Electric field measurement of two commercial active/sham coils for transcranial magnetic stimulation
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Objective . Sham TMS coils isolate the ancillary effects of their active counterparts but typically induce low-strength electric fields (E-fields) in the brain, which could be biologically active. We measured the E-fields induced by two pairs of commonly-used commercial active/sham coils. Approach . E-field distributions of the active and sham configurations of the Magstim 70 mm AFC and MagVenture Cool-B65 A/P coils were measured over a 7 cm-radius, hemispherical grid approximating the cortical surface. Peak E-field strength was recorded over a range of pulse amplitudes. Main results . The Magstim and MagVenture shams induce peak E-fields corresponding to 25.3% and 7.72% of their respective active values. The MagVenture sham has an E-field distribution shaped like its active counterpart. The Magstim sham induces nearly zero E-field under the coil’s center, and its peak E-field forms a diffuse oval 3–7 cm from the center. Electrical scalp stimulation paired with the MagVenture sham is estimated to increase the sham E-field in the brain up to 10%. Significance . Different commercial shams induce different E-field strengths and distributions in the brain, which should be considered in interpreting outcomes of sham stimulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“As suggested by Ref. [33], the induced significant electric field can produce low-field effects that affect neuromodulation.”
From Repetitive transcranial magnetic stimulation as a treatment for Alzheimer's disease: A randomized placebo-controlled double-blind clinical trial (2024) · cites this paper as [33]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Low-Field Magnetic Stimulation in Bipolar Depression Using an MRI-Based Stimulator
Rohan, M., Parow, A., Stoll, A. L., Demopulos, C., Friedman, S., Dager, S., Hennen, J., Cohen, B. M., & Renshaw, P. F. (2004) · American Journal of Psychiatry · doi:10.1176/appi.ajp.161.1.93 · Cited by 125
Rapid Mood-Elevating Effects of Low Field Magnetic Stimulation in Depression
Rohan, M. L., Yamamoto, R. T., Ravichandran, C. T., Cayetano, K. R., Morales, O. G., Olson, D. P., Vitaliano, G., Paul, S. M., & Cohen, B. M. (2014) · Biological Psychiatry · doi:10.1016/j.biopsych.2013.10.024 · Cited by 97
Research works printed but not linked: 16
- Duecker, 2015, Rethinking the role of sham TMS, Front. Psychol., 6, 210, 10.3389/fpsyg.2015.00210 · DOI · Paper page
- Davey, 2006, Suppressing the surface field during transcranial magnetic stimulation, IEEE Trans. Biomed. Eng., 53, 190, 10.1109/TBME.2005.862545 · DOI · Paper page
- Rossi, 2007, A real electro-magnetic placebo (REMP) device for sham transcranial magnetic stimulation (TMS), Clin. Neurophysiol., 118, 709, 10.1016/j.clinph.2006.11.005 · DOI
- Arana, 2008, Focal electrical stimulation as a sham control for repetitive transcranial magnetic stimulation: Does it truly mimic the cutaneous sensation and pain of active prefrontal repetitive transcranial magnetic stimulation?, Brain Stimul., 1, 44, 10.1016/j.brs.2007.08.006 · DOI
- Deng, 2011, Transcranial magnetic stimulation coil with electronically switchable active and sham modes, vol 2011, 1993, 10.1109/IEMBS.2011.6090561 · DOI
- Carlezon, 2005, Antidepressant-like effects of cranial stimulation within a low-energy magnetic field in rats, Biol. Psychiatry, 57, 571, 10.1016/j.biopsych.2004.12.011 · DOI
- Rohan, 2017, Sustained improvement in mood after 3 days of low field magnetic stimulation in subjects with bipolar depression, Biol. Psychiatry, 81, S260, 10.1016/j.biopsych.2017.02.1052 · DOI
- Martiny, 2010, Transcranial low voltage pulsed electromagnetic fields in patients with treatment-resistant depression, Biol. Psychiatry, 68, 163, 10.1016/j.biopsych.2010.02.017 · DOI
- Volkow, 2010, Effects of low-field magnetic stimulation on brain glucose metabolism, NeuroImage, 51, 623, 10.1016/j.neuroimage.2010.02.015 · DOI · Paper page
- Opitz, 2014, Is sham cTBS real cTBS? The effect on EEG dynamics, Frontiers Hum. Neurosci., 8, 1043, 10.3389/fnhum.2014.01043 · DOI · Paper page
- Nieminen, 2015, Experimental characterization of the electric field distribution induced by TMS devices, Brain Stimul., 8, 582, 10.1016/j.brs.2015.01.004 · DOI · Paper page
- Wang, 2018, Redesigning existing transcranial magnetic stimulation coils to reduce energy: application to low field magnetic stimulation, J. Neural Eng., 15, 10.1088/1741-2552/aaa505 · DOI
- Deng, 2013, Electric field depth-focality tradeoff in transcranial magnetic stimulation: simulation comparison of 50 coil designs, Brain Stimul., 6, 1, 10.1016/j.brs.2012.02.005 · DOI · Paper page
- Krieg, 2015, Computational and experimental analysis of TMS-induced electric field vectors critical to neuronal activation, J. Neural Eng., 12, 10.1088/1741-2560/12/4/046014 · DOI
- MagVenture, 2017, Cool-coil system: user manual, US
- Deng, 2013, Controlling stimulation strength and focality in electroconvulsive therapy via current amplitude and electrode size and spacing: comparison with magnetic seizure therapy, J. ECT, 29, 325, 10.1097/YCT.10.1097/YCT.0b013e3182a4b4a7 · doi:10.1097/yct
Cited by
Moretti, J., & Rodger, J. (2022) · Current Research in Neurobiology · doi:10.1016/j.crneur.2022.100033 · Cited by 60
“In addition, electric field measurements of some sham coils also show biologically relevant induced electric fields in the brain (Smith and Peterchev, 2018).”
BackgroundMethodMoussavi, Z., Uehara, M., Rutherford, G., Lithgow, B., Millikin, C., Wang, X., Saha, C., Mansouri, B., Omelan, C., Fellows, L., et al. (2024) · Neurotherapeutics · doi:10.1016/j.neurot.2024.e00331 · Cited by 52
Faerman, A., Bishop, J. H., Stimpson, K. H., Phillips, A., Gülser, M., Amin, H., Nejad, R., DeSouza, D. D., Geoly, A. D., Kallioniemi, E., et al. (2024) · Nature Mental Health · doi:10.1038/s44220-023-00184-z · Cited by 36
Metadata
- Authors
- Smith, J. E., & Peterchev, A. V.
- Affiliations
- Duke University
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2018-07-11
- Volume
- 15
- Issue
- 5
- Pages
- 054001
- ISSN
- 1741-2560
- 1741-2552
- Cited by
- 66
- References
- 2
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Funders
- National Institute of Mental Health (RF1MH114253)
- National Institute on Aging (U01AG050618)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electric field measurement of two commercial active/sham coils for transcranial magnetic stimulation. https://app.cochat.ai/papers/10.1088/1741-2552/aace89
- The paper
- Smith, J. E., & Peterchev, A. V. (2018). Electric field measurement of two commercial active/sham coils for transcranial magnetic stimulation. Journal of Neural Engineering. https://doi.org/10.1088/1741-2552/aace89