Engineering a multimodal nerve conduit for repair of injured peripheral nerve
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Injury to nerve tissue in the peripheral nervous system (PNS) results in long-term impairment of limb function, dysaesthesia and pain, often with associated psychological effects. Whilst minor injuries can be left to regenerate without intervention and short gaps up to 2 cm can be sutured, larger or more severe injuries commonly require autogenous nerve grafts harvested from elsewhere in the body (usually sensory nerves). Functional recovery is often suboptimal and associated with loss of sensation from the tissue innervated by the harvested nerve. The challenges that persist with nerve repair have resulted in development of nerve guides or conduits from non-neural biological tissues and various polymers to improve the prognosis for the repair of damaged nerves in the PNS. This study describes the design and fabrication of a multimodal controlled pore size nerve regeneration conduit using polylactic acid (PLA) and (PLA):poly(lactic-co-glycolic) acid (PLGA) fibers within a neurotrophin-enriched alginate hydrogel. The nerve repair conduit design consists of two types of PLGA fibers selected specifically for promotion of axonal outgrowth and Schwann cell growth (75:25 for axons; 85:15 for Schwann cells). These aligned fibers are contained within the lumen of a knitted PLA sheath coated with electrospun PLA nanofibers to control pore size. The PLGA guidance fibers within the nerve repair conduit lumen are supported within an alginate hydrogel impregnated with neurotrophic factors (NT-3 or BDNF with LIF, SMDF and MGF-1) to provide neuroprotection, stimulation of axonal growth and Schwann cell migration. The conduit was used to promote repair of transected sciatic nerve in rats over a period of 4 weeks. Over this period, it was observed that over-grooming and self-mutilation (autotomy) of the limb implanted with the conduit was significantly reduced in rats implanted with the full-configuration conduit compared to rats implanted with conduits containing only an alginate hydrogel. This indicates return of some feeling to the limb via the fully-configured conduit. Immunohistochemical analysis of the implanted conduits removed from the rats after the four-week implantation period confirmed the presence of myelinated axons within the conduit and distal to the site of implantation, further supporting that the conduit promoted nerve repair over this period of time. This study describes the design considerations and fabrication of a novel multicomponent, multimodal bio-engineered synthetic conduit for peripheral nerve repair.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neurotrophins: Roles in Neuronal Development and Function
Huang, E. J., & Reichardt, L. F. (2001) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.24.1.677 · Cited by 4,394
Polypyrrole-coated electrodes for the delivery of charge and neurotrophins to cochlear neurons
Richardson, R. T., Wise, A. K., Thompson, B. C., Flynn, B. O., Atkinson, P. J., Fretwell, N. J., Fallon, J. B., Wallace, G. G., Shepherd, R. K., Clark, G. M., et al. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.01.015 · Cited by 304
Self-citationRichardson, R. T., Thompson, B., Moulton, S., Newbold, C., Lum, M. G., Cameron, A., Wallace, G., Kapsa, R., Clark, G., & O’Leary, S. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.09.008 · Cited by 251
Self-citation
Cited by
Vijayavenkataraman, S. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.02.003 · Cited by 556
Modern Trends for Peripheral Nerve Repair and Regeneration: Beyond the Hollow Nerve Guidance Conduit
Carvalho, C. R., Oliveira, J. M., & Reis, R. L. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00337 · Cited by 297
Peripheral Nerve Conduit: Materials and Structures
Houshyar, S., Bhattacharyya, A., & Shanks, R. (2019) · ACS Chemical Neuroscience · doi:10.1021/acschemneuro.9b00203 · Cited by 215
Gaudin, R., Knipfer, C., Henningsen, A., Smeets, R., Heiland, M., & Hadlock, T. (2016) · BioMed Research International · doi:10.1155/2016/3856262 · Cited by 207
“Luminal fillers are growth guidance scaffolds in the lumen of the conduit that have been shown to be favorable in nerve repair [62, 140].”
BackgroundDavachi, S. M., & Kaffashi, B. (2015) · Polymer-Plastics Technology and Engineering · doi:10.1080/03602559.2014.979507 · Cited by 156
“Application of prepared scaffolds showed a patent sciatic nerve proximal and distal to the nerve repair conduit implantation site after the 4-week implantation period, especially in animals with conduits containing the fully configured neuromatrix([113]).”
Background
Metadata
- Authors
- Quigley, A. F., Bulluss, K. J., Kyratzis, I. L. B., Gilmore, K., Mysore, T., Schirmer, K. S. U., Kennedy, E. L., O'Shea, M., Truong, Y. B., Edwards, S. L., Peeters, G., Herwig, P., Razal, J. M., Campbell, T. E., Lowes, K. N., Higgins, M. J., Moulton, S. E., Murphy, M. A., Cook, M. J., Clark, G. M., Wallace, G. G., & Kapsa, R. M. I.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2013-01-03
- Volume
- 10
- Issue
- 1
- Pages
- 016008
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1986780297
- Cited by
- 75
- References
- 3
- FWCI
- 2.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Engineering a multimodal nerve conduit for repair of injured peripheral nerve. https://app.cochat.ai/papers/10.1088/1741-2560/10/1/016008
- The paper
- Quigley, A. F., Bulluss, K. J., Kyratzis, I. L. B., Gilmore, K., Mysore, T., Schirmer, K. S. U., Kennedy, E. L., O'Shea, M., Truong, Y. B., Edwards, S. L., Peeters, G., Herwig, P., Razal, J. M., Campbell, T. E., Lowes, K. N., Higgins, M. J., Moulton, S. E., Murphy, M. A., Cook, M. J., . . . Kapsa, R. M. I. (2013). Engineering a multimodal nerve conduit for repair of injured peripheral nerve. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/10/1/016008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.