Decoding motor neuron activity from epimysial thin-film electrode recordings following targeted muscle reinnervation
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Objective . Surface electromyography (EMG) is currently used as a control signal for active prostheses in amputees who underwent targeted muscle reinnervation (TMR) surgery. Recent research has shown that it is possible to access the spiking activity of spinal motor neurons from multi-channel surface EMG. In this study, we propose the use of multi-channel epimysial EMG electrodes as an interface for decoding motor neurons activity following TMR. Approach . We tested multi-channel epimysial electrodes (48 detection sites) built with thin-film technology in an animal model of TMR. Eight animals were tested 12 weeks after reinnervation of the biceps brachii lateral head by the ulnar nerve. We identified the position of the innervation zone and the muscle fiber conduction velocity of motor units decoded from the multi-channel epimysial recordings. Moreover, we characterized the pick-up volume by the distribution of the motor unit action potential amplitude over the epimysium surface. Main results . The electrodes provided high quality signals with average signal-to-noise ratio >30 dB across 95 identified motor units. The motor unit action potential amplitude decreased with increasing distance of the electrode from the muscle fibers ( P 0.001). The decrease was more pronounced for bipolar compared to monopolar derivations. The average muscle fiber conduction velocity was 2.46 ± 0.83 m s −1 . Most of the neuromuscular junctions were close to the region where the nerve was neurotized, as observed from the EMG recordings and imaging data. Significance . These results show that epimysial electrodes can be used for selective recordings of motor unit activities with a pick-up volume that included the entire muscle in the rat hindlimb. Epimysial electrodes can thus be used for detecting motor unit activity in muscles with specific fascicular territories associated to different functions following TMR surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In contrast, surface electrodes generally are more flexible,[364,369] whose morphology in the limited space between this epimysium and the skin is either 1D or 2D thin electrode layers[370,371] or very tiny electrodes (millimeter or even sub-millimeter level).[369,372]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [369]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Multichannel Blind Source Separation Using Convolution Kernel Compensation
Holobar, A., & Zazula, D. (2007) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2007.896108 · Cited by 648
Multi-channel intramuscular and surface EMG decomposition by convolutive blind source separation
Negro, F., Muceli, S., Castronovo, A. M., Holobar, A., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026027 · Cited by 647
Self-citationOrtiz-Catalan, M., Håkansson, B., & Brånemark, R. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008933 · Cited by 484 · cited 1×
“These problems may be solved by invasive solutions, which additionally provide superior signal quality (Ortiz-Catalan et al 2014).”
BackgroundKuiken, T. A., Miller, L. A., Lipschutz, R. D., Lock, B. A., Stubblefield, K., Marasco, P. D., Zhou, P., & Dumanian, G. A. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60193-7 · Cited by 482
Effects of muscle fiber type and size on EMG median frequency and conduction velocity
Kupa, E. J., Roy, S. H., Kandarian, S. C., & De Luca, C. J. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.79.1.23 · Cited by 458
Farina, D., Vujaklija, I., Sartori, M., Kapelner, T., Negro, F., Jiang, N., Bergmeister, K., Andalib, A., Principe, J., & Aszmann, O. C. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0025 · Cited by 359 · cited 3×
“While we have shown the clinical feasibility of this approach in humans using non-invasive muscle interfacing (Farina et al 2017b), the long-term vision is to chronically implant multi-channel EMG sensors into muscles to establish an interface that is robust over time, overcoming the several…”
BackgroundMethodSelf-citationEMGLAB: An interactive EMG decomposition program
McGill, K. C., Lateva, Z. C., & Marateb, H. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.05.015 · Cited by 317
The linear electrode array: a useful tool with many applications
Merletti, R., Farina, D., & Gazzoni, M. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00082-2 · Cited by 285
Self-citationCharacterization of Human Motor Units From Surface EMG Decomposition
Farina, D., & Holobar, A. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2498665 · Cited by 221
Self-citation
Research works printed but not linked: 1
- Dimitrov G, 1974, Electromyogr. Clin. Neurophysiol., 14, 423
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationWang, J., He, T., & Lee, C. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.104039 · Cited by 129
Materials for Implantable Surface Electrode Arrays: Current Status and Future Directions
Tringides, C. M., & Mooney, D. J. (2022) · Advanced Materials · doi:10.1002/adma.202107207 · Cited by 77
Analysis of Man-Machine Interfaces in Upper-Limb Prosthesis: A Review
Ribeiro, J. C. S., Mota, F., Cavalcante, T. D. S., Nogueira, I. C., Gondim, V. J. T., de Albuquerque, V. H. C., & de Alexandria, A. R. (2019) · Robotics · doi:10.3390/robotics8010016 · Cited by 72
Metadata
- Authors
- Muceli, S., Bergmeister, K. D., Hoffmann, K.-P., Aman, M., Vukajlija, I., Aszmann, O. C., & Farina, D.
- Affiliations
- Imperial College London (GB)
- Medical University of Vienna (AT)
- Fraunhofer Institute for Biomedical Engineering (DE)
- Corresponding author
- Farina, Dario
- ORCID
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2018-12-12
- Volume
- 16
- Issue
- 1
- Pages
- 016010
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2898814090
- Cited by
- 30
- References
- 32
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 4 · 2023: 4 · 2022: 3 · 2021: 11 · 2020: 3 · 2019: 2
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- creativecommons.org/licenses/by/3.0/ (vor)
- Locations
- Journal of Neural Engineering (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion, other-oa)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- Chalmers Research (Chalmers University of Technology) (submittedVersion)
- Spiral (Imperial College London) (submittedVersion, cc-by)
- Funders
- ERC Advanced Grant (DEMOVE/267888)
- Horizon 2020 Framework Programme (EXTEND/779982)
- ERC PoC (INTERSPINE/737570)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- targeted muscle reinnervation, thin film electrodes, surface electromyography, motor neuron activity, muscle fiber conduction velocity, neuromuscular junction, biceps brachii, rat hindlimb
- MeSH terms
- Action Potentials, Animals, Electrodes, Electromyography, Male, Motor Neurons, Nerve Regeneration, Neuromuscular Junction, Ulnar Nerve, Rats, Sprague-Dawley, Muscle, Skeletal, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Decoding motor neuron activity from epimysial thin-film electrode recordings following targeted muscle reinnervation. https://app.cochat.ai/papers/10.1088/1741-2552/aaed85
- The paper
- Muceli, S., Bergmeister, K. D., Hoffmann, K.-P., Aman, M., Vukajlija, I., Aszmann, O. C., & Farina, D. (2019). Decoding motor neuron activity from epimysial thin-film electrode recordings following targeted muscle reinnervation. Journal of Neural Engineering. https://doi.org/10.1088/1741-2552/aaed85
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.