CoChat

An in vitro model for investigating impedance changes with cell growth and electrical stimulation: implications for cochlear implants

Open access
Newbold, Carrie, Richardson, Rachael, Huang, Christie Q, Milojevic, Dusan, Cowan, Robert, Shepherd, Robert · 2004 · Journal of Neural Engineering
Cited by 111

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The impedance of stimulating electrodes used in cochlear implants and other neural prostheses often increases post-implantation, and is thought to be due to fibrous tissue encapsulation of the electrode array. Increased impedance results in higher power requirements to stimulate target neurons at set charge densities. We developed an in vitro model to investigate the electrode-tissue interface in a highly controlled environment. This model was tested using three cell types, with and without charge-balanced biphasic electrical stimulation. Under standard tissue culture conditions, a monolayer of cells was grown over the electrode surface. Electrode impedance increased in proportion to the extent of cell coverage of the electrode. Cell type was a significant factor in the amount of impedance increase, with kidney epithelial cells (MDCK) creating the greatest impedance, followed by dissociated rat skin fibroblasts and then macrophages (J774). The application of electrical stimulation to cell-covered electrodes caused impedance fluctuations similar to that seen in vivo, with a lowering of impedance immediately following stimulation, and a recovery to pre-stimulation levels during inactive periods. Examination of these electrodes suggests that the stimulation-induced impedance changes were due to the amount of cell cover over the electrodes. This in vitro technique accurately models the changes in impedance observed with neural prostheses in vivo, and shows the close relationship between impedance and tissue coverage adjacent to the electrode surface. We believe that this in vitro approach holds great promise to further our knowledge of the mechanisms contributing to electrode impedance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1741-2560/1/4/005

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 111

Metadata

Authors
Newbold, C., Richardson, R., Huang, C. Q., Milojevic, D., Cowan, R., & Shepherd, R.
Venue
Journal of Neural Engineering
Published
2004-12-01
Volume
1
Issue
4
Pages
218-227
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W1984048709
Cited by
111
References
1
FWCI
0.55
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An in vitro model for investigating impedance changes with cell growth and electrical stimulation: implications for cochlear implants. https://app.cochat.ai/papers/10.1088/1741-2560/1/4/005
The paper
Newbold, C., Richardson, R., Huang, C. Q., Milojevic, D., Cowan, R., & Shepherd, R. (2004). An in vitro model for investigating impedance changes with cell growth and electrical stimulation: implications for cochlear implants. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/1/4/005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.