Suppressing the Surface Field During Transcranial Magnetic Stimulation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Transcranial magnetic stimulation (TMS) is used commonly as both a diagnostic tool and as an alternative to electric shock therapy for the treatment of clinical depression. Among the clinical issues encountered in its use is the mitigation of accompanying pain. The objective becomes one of minimizing the induced surface field while still achieving the target field objective. Three techniques discussed for realizing this end are 1) placing a conducting shield over a portion of the central target region, 2) using supplementary coils of opposite polarity in tandem with the primary field, and 3) opening the core angle to distribute the field. Option (3) shows the greatest promise for reducing the ratio of the maximum surface field to the induced target field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pascual-Leone, A., Rubio, B., Pallardó, F., & Catalá, M. D. (1996) · The Lancet · doi:10.1016/s0140-6736(96)01219-6 · Cited by 1,229
Cited by
Rossi, S., Hallett, M., Rossini, P. M., & Pascual-Leone, A. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.08.016 · Cited by 5,367
“…been tested ex vivo and in human subjects (Roth et al., 2002, 2007; Zangen et al., 2005), Other theoretical designs for deep brain TMS have been evaluated with computer simulations, such as stretched C-core coil (Davey and Riehl, 2006; Deng et al., 2008) and circular crown coil (Deng et al., 2008).”
BackgroundDeng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2013) · Brain Stimulation · doi:10.1016/j.brs.2012.02.005 · Cited by 1,073
Noninvasive Human Brain Stimulation
Wagner, T., Valero-Cabre, A., & Pascual-Leone, A. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.061206.133100 · Cited by 873
Coil design considerations for deep transcranial magnetic stimulation
Deng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.11.038 · Cited by 308
Wagner, T., Rushmore, J., Eden, U., & Valero-Cabre, A. (2009) · Cortex · doi:10.1016/j.cortex.2008.10.002 · Cited by 188
“To address these limitations, researchers are developing innovative coils and shielding devices to improve TMS focality (Carbunaru and Durand, 2001; Davey and Riehl, 2006).”
BackgroundMethod
Metadata
- Authors
- Davey, K. R., & Riehl, M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2006-02
- Volume
- 53
- Issue
- 2
- Pages
- 190-194
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2114080432
- Cited by
- 58
- References
- 1
- FWCI
- 1.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Suppressing the Surface Field During Transcranial Magnetic Stimulation. https://app.cochat.ai/papers/10.1109/tbme.2005.862545
- The paper
- Davey, K. R., & Riehl, M. (2006). Suppressing the Surface Field During Transcranial Magnetic Stimulation. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2005.862545
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.