Sensor fusion and computer vision for context-aware control of a multi degree-of-freedom prosthesis
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Myoelectric activity volitionally generated by the user is often used for controlling hand prostheses in order to replicate the synergistic actions of muscles in healthy humans during grasping. Muscle synergies in healthy humans are based on the integration of visual perception, heuristics and proprioception. Here, we demonstrate how sensor fusion that combines artificial vision and proprioceptive information with the high-level processing characteristics of biological systems can be effectively used in transradial prosthesis control. APPROACH: We developed a novel context- and user-aware prosthesis (CASP) controller integrating computer vision and inertial sensing with myoelectric activity in order to achieve semi-autonomous and reactive control of a prosthetic hand. The presented method semi-automatically provides simultaneous and proportional control of multiple degrees-of-freedom (DOFs), thus decreasing overall physical effort while retaining full user control. The system was compared against the major commercial state-of-the art myoelectric control system in ten able-bodied and one amputee subject. All subjects used transradial prosthesis with an active wrist to grasp objects typically associated with activities of daily living. MAIN RESULTS: The CASP significantly outperformed the myoelectric interface when controlling all of the prosthesis DOF. However, when tested with less complex prosthetic system (smaller number of DOF), the CASP was slower but resulted with reaching motions that contained less compensatory movements. Another important finding is that the CASP system required minimal user adaptation and training. SIGNIFICANCE: The CASP constitutes a substantial improvement for the control of multi-DOF prostheses. The application of the CASP will have a significant impact when translated to real-life scenarious, particularly with respect to improving the usability and acceptance of highly complex systems (e.g., full prosthetic arms) by amputees.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of NASA-TLX (Task Load Index): Results of Empirical and Theoretical Research
(1988) · Advances in Psychology · doi:10.1016/s0166-4115(08)62386-9 · Cited by 15,003
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
Light, C. M., Chappell, P. H., & Kyberd, P. J. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.32737 · Cited by 417
A survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252 · cited 1×
“Sensor fusion using electrophysiological signals as well as pressure sensors and inertial units was applied to improve intention detection in the classic patternrecognition- and regression-based manual control systems [40].”
MethodGonzalez, J., Soma, H., Sekine, M., & Yu, W. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-33 · Cited by 87
Cited by
Artificial intelligence meets medical robotics
Yip, M., Salcudean, S., Goldberg, K., Althoefer, K., Menciassi, A., Opfermann, J. D., Krieger, A., Swaminathan, K., Walsh, C. J., Huang, H. (., et al. (2023) · Science · doi:10.1126/science.adj3312 · Cited by 207
An Artificial Somatic Reflex Arc
He, K., Liu, Y., Wang, M., Chen, G., Jiang, Y., Yu, J., Wan, C., Qi, D., Xiao, M., Leow, W. R., et al. (2020) · Advanced Materials · doi:10.1002/adma.201905399 · Cited by 173
Shi, C., Yang, D., Zhao, J., & Liu, H. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3007625 · Cited by 87
“For example, in [14], the depth information has been introduced into the control of the prosthetic hand.”
BackgroundInfluentialChallenges in Task Incremental Learning for Assistive Robotics
Feng, F., Chan, R. H. M., Shi, X., Zhang, Y., & She, Q. (2020) · IEEE Access · doi:10.1109/access.2019.2955480 · Cited by 39
Metadata
- Authors
- Markovic, M., Dosen, S., Popovic, D., Graimann, B., & Farina, D.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2015-11-03
- Volume
- 12
- Issue
- 6
- Pages
- 066022
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2223144325
- Cited by
- 137
- References
- 6
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensor fusion and computer vision for context-aware control of a multi degree-of-freedom prosthesis. https://app.cochat.ai/papers/10.1088/1741-2560/12/6/066022
- The paper
- Markovic, M., Dosen, S., Popovic, D., Graimann, B., & Farina, D. (2015). Sensor fusion and computer vision for context-aware control of a multi degree-of-freedom prosthesis. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/12/6/066022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.