CoChat

Engineering a multimodal nerve conduit for repair of injured peripheral nerve

Quigley, A F, Bulluss, K J, Kyratzis, I L B, Gilmore, K, Mysore, T, Schirmer, K S U, Kennedy, E L, O'Shea, M, Truong, Y B, Edwards, S L, Peeters, G, Herwig, P, Razal, J M, Campbell, T E, Lowes, K N, Higgins, M J, Moulton, S E, Murphy, M A, Cook, M J, Clark, G M, Wallace, G G, Kapsa, R M I · 2013 · Journal of Neural Engineering
Cited by 75

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Injury to nerve tissue in the peripheral nervous system (PNS) results in long-term impairment of limb function, dysaesthesia and pain, often with associated psychological effects. Whilst minor injuries can be left to regenerate without intervention and short gaps up to 2 cm can be sutured, larger or more severe injuries commonly require autogenous nerve grafts harvested from elsewhere in the body (usually sensory nerves). Functional recovery is often suboptimal and associated with loss of sensation from the tissue innervated by the harvested nerve. The challenges that persist with nerve repair have resulted in development of nerve guides or conduits from non-neural biological tissues and various polymers to improve the prognosis for the repair of damaged nerves in the PNS. This study describes the design and fabrication of a multimodal controlled pore size nerve regeneration conduit using polylactic acid (PLA) and (PLA):poly(lactic-co-glycolic) acid (PLGA) fibers within a neurotrophin-enriched alginate hydrogel. The nerve repair conduit design consists of two types of PLGA fibers selected specifically for promotion of axonal outgrowth and Schwann cell growth (75:25 for axons; 85:15 for Schwann cells). These aligned fibers are contained within the lumen of a knitted PLA sheath coated with electrospun PLA nanofibers to control pore size. The PLGA guidance fibers within the nerve repair conduit lumen are supported within an alginate hydrogel impregnated with neurotrophic factors (NT-3 or BDNF with LIF, SMDF and MGF-1) to provide neuroprotection, stimulation of axonal growth and Schwann cell migration. The conduit was used to promote repair of transected sciatic nerve in rats over a period of 4 weeks. Over this period, it was observed that over-grooming and self-mutilation (autotomy) of the limb implanted with the conduit was significantly reduced in rats implanted with the full-configuration conduit compared to rats implanted with conduits containing only an alginate hydrogel. This indicates return of some feeling to the limb via the fully-configured conduit. Immunohistochemical analysis of the implanted conduits removed from the rats after the four-week implantation period confirmed the presence of myelinated axons within the conduit and distal to the site of implantation, further supporting that the conduit promoted nerve repair over this period of time. This study describes the design considerations and fabrication of a novel multicomponent, multimodal bio-engineered synthetic conduit for peripheral nerve repair.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1741-2560/10/1/016008

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 75

Metadata

Authors
Quigley, A. F., Bulluss, K. J., Kyratzis, I. L. B., Gilmore, K., Mysore, T., Schirmer, K. S. U., Kennedy, E. L., O'Shea, M., Truong, Y. B., Edwards, S. L., Peeters, G., Herwig, P., Razal, J. M., Campbell, T. E., Lowes, K. N., Higgins, M. J., Moulton, S. E., Murphy, M. A., Cook, M. J., Clark, G. M., Wallace, G. G., & Kapsa, R. M. I.
Venue
Journal of Neural Engineering
Published
2013-01-03
Volume
10
Issue
1
Pages
016008
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W1986780297
Cited by
75
References
3
FWCI
2.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Engineering a multimodal nerve conduit for repair of injured peripheral nerve. https://app.cochat.ai/papers/10.1088/1741-2560/10/1/016008
The paper
Quigley, A. F., Bulluss, K. J., Kyratzis, I. L. B., Gilmore, K., Mysore, T., Schirmer, K. S. U., Kennedy, E. L., O'Shea, M., Truong, Y. B., Edwards, S. L., Peeters, G., Herwig, P., Razal, J. M., Campbell, T. E., Lowes, K. N., Higgins, M. J., Moulton, S. E., Murphy, M. A., Cook, M. J., . . . Kapsa, R. M. I. (2013). Engineering a multimodal nerve conduit for repair of injured peripheral nerve. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/10/1/016008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.