The role of muscle synergies in myoelectric control: trends and challenges for simultaneous multifunction control
Open accessThe DOI matches its Crossref record; 262 of the 262 references it cites were found in a registry or an index.
Abstract
Myoelectric control is filled with potential to significantly change human-robot interaction due to the ability to non-invasively measure human motion intent. However, current control schemes have struggled to achieve the robust performance that is necessary for use in commercial applications. As demands in myoelectric control trend toward simultaneous multifunctional control, multi-muscle coordinations, or synergies, play larger roles in the success of the control scheme. Detecting and refining patterns in muscle activations robust to the high variance and transient changes associated with surface electromyography is essential for efficient, user-friendly control. This article reviews the role of muscle synergies in myoelectric control schemes by dissecting each component of the scheme with respect to associated challenges for achieving robust simultaneous control of myoelectric interfaces. Electromyography recording details, signal feature extraction, pattern recognition and motor learning based control schemes are considered, and future directions are proposed as steps toward fulfilling the potential of myoelectric control in clinically and commercially viable applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–262 of 262
Inter-session variability modelling and joint factor analysis for face authentication
Wallace, R., McLaren, M., McCool, C., & Marcel, S. (2011) · doi:10.1109/ijcb.2011.6117599 · Cited by 61 · cited 1×
“fields such as machine learning [245], face recognition [246],”
BackgroundCreating new functional circuits for action via brain-machine interfaces
Orsborn, A. L., & Carmena, J. M. (2013) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2013.00157 · Cited by 59
Independent Component Analysis of High-Density Electromyography in Muscle Force Estimation
Staudenmann, D., Daffertshofer, A., Kingma, I., Stegeman, D. F., & van Dieën, J. H. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889202 · Cited by 59 · cited 5×
“Independent component analysis (ICA) [88] and spatio-temporal filters [89–92] are capable of extracting individual muscle activities from sEMG signals to separate cross-talk as well as any interference from other electrophysiological signals [100].”
BackgroundInfluentialEMG signals based gait phases recognition using hidden Markov models
Meng, M., She, Q., Gao, Y., & Luo, Z. (2010) · IEEE International Conference on Information and Automation (ICIA) · doi:10.1109/icinfa.2010.5512456 · Cited by 58 · cited 1×
“also prevent unnatural transitions between outputs [132].”
High-density EMG E-Textile systems for the control of active prostheses
Farina, D., Lorrain, T., Negro, F., & Jiang, N. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627455 · Cited by 57 · cited 1×
“Both Farina et al [278] and Assad et al [279] incorporate HDsEMG into a sleeve that can be worn by users, with preliminary results also showing high classification accuracies, but neither have yet to undergo extensive testing for real-time control schemes.”
BackgroundSimultaneous, Proportional, Multi-axis Prosthesis Control using Multichannel Surface EMG
Yatsenko, D., McDonnall, D., & Guillory, K. S. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353749 · Cited by 54 · cited 3×
“Yatsenko et al [176] use a variation of PCA to detect orthonormalized principal bases”
MethodFeature-based classification of myoelectric signals using artificial neural networks
Gallant, P. J., Morin, E. L., & Peppard, L. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02523219 · Cited by 52 · cited 1×
“Self organizing feature maps create nonlinear projections of EMG features to obtain task-specific synergies [112, 182, 183].”
BackgroundEffect of spatial filtering on crosstalk reduction in surface EMG recordings
Mesin, L., Smith, S. T., Hugo, S., et al. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.05.006 · Cited by 52 · cited 2×
“Large electrodes and/or multiple recording sites per muscle may also reduce the effects and extract robust signals without requiring ideal placement [75, 80, 81, 85, 86].”
BackgroundFarina, D., Rehbaum, H., Holobar, A., Vujaklija, I., Jiang, N., Hofer, C., Salminger, S., van Vliet, H.-W., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2306000 · Cited by 51
Liu, X., & Scheidt, R. A. (2008) · Journal of Neurophysiology · doi:10.1152/jn.01044.2007 · Cited by 50
Multi run ICA and surface EMG based signal processing system for recognising hand gestures
Naik, G. R., Kumar, D., & Palaniswami, M. S. (2008) · IEEE International Conference on Computer and Information Technology (CIT) · doi:10.1109/cit.2008.4594760 · Cited by 49 · cited 2×
“Naik et al [187] effectively train seven SVMs to classify all combinations of wrist and grouped finger flexions.”
MethodControl of multifunction myoelectric hand using a real-time EMG pattern recognition
Chu, J., Moon, I., Kim, S.-K., & Mun, M.-S. (2005) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2005.1545586 · Cited by 48 · cited 1×
“Self organizing feature maps create nonlinear projections of EMG features to obtain task-specific synergies [112, 182, 183].”
BackgroundReal-time Learning Method for Adaptable Motion-Discrimination using Surface EMG Signal
Kato, R., Yokoi, H., & Arai, T. (2006) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2006.282492 · Cited by 48 · cited 1×
“Unsupervised adaptation techniques provide themselves with feedback based on predictions, and were proposed by Kato et al [235] and Chen et al [236].”
MethodProc. 2004 IEEE Int. Conf. on Robotics and Automation (ICRA'2004)
Khawaja, K., Althoefer, K. A., Clode, M. P., & Seneviratne, L. D. (2004) · Cited by 48
Hargrove, L., Zhou, P., Englehart, K., & Kuiken, T. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2010392 · Cited by 47
Miller, L. A., & Swanson, S. (2009) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0b013e3181ae974d · Cited by 46 · cited 1×
“The Assessment for Capacity of Myoelectric Control define a set of observational performance metrics, measuring naturalness, spontaneity and compensatory motions [272].”
BackgroundSynergy matrices to estimate fluid wrist movements by surface electromyography
Choi, C., & Kim, J. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.02.006 · Cited by 40 · cited 1×
“Similar to LDA, NMF is also used directly in the control scheme to provide simultaneous control [43, 45].”
MethodMuceli, S., Jiang, N., & Farina, D. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627622 · Cited by 40 · cited 1×
“Networks can be trained with continuous outputs representing either force [178] or kinematics [175, 209].”
BackgroundKiguchi, K., & Quan, Q.-L. (2008) · 2008 IEEE International Conference on Fuzzy Systems (IEEE World Congress on Computational Intelligence) · doi:10.1109/fuzzy.2008.4630520 · Cited by 40 · cited 1×
“Kiguchi and Quan [239] propose an adaptive neuro-fuzzy controller to train an exoskeleton, where force sensors on the tip of the exoskeleton are used to update the model at different postures.”
MethodAn approach to surface EMG decomposition based on higher-order cumulants
Zazula, D., & Holobar, A. (2005) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(05)80006-9 · Cited by 38
Drost, G., Stegeman, D. F., Schillings, M. L., Horemans, H. L. D., Janssen, H. M. H. A., Massa, M., Nollet, F., & Zwarts, M. J. (2004) · Muscle & Nerve · doi:10.1002/mus.20104 · Cited by 38
Burkholder, T. J., & van Antwerp, K. W. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0983-8 · Cited by 37 · cited 1×
“Moreover, muscle synergies have only recently been recognized as influential components in control schemes [40, 50, 51, 63], and few techniques explicitly utilize them in the scheme [41–45, 47–49].”
MethodTeleimpedance control of a synergy-driven anthropomorphic hand
Ajoudani, A., Godfrey, S. B., Catalano, M. G., Grioli, G., Tsagarakis, N. G., & Bicchi, A. (2013) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2013.6696620 · Cited by 36
Delis, I., Berret, B., Pozzo, T., & Panzeri, S. (2013) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2013.00054 · Cited by 36
Sensory motor remapping of space in human–machine interfaces
Mussa-Ivaldi, F. A., Casadio, M., Danziger, Z. C., Mosier, K. M., & Scheidt, R. A. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53752-2.00014-x · Cited by 35
Artemiadis, P., & Kyriakopoulos, K. J. (2009) · Springer tracts in advanced robotics · doi:10.1007/978-3-642-00196-3_29 · Cited by 35 · cited 2×
“Artemiadis et al use PCA to transform seven [174] and nine [12] channels to twodimensional synergy planes for simultaneous control of an anthropomorphic robot arm along a plane and in three dimensions respectively.”
BackgroundMethodSelf-citationForearm motion discrimination technique using real-time EMG signals
Mizuno, H., TSUJIUCHI, N., & KOIZUMI, T. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091100 · Cited by 34 · cited 1×
“Due to the non-Gaussian properties commonly associated with sEMG signals [148–150], higher order statistics [151–153] and information theory measures such as entropy [154] have also been proposed.”
BackgroundA comparison of proportional control methods for pattern recognition control
Simon, A. M., Stern, K., & Hargrove, L. J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090909 · Cited by 34 · cited 1×
“user-friendly than conventional on/off direct control [251].”
Ullah, K., & Kim, J. (2009) · International Conference on Autonomous Robots and Agents (ICARA) · doi:10.1109/icara.2000.4803995 · Cited by 34 · cited 1×
“Other nonlinear regression models typically only predict forces on a single DOF, using Hill-based muscle models [213, 214], other biomechanical models [215, 216], black-box approaches [217, 218], combinations of Hammerstein and Weiner models [219–222], or nonlinear polynomial models [220, 223].”
MethodA new hierarchical approach for simultaneous control of multi-joint powered prostheses
Young, A. J., Smith, L. H., Rouse, E. J., & Hargrove, L. J. (2012) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290709 · Cited by 33 · cited 2×
“[56, 134, 186], heirarchical LDA models [189],”
MethodTask-dependent impedance and implications for upper-limb prosthesis control
Blank, A. A., Okamura, A. M., & Whitcomb, L. L. (2014) · The International Journal of Robotics Research · doi:10.1177/0278364913517728 · Cited by 33
Pattern recognition with surface EMG signal based wavelet transformation
Şahin, U., & Sahin, F. (2012) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.2012.6377717 · Cited by 33 · cited 1×
“wavelet transform [24, 119] Time and frequency resolution”
A Real-time EMG-based Assistive Computer Interface for the Upper Limb Disabled
Choi, C., & Kim, J. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428465 · Cited by 32 · cited 1×
“Despite the lack of a global optimum solution, threat of overfitting to training data, slow training times, and general underperformance compared to SVMs [187], ANNs have proven to be effective for many myoelectric control schemes [24, 159, 203–207], with backpropagation networks proving robust in real-time control [2…”
BackgroundComparison of signal-to-noise ratio of myoelectric filters for prosthesis control
Meek, S. G., & Feterston, S. J. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.10.0009 · Cited by 32 · cited 1×
“constants [140] or Bayesian probabilities [141] at the expense”
BackgroundChapter 20 Multi-channel surface EMG in clinical neurophysiology
Stegeman, D. F., Zwarts, M. J., Anders, C., & Hashimoto, T. (2000) · Supplements to Clinical neurophysiology · doi:10.1016/s1567-424x(09)70151-5 · Cited by 31
A human forearm and wrist motion assist exoskeleton robot with EMG-based Fuzzy-neuro control
Gopura, R. A. R. C., & Kiguchi, K. (2008) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2008.4762793 · Cited by 31 · cited 1×
“Gopura et al [211] use a neuro-fuzzy approach to control a 3-DOF wrist exoskeleton.”
MethodA Novel Motion Estimate Method of Human Joint with EMG-Driven Model
Ding, Q., Zhao, X., Xiong, A., & Han, J. (2011) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2011.5780185 · Cited by 30 · cited 1×
“Other nonlinear regression models typically only predict forces on a single DOF, using Hill-based muscle models [213, 214], other biomechanical models [215, 216], black-box approaches [217, 218], combinations of Hammerstein and Weiner models [219–222], or nonlinear polynomial models [220, 223].”
MethodContinuous robot control using surface electromyography of atrophic muscles
Vogel, J., Bayer, J., & van der Smagt, P. (2013) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2013.6696449 · Cited by 29 · cited 5×
“[175], user choose muscle signals [15] Dual association, continuous”
BackgroundInfluentialTele-impedance control of a variable stiffness prosthetic hand
Hocaoğlu, E., & Patoğlu, V. (2012) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2012.6491192 · Cited by 28 · cited 1×
“applications in robot teleoperation [9–18] and other human–”
BackgroundInnervation zone of the vastus medialis muscle: position and effect on surface EMG variables
Gallina, A., Merletti, R., & Gazzoni, M. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/11/1411 · Cited by 27 · cited 1×
“When targeting specific muscles, ideal placement is close to the muscle belly away from innervation zones [99].”
BackgroundCamera control with EMG signals using Principal Component Analysis and support vector machines
Erkilinc, M. S., & Sahin, F. (2011) · IEEE International Systems Conference (SysCon) · doi:10.1109/syscon.2011.5929070 · Cited by 25 · cited 2×
“Other control schemes create abstract synergies from DWT [160] and spectral features [23] for more robust classifiers.”
BackgroundSpatio-spectral filters for low-density surface electromyographic signal classification
Huang, G., Zhang, Z., Zhang, D., & Zhu, X. (2013) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-1024-3 · Cited by 24 · cited 2×
“Huang et al [123] use spatio–spectral filtering to extract common spatio–spectral pattern features.”
Jesunathadas, M., Aidoor, S. S., Keenan, K. G., Farina, D., & Enoka, R. M. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.01.011 · Cited by 23 · cited 2×
“2) [61, 96].”
A Review of EMG recording technique
Ahmad, I., Ansari, F., & Dhanbad, S. (2012) · Cited by 23
A study for control of a power assist device
Kawai, S., Naruse, K., Yokoi, H., & Kakazu, Y. (2005) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2004.1389749 · Cited by 23 · cited 1×
“Despite the lack of a global optimum solution, threat of overfitting to training data, slow training times, and general underperformance compared to SVMs [187], ANNs have proven to be effective for many myoelectric control schemes [24, 159, 203–207], with backpropagation networks proving robust in real-time control [2…”
BackgroundOn the relationship between features extracted from EMG and force for constant and dynamic protocols
Andrade, A. D. O., & Andrade, C. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346693 · Cited by 22 · cited 2×
“Although good separators for isometric contractions, they are less reliable in dynamic environments and their computational complexity currently restricts any real-time applications [111].”
BackgroundLearning efficient control of robots using myoelectric interfaces
Ison, M. R., Antuvan, C. W., & Artemiadis, P. (2014) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2014.6907273 · Cited by 20 · cited 2×
“Ison et al [47] introduce a similar, but visually different”
BackgroundSelf-citationA lower limb EMG-driven biomechanical model for applications in rehabilitation robotics
Sartori, M., Reggiani, M., Mezzato, C., & Pagello, E. (2009) · Padua Research Archive (University of Padova) · Cited by 18
Tremor frequency based filter to extract voluntary movement of patients with essential tremor
Matsumoto, Y., Seki, M., Ando, T., Kobayashi, Y., Iijima, H., Nagaoka, M., & Fujie, M. G. (2012) · 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290905 · Cited by 16 · cited 1×
“Despite the lack of a global optimum solution, threat of overfitting to training data, slow training times, and general underperformance compared to SVMs [187], ANNs have proven to be effective for many myoelectric control schemes [24, 159, 203–207], with backpropagation networks proving robust in real-time control [2…”
BackgroundReduction of the effect of arm position variation on real-time performance of motion classification
Geng, Y., Zhang, F., Yang, L., Zhang, Y., & Li, G. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346539 · Cited by 16 · cited 1×
“Fougner et al [233] and Geng et al [234] propose sensor fusion as one solution, adding accelerometers and mechanomyogram signals respectively, to make classifiers more robust to posture changes, but the accuracy is still reliant on a representative dataset.”
BackgroundBoschmann, A., Platzner, M., Robrecht, M., Hahn, M. E., & Winkler, M. (2011) · DukeSpace (Duke University) · Cited by 14
Wurth, S. M., & Hargrove, L. J. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610329 · Cited by 14 · cited 1×
“Other works use Fittʼs law tests to objectify real-time performance [134, 199, 273].”
BackgroundRECOGNITION OF PALM FINGER MOVEMENTS ON THE BASIS OF EMG SIGNALS WITH THE APPLICATION OF WAVELETS
Krysztoforski, K., Wołczowski, A. R., Będziński, R., & Helt, K. (2004) · DOAJ (DOAJ: Directory of Open Access Journals) · Cited by 14
Classification of Surface EMG Signal Based on Energy Spectra Change
Hu, X. G., Yu, P., Yu, Q., Liu, W., & Qin, J. G. (2008) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2008.24 · Cited by 12 · cited 1×
“Frequency domain features provide information about the rate and shape of MUAPs [11, 107, 113–115, 155–157].”
BackgroundA computerized system for SEMG signals analysis and classifieation
Eldaydamony, E., El-Gayar, M., & Abou-Chadi, F. E.-Z. (2008) · National Radio Science Conference · doi:10.1109/nrsc.2008.4542388 · Cited by 12 · cited 1×
“feature extraction [253] and classification [128, 254], they can”
BackgroundFeature Extraction of Surface EMG Signal Based on Wavelet Coefficient Entropy
Hu, X., Yu, Q., Liu, W., & Qin, J. G. (2008) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2008.768 · Cited by 10
Wurth, S. M., & Hargrove, L. J. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696068 · Cited by 8 · cited 1×
“More quantitative measures are proposed in other works, defining throughput, overshoot, average speed, and direction ratio as useful indicators of real-time performance [274, 275].”
BackgroundMulti-class surface EMG classification using support vector machines and wavelet transform
Liu, H., Huang, Y., & Liu, D. (2010) · World Congress on Intelligent Control and Automation · doi:10.1109/wcica.2010.5554144 · Cited by 8 · cited 2×
“Before synergies were widely recognized in myoelectric control, Englehart et al [102] compared the performance of PCA on different sEMG feature sets (Hudgins’ original time domain (HTD) [106], short time Fourier transform, discrete wavelet transform (DWT), and wavelet packet transform (WPT)) to discriminate between 2-…”
BackgroundSensing millimeter-scale dynamics in cortical surface potentials for neural prosthetics
Kellis, S., Greger, B. E., Hanrahan, S. J., House, P. A., & Brown, R. B. (2011) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2011.6127165 · Cited by 7 · cited 1×
“rage users to associate thoughts with controls [259–261].”
BackgroundRecognition of hand motions via surface EMG signal with rough entropy
Zhong, J., Shi, J., Cai, Y., & Zhang, Q. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091018 · Cited by 7 · cited 1×
“Due to the non-Gaussian properties commonly associated with sEMG signals [148–150], higher order statistics [151–153] and information theory measures such as entropy [154] have also been proposed.”
BackgroundElectromyogram signal analysis and movement recognition based on wavelet packet transform
Chen, L., Peng, Y., Zu, L., & Xu, X. (2009) · IEEE International Conference on Information and Automation (ICIA) · doi:10.1109/icinfa.2009.5205151 · Cited by 7 · cited 2×
“frequency Wavelet packet transform [116–118], discrete”
BackgroundOptimal mapping of torus self-organizing map for forearm motion discrimination based on EMG
Kiso, A., & Seki, H. (2010) · Society of Instrument and Control Engineers of Japan · Cited by 4
Cited by
Santello, M., Bianchi, M., Gabiccini, M., Ricciardi, E., Salvietti, G., Prattichizzo, D., Ernst, M., Moscatelli, A., Jörntell, H., Kappers, A. M. L., et al. (2016) · Physics of Life Reviews · doi:10.1016/j.plrev.2016.02.001 · Cited by 307
A review of signals used in sleep analysis
Roebuck, A., Monasterio, V, Gederi, E., Osipov, M., Behar, J., Malhotra, A., Penzel, T., & Clifford, G. D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/1/r1 · Cited by 223
Microvascular imaging: techniques and opportunities for clinical physiological measurements
Allen, J., & Howell, K. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/7/r91 · Cited by 208
Hobbs, B., & Artemiadis, P. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00019 · Cited by 178
“Current advances in EMG and EEG analysis have led to broad applications of this control approach in rehabilitation robotics, however these challenges still require solving for thesemethods to become viable parts of rehabilitation, especially in exoskeleton and orthosis implementations (Ison and Artemiadis, 2014).”
BackgroundSelf-citationResnik, L., Huang, H. (., Winslow, A., Crouch, D. L., Zhang, F., & Wolk, N. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0361-3 · Cited by 174
“Nevertheless, almost all commercial electric prostheses, including modern dexterous hands, still use a ‘direct myoelectric control’ approach, first offered commercially in the 1970s [13].”
Background
Metadata
- Authors
- Ison, M., & Artemiadis, P.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-09-04
- Volume
- 11
- Issue
- 5
- Pages
- 051001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1984002649
- Cited by
- 225
- References
- 262
- FWCI
- 12.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.