Wireless microelectrode arrays for selective and chronically stable peripheral nerve stimulation for hindlimb movement
Open accessAbstract
Objective . Maximizing the stability of implanted neural interfaces will be critical to developing effective treatments for neurological and neuromuscular disorders. Our research aims to develop a stable neural interface using wireless communication and intrafascicular microelectrodes to provide highly selective stimulation of neural tissue. Approach . We implanted a wireless floating microelectrode array into the left sciatic nerve of six rats. Over a 38 week implantation period, we recorded stimulation thresholds and movements evoked at each implanted electrode. We also tracked each animal’s response to sensory stimuli and performance on two different walking tasks. Main results . Presence of the microelectrode array inside the sciatic nerve did not cause any obvious motor or sensory deficits in the hindlimb. Visible movement in the hindlimb was evoked by stimulating the sciatic nerve with currents as low as 4.1 µ A. Thresholds for most of the 96 electrodes we implanted were below 20 µ A, and predictable recruitment of plantar flexion and dorsiflexion was achieved by stimulating rat sciatic nerve with the intrafascicular microelectrode array. Further, motor recruitment patterns for each electrode did not change significantly throughout the study. Significance . Incorporating wireless communication and a low-profile neural interface facilitated highly stable motor recruitment thresholds and fine motor control in the hindlimb throughout an extensive 9.5 month assessment in rodent peripheral nerve. Results of this study indicate that use of the wireless device tested here could be extended to other applications requiring selective neural stimulation and chronic implantation.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Interfaces of peripheral nerves such as ultrasonic neural dust, StimDust, and NeuroTalk active Utah electrode array demonstrated good performance in monitoring and activating the sciatic nerve.
“Interfaces of the peripheral nerves such as the ultrasonic neural dust, StimDust, and the NeuroTalk active Utah electrode array demonstrated good performance in monitoring and activating the sciatic nerve [42], [52], [53].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [53]
The Methods (Device design and assembly) describe a wireless microelectrode array using the NeuroTalk interface, and the Main results report reliable activation of the rat sciatic nerve to evoke hindlimb movement. The paper does not demonstrate monitoring sciatic-nerve activity with that array; it reports stimulation and observation of movement. The other named interfaces are not evaluated in this paper. (LLM, conf=0.86)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 39 · Cited by 7
- Authors
- Frederick, R. A., Troyk, P. R., & Cogan, S. F.
- Affiliations
- The University of Texas at Dallas (US)
- Illinois Institute of Technology (US)
- Corresponding author
- Frederick, Rebecca A
- Troyk, Philip R
- Cogan, Stuart F
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2021-10-01
- Volume
- 18
- Issue
- 5
- Pages
- 056058
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC10685740
- OpenAlex
- W3202956118
- Cited by
- 7
- References
- 39
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 2 · 2022: 2
- FWCI
- 0.46
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (UH3NS095557)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- peripheral nerve stimulation, sciatic nerve, neural interfaces, stimulation threshold, motor unit recruitment, hindlimb movement, plantar flexion, dorsiflexion, rat model
- MeSH terms
- Animals, Electric Stimulation, Hindlimb, Microelectrodes, Movement, Sciatic Nerve, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review