A fast, robust algorithm for power line interference cancellation in neural recording
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Power line interference may severely corrupt neural recordings at 50/60 Hz and harmonic frequencies. The interference is usually non-stationary and can vary in frequency, amplitude and phase. To retrieve the gamma-band oscillations at the contaminated frequencies, it is desired to remove the interference without compromising the actual neural signals at the interference frequency bands. In this paper, we present a robust and computationally efficient algorithm for removing power line interference from neural recordings. APPROACH: The algorithm includes four steps. First, an adaptive notch filter is used to estimate the fundamental frequency of the interference. Subsequently, based on the estimated frequency, harmonics are generated by using discrete-time oscillators, and then the amplitude and phase of each harmonic are estimated by using a modified recursive least squares algorithm. Finally, the estimated interference is subtracted from the recorded data. MAIN RESULTS: The algorithm does not require any reference signal, and can track the frequency, phase and amplitude of each harmonic. When benchmarked with other popular approaches, our algorithm performs better in terms of noise immunity, convergence speed and output signal-to-noise ratio (SNR). While minimally affecting the signal bands of interest, the algorithm consistently yields fast convergence (<100 ms) and substantial interference rejection (output SNR >30 dB) in different conditions of interference strengths (input SNR from -30 to 30 dB), power line frequencies (45-65 Hz) and phase and amplitude drifts. In addition, the algorithm features a straightforward parameter adjustment since the parameters are independent of the input SNR, input signal power and the sampling rate. A hardware prototype was fabricated in a 65 nm CMOS process and tested. Software implementation of the algorithm has been made available for open access at https://github.com/mrezak/removePLI. SIGNIFICANCE: The proposed algorithm features a highly robust operation, fast adaptation to interference variations, significant SNR improvement, low computational complexity and memory requirement and straightforward parameter adjustment. These features render the algorithm suitable for wearable and implantable sensor applications, where reliable and real-time cancellation of the interference is desired.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939 · cited 1×
“Keywords: power line interference, 50 or 60 Hz noise, adaptive filtering, gamma-band oscillations, extracellular neural recording, electroencephalography, electrocorticography (Some figures may appear in colour only in the online journal)”
BackgroundIntracellular Correlates of Fast (>200 Hz) Electrical Oscillations in Rat Somatosensory Cortex
Jones, M. S., MacDonald, K. D., Choi, B., Dudek, F. E., & Barth, D. S. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.3.1505 · Cited by 184
Cited by
Tutorial. Surface EMG detection, conditioning and pre-processing: Best practices
Merletti, R., & Cerone, G. L. (2020) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2020.102440 · Cited by 233
Signal Artifacts and Techniques for Artifacts and Noise Removal
Islam, M. K., Rastegarnia, A., & Sanei, S. (2021) · Intelligent Systems Reference Library · doi:10.1007/978-3-030-54932-9_2 · Cited by 54
Kim, K., Ladenbauer, J., Babo-Rebelo, M., Buot, A., Lehongre, K., Adam, C., Hasboun, D., Lambrecq, V., Navarro, V., Ostojic, S., et al. (2019) · The Journal of Neuroscience · doi:10.1523/jneurosci.2291-18.2019 · Cited by 39
“2 indicates inconclusive evidence for or against the null hypothesis (Kass and Raftery, 1995).”
BackgroundInfluentialXu, J., Nguyen, A. T., Wu, T., Zhao, W., Luu, D. K., & Yang, Z. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2972013 · Cited by 29
Self-citation
Metadata
- Authors
- Keshtkaran, M. R., & Yang, Z.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-03-24
- Volume
- 11
- Issue
- 2
- Pages
- 026017
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1995192822
- Cited by
- 64
- References
- 2
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A fast, robust algorithm for power line interference cancellation in neural recording. https://app.cochat.ai/papers/10.1088/1741-2560/11/2/026017
- The paper
- Keshtkaran, M. R., & Yang, Z. (2014). A fast, robust algorithm for power line interference cancellation in neural recording. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/11/2/026017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.