCI
2.02
Type
journal article
Language
en
Open access
Locations
  • Journal of Neural Engineering (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • HAL (submittedVersion, other-oa)
Funders
  • University of Alberta
  • Agence Nationale de la Recherche (ANR-15-CE19-0006)
  • Centre National de la Recherche Scientifique
  • Institut des sciences de l'ingénierie et des systèmes
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Undergraduate Neuroscience Education and Research
Keywords
foreign body reaction, brain mechanical properties, device compliance, hydrogel coating, bioresorbable polymers, implantation failure
MeSH terms
Animals, Brain, Electrodes, Implanted, Equipment Design, Foreign-Body Reaction, Humans, Materials Testing, Microelectrodes, Polymers, Stress, Mechanical, Time Factors, Hydrogels

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review