OBJECTIVE: Brain-computer interfaces (BCI) based on event-related potentials (ERP) were proven to be a reliable synchronous communication method. For everyday life situations, however, this synchronous mode is impractical because the system will deliver a selection even if the user is not paying attention to the stimulation. So far, research into attention-aware visual ERP-BCIs (i.e., asynchronous ERP-BCIs) has led to variable success. In this study, we investigate new approaches for detection of user engagement. APPROACH: Classifier output and frequency-domain features of electroencephalogram signals as well as the hybridization of them were used to detect the user's state. We tested their capabilities for state detection in different control scenarios on offline data from 21 healthy volunteers. MAIN RESULTS: The hybridization of classifier output and frequency-domain features outperformed the results of the single methods, and allowed building an asynchronous P300-based BCI with an average correct state detection accuracy of more than 95%. SIGNIFICANCE: Our results show that all introduced approaches for state detection in an asynchronous P300-based BCI can effectively avoid involuntary selections, and that the hybrid method is the most effective approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
Single-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138
An efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859
A P300-based brain–computer interface for people with amyotrophic lateral sclerosis
Nijboer, F., Sellers, E. W., Mellinger, J., Jordan, M. A., Matuz, T., Furdea, A., Halder, S., Mochty, U., Krusienski, D. J., Vaughan, T. M., et al. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.03.034 · Cited by 633 · cited 1×
“This method, an extension of Fisher ʼ s linear discriminant analysis, is an established classi fi cation method for visual P300 BCIs [8, 9, 12].”
MethodSelf-citationTownsend, G., LaPallo, B. K., Boulay, C. B., Krusienski, D. J., Frye, G. E., Hauser, C. K., Schwartz, N. E., Vaughan, T. M., Wolpaw, J. R., & Sellers, E. W. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.030 · Cited by 570 · cited 1×
“…since 1988 concerning: the data acquisition (e.g., dry electrodes [10, 11]), the signal processing (e.g., different classi fi cation methods [12, 13]), and the paradigm presentation (e.g., checkerboard fl ashing pattern [14], binomial fl ashing pattern [15], and famous faces highlighting [16]).”
BackgroundAutocalibration and recurrent adaptation: Towards a plug and play online ERD-BCI
Faller, J., Vidaurre, C., Solis-Escalante, T., Neuper, C., & Scherer, R. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2189584 · Cited by 180 · cited 1×
“These elements were selected with a sensorimotor rhythm (SMR)-based BCI [23, 24].”
MethodSelf-citation
Cited by
Discriminative Canonical Pattern Matching for Single-Trial Classification of ERP Components
Xiao, X., Xu, M., Jin, J., Wang, Y., Jung, T.-P., & Ming, D. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2958641 · Cited by 113
Performance Enhancement of P300 Detection by Multiscale-CNN
Wang, H., Pei, Z., Xu, L., Xu, T., Bezerianos, A., Sun, Y., & Li, J. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3067943 · Cited by 35
“In particular, P300 [5], a decision-making-related positive waveform occurring approximately 300 ms after the onset of an external stimulus (visual, auditory, or tactile stimulus), has been repeatedly adopted in the ERP-based BCI system [6].”
MethodAn improved EEGNet for single-trial EEG classification in rapid serial visual presentation task
Zhang, H., Wang, Z., Yu, Y., Yin, H., Chen, C., & Wang, H. (2022) · Brain Science Advances · doi:10.26599/bsa.2022.9050007 · Cited by 30
“Event-related potential (ERP)-based non-invasive BCI has been widely used in different EEG signals [5].”
Background
Metadata
- Authors
- Pinegger, A., Faller, J., Halder, S., Wriessnegger, S. C., & Müller-Putz, G. R.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2015-01-14
- Volume
- 12
- Issue
- 1
- Pages
- 014001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2016056969
- Cited by
- 55
- References
- 6
- FWCI
- 3.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Control or non-control state: that is the question! An asynchronous visual P300-based BCI approach. https://app.cochat.ai/papers/10.1088/1741-2560/12/1/014001
- The paper
- Pinegger, A., Faller, J., Halder, S., Wriessnegger, S. C., & Müller-Putz, G. R. (2015). Control or non-control state: that is the question! An asynchronous visual P300-based BCI approach. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/12/1/014001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.