The role of muscle synergies in myoelectric control: trends and challenges for simultaneous multifunction control
Open accessThe DOI matches its Crossref record; 262 of the 262 references it cites were found in a registry or an index.
Abstract
Myoelectric control is filled with potential to significantly change human-robot interaction due to the ability to non-invasively measure human motion intent. However, current control schemes have struggled to achieve the robust performance that is necessary for use in commercial applications. As demands in myoelectric control trend toward simultaneous multifunctional control, multi-muscle coordinations, or synergies, play larger roles in the success of the control scheme. Detecting and refining patterns in muscle activations robust to the high variance and transient changes associated with surface electromyography is essential for efficient, user-friendly control. This article reviews the role of muscle synergies in myoelectric control schemes by dissecting each component of the scheme with respect to associated challenges for achieving robust simultaneous control of myoelectric interfaces. Electromyography recording details, signal feature extraction, pattern recognition and motor learning based control schemes are considered, and future directions are proposed as steps toward fulfilling the potential of myoelectric control in clinically and commercially viable applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The pascal visual object classes (VOC) challenge
Everingham, M., Van Gool, L., Williams, C. K. I., Winn, J., & Zisserman, A. (2010) · International Journal of Computer Vision · doi:10.1007/s11263-009-0275-4 · Cited by 19,599
System Identification: Theory for the User
Lennart Ljung, A. (1987) · Cited by 17,690
System identification—Theory for the user
Sinha, N. K. (1989) · Automatica · doi:10.1016/0005-1098(89)90019-8 · Cited by 9,184
Advances in Neural Information Processing Systems 14: Proceedings of the 2001 Conference
(2002) · The MIT Press eBooks · doi:10.7551/mitpress/1120.001.0001 · Cited by 8,890
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
ALGORITHMS FOR NON-NEGATIVE MATRIX FACTORIZATION
Seung, D., & Lee, L.-W. (2001) · Cited by 4,753
Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control.
Zajac, F. E. (1989) · PubMed · Cited by 3,673
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 5×
“The features outperformed HTD, spectral, and spatial analysis methods in offline analysis.”
BackgroundMethodInfluentialTechniques of EMG signal analysis: detection, processing, classification and applications
Reaz, M. B. I., Hussain, M. S., & Mohd-Yasin, F. (2006) · Biological Procedures Online · doi:10.1251/bpo115 · Cited by 1,629 · cited 1×
“Each domain has been extensively described in previous works [3, 125, 126].”
BackgroundMyoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Cited by
Santello, M., Bianchi, M., Gabiccini, M., Ricciardi, E., Salvietti, G., Prattichizzo, D., Ernst, M., Moscatelli, A., Jörntell, H., Kappers, A. M. L., et al. (2016) · Physics of Life Reviews · doi:10.1016/j.plrev.2016.02.001 · Cited by 307
A review of signals used in sleep analysis
Roebuck, A., Monasterio, V, Gederi, E., Osipov, M., Behar, J., Malhotra, A., Penzel, T., & Clifford, G. D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/1/r1 · Cited by 223
Microvascular imaging: techniques and opportunities for clinical physiological measurements
Allen, J., & Howell, K. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/7/r91 · Cited by 208
Hobbs, B., & Artemiadis, P. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00019 · Cited by 178
“Current advances in EMG and EEG analysis have led to broad applications of this control approach in rehabilitation robotics, however these challenges still require solving for thesemethods to become viable parts of rehabilitation, especially in exoskeleton and orthosis implementations (Ison and Artemiadis, 2014).”
BackgroundSelf-citationResnik, L., Huang, H. (., Winslow, A., Crouch, D. L., Zhang, F., & Wolk, N. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0361-3 · Cited by 174
“Nevertheless, almost all commercial electric prostheses, including modern dexterous hands, still use a ‘direct myoelectric control’ approach, first offered commercially in the 1970s [13].”
BackgroundFilipiak, W., Filipiak, A., Sponring, A., Schmid, T., Zelger, B., Ager, C., Klodzinska, E., Denz, H., Pizzini, A., Lucciarini, P., et al. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/2/027111 · Cited by 173
A structured overview of trends and technologies used in dynamic hand orthoses
Bos, R. A., Haarman, C. J. W., Stortelder, T., Nizamis, K., Herder, J. L., Stienen, A. H. A., & Plettenburg, D. H. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0168-z · Cited by 162
“Command signal Detecting the user’s intention to serve as a command signal for the device is one of the larger challenges, because the control of the device is expected to be both intuitive and robust [35].”
BackgroundMotion capture sensing techniques used in human upper limb motion: a review
Yahya, M., Shah, J. A., Kadir, K. A., Yusof, Z. M., Khan, S., & Warsi, A. (2019) · Sensor Review · doi:10.1108/sr-10-2018-0270 · Cited by 82
Fascicular topography of the human median nerve for neuroprosthetic surgery
Delgado-Martínez, I., Badia, J., Pascual-Font, A., Rodríguez-Baeza, A., & Navarro, X. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00286 · Cited by 77
“Noticeably, the nerve fibers of the muscles that generate control signals for myoelectric prostheses (Ison and Artemiadis, 2014) exit the main trunk precisely at this level.”
BackgroundFani, S., Bianchi, M., Jain, S., Pimenta Neto, J. S., Boege, S., Grioli, G., Bicchi, A., & Santello, M. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00011 · Cited by 31
Metadata
- Authors
- Ison, M., & Artemiadis, P.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-09-04
- Volume
- 11
- Issue
- 5
- Pages
- 051001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1984002649
- Cited by
- 225
- References
- 262
- FWCI
- 12.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.