The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
A generic EEG artifact removal algorithm based on the multi-channel Wiener filter
Open accessAbstract
OBJECTIVE: The electroencephalogram (EEG) is an essential neuro-monitoring tool for both clinical and research purposes, but is susceptible to a wide variety of undesired artifacts. Removal of these artifacts is often done using blind source separation techniques, relying on a purely data-driven transformation, which may sometimes fail to sufficiently isolate artifacts in only one or a few components. Furthermore, some algorithms perform well for specific artifacts, but not for others. In this paper, we aim to develop a generic EEG artifact removal algorithm, which allows the user to annotate a few artifact segments in the EEG recordings to inform the algorithm. APPROACH: We propose an algorithm based on the multi-channel Wiener filter (MWF), in which the artifact covariance matrix is replaced by a low-rank approximation based on the generalized eigenvalue decomposition. The algorithm is validated using both hybrid and real EEG data, and is compared to other algorithms frequently used for artifact removal. MAIN RESULTS: The MWF-based algorithm successfully removes a wide variety of artifacts with better performance than current state-of-the-art methods. SIGNIFICANCE: Current EEG artifact removal techniques often have limited applicability due to their specificity to one kind of artifact, their complexity, or simply because they are too 'blind'. This paper demonstrates a fast, robust and generic algorithm for removal of EEG artifacts of various types, i.e. those that were annotated as unwanted by the user.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
Haykin, S. (1986) · Cited by 12,603
Rogers, S. (1996) · Control Engineering Practice · doi:10.1016/0967-0661(96)82838-3 · Cited by 9,278
Fast and robust fixed-point algorithms for independent component analysis
Hyvarinen, A. (1999) · IEEE Transactions on Neural Networks · doi:10.1109/72.761722 · Cited by 6,246
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Optimal spatial filtering of single trial EEG during imagined hand movement
Ramoser, H., Muller-Gerking, J., & Pfurtscheller, G. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895946 · Cited by 2,457
(2002) · Cited by 1,481
ADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal features
Mognon, A., Jovicich, J., Bruzzone, L., & Buiatti, M. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01061.x · Cited by 1,290
EEG differences between eyes-closed and eyes-open resting conditions
Barry, R. J., Clarke, A. R., Johnstone, S. J., Magee, C. A., & Rushby, J. A. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.07.028 · Cited by 1,077
FASTER: Fully Automated Statistical Thresholding for EEG artifact Rejection
Nolan, H., Whelan, R., & Reilly, R. B. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.07.015 · Cited by 1,077
Scalp electrode impedance, infection risk, and EEG data quality
Ferree, T. C., Luu, P., Russell, G. S., & Tucker, D. M. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00533-2 · Cited by 1,005
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
xDAWN Algorithm to Enhance Evoked Potentials: Application to Brain–Computer Interface
Rivet, B., Souloumiac, A., Attina, V., & Gibert, G. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2012869 · Cited by 537 · cited 2×
“4The original xDAWN algorithm in [27] was based on a QR decomposition and a singular value decomposition, although it was later shown to be an instance of a GEVD filter in [28].”
MethodCanonical Correlation Analysis Applied to Remove Muscle Artifacts From the Electroencephalogram
Clercq, W. D., Vergult, A., Vanrumste, B., Van Paesschen, W., & Van Huffel, S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.879459 · Cited by 522
Metting van Rijn, A. C., Peper, A., & Grimbergen, C. A. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441666 · Cited by 450
High-quality recording of bioelectric events: Part 1 Interference reduction, theory and practice
Metting van Rijn, A. C., Peper, A., & Grimbergen, C. A. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441961 · Cited by 427
60-Hz Interference in Electrocardiography
Huhta, J. C., & Webster, J. G. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324169 · Cited by 412
GSVD-based optimal filtering for single and multimicrophone speech enhancement
Doclo, S., & Moonen, M. (2002) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2002.801937 · Cited by 379
Artifact Removal in Physiological Signals—Practices and Possibilities
Sweeney, K. T., Ward, T. E., & McLoone, S. F. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2188536 · Cited by 361
Joint decorrelation, a versatile tool for multichannel data analysis
de Cheveigné, A., & Parra, L. C. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.05.068 · Cited by 192
Denoising Source SeparationPreprint
Särelä, J., & Harri Valpola, B. (2005) · CogPrints (University of Southampton) · Cited by 162
Arnaud Delorme, A., Makeig, S., B, T. J. S. A., & Pines, N. T. (2001) · Cited by 154
Removal of Muscle Artifacts from EEG Recordings of Spoken Language Production
Vos, M. D., Riès, S., Vanderperren, K., Vanrumste, B., Alario, F. ‐., Huffel, V. S., & Burle, B. (2010) · Neuroinformatics · doi:10.1007/s12021-010-9071-0 · Cited by 142
Distributed Signal Processing for Wireless EEG Sensor Networks
Bertrand, A. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2418351 · Cited by 95
Self-citationSimultaneous ocular and muscle artifact removal from EEG data by exploiting diverse statistics
Chen, X., Liu, A., Chen, Q., Liu, Y., Zou, L., & McKeown, M. J. (2017) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.06.013 · Cited by 56
Rivet, B., & Souloumiac, A. (2012) · Signal Processing · doi:10.1016/j.sigpro.2012.07.019 · Cited by 44
EEG signal enhancement using multi-channel wiener filter with a spatial correlation prior
Maki, H., Toda, T., Sakti, S., Neubig, G., & Nakamura, S. (2015) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2015.7178449 · Cited by 27
Sardouie, S. H., Shamsollahi, M. B., Albera, L., & Merlet, I. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2336797 · Cited by 20
Multi-Channel Wiener Filtering Based Auditory Steady-State Response Detection
Dun, B. V., Wouters, J. M., & Moonen, M. (2007) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2007.366389 · Cited by 17
Cited by
Removal of Artifacts from EEG Signals: A Review
Jiang, X., Bian, G.-B., & Tian, Z. (2019) · Sensors · doi:10.3390/s19050987 · Cited by 826
Rashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
Perera, M. P. N., Mallawaarachchi, S., Bailey, N. W., Murphy, O. W., & Fitzgerald, P. B. (2023) · Psychological Medicine · doi:10.1017/s0033291723000843 · Cited by 18
Metadata
- Authors
- Somers, B., Francart, T., & Bertrand, A.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2018-02-27
- Volume
- 15
- Issue
- 3
- Pages
- 036007
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2790725051
- Cited by
- 255
- References
- 30
- FWCI
- 10.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.