Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Open accessAbstract
The recent introduction of novel multifunction hands as well as new control paradigms increase the demand for advanced prosthetic control systems. In this context, an unambiguous terminology and a good understanding of the nature of the control problem is important for efficient research and communication concerning the subject. Thus, one purpose of this paper is to suggest an unambiguous taxonomy, applicable to control systems for upper limb prostheses and also to prostheses in general. A functionally partitioned model of the prosthesis control problem is also presented along with the taxonomy. In the second half of the paper, the suggested taxonomy has been exploited in a comprehensive literature review on proportional myoelectric control of upper limb prostheses. The review revealed that the methods for system training have not matured at the same pace as the novel multifunction prostheses and more advanced intent interpretation methods. Few publications exist regarding the choice of training method and the composition of the training data set. In this context, the notion of outcome measures is essential. By definition, system training involves optimization, and the quality of the results depends heavily on the choice of appropriate optimization criteria. In order to further promote the development of proportional myoelectric control, these topics need to be addressed.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Sophisticated approaches have been developed to control prosthetic hands intuitively.
“Major strides have been made in the development of approaches to control these hands either by decoding motor intent from myoelectric signals (Fougner et al., 2012;Schultz and Kuiken, 2011) or from the activation of neurons in motor cortex (Bensmaia and Miller, 2014;Wodlinger et al., 2015).”
From Biomimetic approaches to bionic touch through a peripheral nerve interface (2015) · cites this paper as Fougner et al., 2012
Cites
Pattern Recognition and Neural Networks
Ripley, B. D. (1996) · Cambridge University Press eBooks · doi:10.1017/cbo9780511812651 · Cited by 6,446 · see citing works
Impedance Control: An Approach to Manipulation: Part I—Theory
Hogan, N. (1985) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3140702 · Cited by 3,673 · see citing works
Impedance Control: An Approach to Manipulation
Hogan, N. (1984) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.1984.4788393 · Cited by 2,964 · see citing works
Estimating the Prevalence of Limb Loss in the United States: 2005 to 2050
Ziegler‐Graham, K., MacKenzie, E. J., Ephraim, P. L., Travison, T. G., & Brookmeyer, R. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.11.005 · Cited by 2,823 · see citing works
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · see citing works
Self-citationA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743 · see citing works
The Variational Principles of Mechanics
Lanczos, C. (1949) · University of Toronto Press eBooks · doi:10.3138/9781487583057 · Cited by 1,355 · see citing works
Upper limb prosthesis use and abandonment
Biddiss, E. A., & Chau, T. T. (2007) · Prosthetics and Orthotics International · doi:10.1080/03093640600994581 · Cited by 1,123 · see citing works
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089 · see citing works
Adaptive control of mechanical impedance by coactivation of antagonist muscles
Hogan, N. (1984) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1984.1103644 · Cited by 1,064 · see citing works
Myoelectric signal processing for control of powered limb prostheses
Parker, P. K., Englehart, K. B., & Hudgins, B. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.08.006 · Cited by 648 · see citing works
Self-citationClassification of the myoelectric signal using time-frequency based representations
Englehart, K. B., Hudgins, B., Parker, P. A., & Stevenson, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00066-1 · Cited by 641 · see citing works
Self-citationJiang, N., Englehart, K. B., & Parker, P. A. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 453 · see citing works
Self-citationResolving the Limb Position Effect in Myoelectric Pattern Recognition
Fougner, A. L., Scheme, E., Chan, A. D. C., Englehart, K. B., & Stavdahl, Ø. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163529 · Cited by 403 · see citing works
Self-citationMuceli, S., & Farina, D. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2178039 · Cited by 285 · see citing works
Kuiken, T., Marasco, P. D., Lock, B. A., Harden, R. N., & Dewald, J. P. A. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706525104 · Cited by 284 · see citing works
Implantable Myoelectric Sensors (IMESs) for Intramuscular Electromyogram Recording
Weir, R. F. F., Troyk, P. R., DeMichele, G. A., Kerns, D., Schorsch, J. F., & Maas, H. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005942 · Cited by 264 · see citing works
Nielsen, J. L. G., Holmgaard, S., Jiang, N., Englehart, K. B., Farina, D., & Parker, P. A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2068298 · Cited by 258 · see citing works
Self-citationHogan, N., & Mann, R. W. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326652 · Cited by 244 · see citing works
Development of the Utah Artificial Arm
Jacobson, S. C., Knutti, D. F., Johnson, R. T., & Sears, H. H. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.325033 · Cited by 235 · see citing works
Prediction of handgrip forces using surface EMG of forearm muscles
Hoozemans, M. J. M., & van Dieën, J. H. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.09.001 · Cited by 212 · see citing works
Myoelectric control of prostheses.
Parker, P. A., & Scott, R. N. (1986) · PubMed · Cited by 199 · see citing works
Self-citationAu, A. T. C., & Kirsch, R. F. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895950 · Cited by 182 · see citing works
Myoelectric Prostheses: state of the art
Scott, R. N., & Parker, P. A. (1988) · Journal of Medical Engineering & Technology · doi:10.3109/03091908809030173 · Cited by 171 · see citing works
Self-citationSelective Classification for Improved Robustness of Myoelectric Control Under Nonideal Conditions
Scheme, E., Englehart, K. B., & Hudgins, B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2113182 · Cited by 169 · see citing works
Comparison of control strategies for an EMG controlled orthotic exoskeleton for the hand
DiCicco, M., Lucas, L., & Matsuoka, Y. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2004.1308056 · Cited by 165 · see citing works
Closed-loop control in prosthetic systems: Historical perspective
Childress, D. S. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363433 · Cited by 158 · see citing works
Multi-subject/daily-life activity EMG-based control of mechanical hands
Castellini, C., Fiorilla, A. E., & Sandini, G. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-41 · Cited by 155 · see citing works
Dynamic muscle force predictions from EMG: an artificial neural network approach
Liu, M. M., Herzog, W., & Savelberg, H. H. C. M. (1999) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(99)00014-0 · Cited by 151 · see citing works
Hargrove, L. J., Losier, Y. G., Lock, B. A., Englehart, K. B., & Hudgins, B. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353424 · Cited by 151 · see citing works
Self-citationSignal processing for the multistate myoelectric channel
Parker, P. A., Stuller, J. A., & Scott, R. N. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10545 · Cited by 130 · see citing works
Self-citationTHE USE OF MYO-ELECTRIC CURRENTS IN THE OPERATION OF PROSTHESES
Battye, C. K., Nightingale, A., & Whillis, J. (1955) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.37b3.506 · Cited by 130 · see citing works
Hogan, N., & Mann, R. W. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326653 · Cited by 126 · see citing works
MARCUS: a two degree of freedom hand prosthesis with hierarchical grip control
Kyberd, P., Holland, O. E., Chappell, P. H., Smith, S., Tregidgo, R., Bagwell, P. J., & Snaith, M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.372895 · Cited by 121 · see citing works
Self-citationThe Southampton Hand: an intelligent myoelectric prosthesis.
Kyberd, P., & Chappell, P. H. (1994) · PubMed · Cited by 119 · see citing works
Self-citationSimon, A. M., Hargrove, L. J., Lock, B. A., & Kuiken, T. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2155063 · Cited by 119 · see citing works
Development of an Implantable Myoelectric Sensor for Advanced Prosthesis Control
Merrill, D. R., Lockhart, J., Troyk, P. R., Weir, R. F., & Hankin, D. L. (2011) · Artificial Organs · doi:10.1111/j.1525-1594.2011.01219.x · Cited by 117 · see citing works
A Method for the Control of Multigrasp Myoelectric Prosthetic Hands
Dalley, S. A., Varol, H. A., & Goldfarb, M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2175488 · Cited by 113 · see citing works
Sensory capacity of reinnervated skin after redirection of amputated upper limb nerves to the chest
Marasco, P. D., Schultz, A. E., & Kuiken, T. A. (2009) · Brain · doi:10.1093/brain/awp082 · Cited by 113 · see citing works
REAL-TIME MYOELECTRIC CONTROL IN A VIRTUAL ENVIRONMENT TO RELATE USABILITY VS. ACCURACY
Lock, B. A., Englehart, K. B., & Hudgins, B. (2005) · DukeSpace (Duke University) · Cited by 102 · see citing works
Survey of upper limb prosthesis users in Sweden, the United Kingdom and Canada
Kyberd, P., & Hill, W. (2011) · Prosthetics and Orthotics International · doi:10.1177/0309364611409099 · Cited by 98 · see citing works
Self-citationPROPORTIONAL MYOELECTRIC HAND CONTROL: AN EVALUATION
Sears, H. H., & Shaperman, J. (1991) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-199102000-00005 · Cited by 95 · see citing works
Electromyogram-based neural network control of transhumeral prostheses
Pulliam, C. L., Lambrecht, J. M., & Kirsch, R. F. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.12.0237 · Cited by 94 · see citing works
Sensory-feedback system compatible with myoelectric control
Scott, R. N., Brittain, R. H., Caldwell, R. R., Cameron, A. B., & Dunfield, V. A. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442481 · Cited by 93 · see citing works
Model adaptation with least-squares SVM for adaptive hand prosthetics
Orabona, F., Castellini, C., Barbara Caputo, B., Fiorilla, A. E., & Sandini, G. (2009) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2009.5152247 · Cited by 89 · see citing works
Cheron, G. A., Draye, J.-P., Bourgeios, M., & Libert, G. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.488803 · Cited by 86 · see citing works
MYO-ELECTRIC CONTROL OF POWERED PROSTHESES
Bottomley, A. H. (1965) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.47b3.411 · Cited by 86 · see citing works
Rehabilitation in limb deficiency. 4. Limb amputation
Esquenazi, A., & Meier, R. H. (1996) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(96)90239-7 · Cited by 78 · see citing works
The Control of Upper‐Extremity Prostheses and Orthoses
MAXWELL, C. M. (1975) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.1975.tb95195.x · Cited by 77 · see citing works
A review of the methods of processing EMG for use as a proportional control signal.
Hogan, N. (1976) · PubMed · Cited by 74 · see citing works
Practical Methods for Controlling Powered Upper-Extremity Prostheses
Williams, T. W. (1990) · Assistive Technology · doi:10.1080/10400435.1990.10132142 · Cited by 71 · see citing works
Almstr�m, C., Herberts, P., & K�rner, L. (1981) · International Orthopaedics · doi:10.1007/bf00286094 · Cited by 66 · see citing works
Cineplasty as a control input for externally powered prosthetic components.
(2002) · Cited by 65 · see citing works
Ziai, A., & Menon, C. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-56 · Cited by 57 · see citing works
Sebelius, F., Eriksson, L., Balkenius, C., & Laurell, T. (2006) · Journal of Medical Engineering & Technology · doi:10.1080/03091900512331332546 · Cited by 56 · see citing works
Comparison of electromyography and force as interfaces for prosthetic control
Corbett, E. A., Perreault, E. J., & Kuiken, T. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.03.0028 · Cited by 55 · see citing works
Dimensional change in muscle as a control signal for powered upper limb prostheses: a pilot study
Kenney, L. P. J., Lisitsa, I., Bowker, P., et al. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00089-2 · Cited by 54 · see citing works
Simultaneous, Proportional, Multi-axis Prosthesis Control using Multichannel Surface EMG
Yatsenko, D., McDonnall, D., & Guillory, K. S. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353749 · Cited by 54 · see citing works
Hill, W., Stavdahl, Ø., Hermansson, L. N., Kyberd, P., Swanson, S., & Hubbard, S. (2009) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0b013e3181a1d2dc · Cited by 53 · see citing works
Self-citationEnhanced EMG signal processing for simultaneous and proportional myoelectric control
Nielsen, J. L. G., Holmgaard, S., Jiang, N., Englehart, K. B., Farina, D., & Parker, P. K. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5332745 · Cited by 50 · see citing works
Self-citationA Novel Concept for a Prosthetic Hand With a Bidirectional Interface: A Feasibility Study
Cipriani, C., Antfolk, C., Balkenius, C., Rosén, B., Lundborg, G., Carrozza, M. C., & Sebelius, F. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2031242 · Cited by 48 · see citing works
Feedback in Myoelectric Prostheses
Scott, R. N. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199007000-00010 · Cited by 46 · see citing works
Cybernetic limb prosthesis: The ALZA distinguished lecture
Mann, R. W. (1981) · Annals of Biomedical Engineering · doi:10.1007/bf02584556 · Cited by 46 · see citing works
Laboratory Evaluation of a Unified Theory for Simultaneous Multiple Axis Artificial Arm Control
Jerard, R. B., & Jacobsen, S. C. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3149574 · Cited by 46 · see citing works
Microprocessor control of an artificial arm
Nightingale, J. M. (1985) · Journal of Microcomputer Applications · doi:10.1016/0745-7138(85)90015-6 · Cited by 46 · see citing works
Problems of bioelectric control
Kobrinskii, A. E., Bolkhovitin, S. V., Voskoboinikova, L. M., Ioffe, D. M., Polyan, E. P., Popov, B. P., Slavutskii, I. L., Sysin, A. J., & Yakobson, Y. S. (1960) · IFAC Proceedings Volumes · doi:10.1016/s1474-6670(17)70141-3 · Cited by 45 · see citing works
Signal Processing for Proportional Myoelectric Control
Evans, H. B., Pan, Z., Parker, P. A., et al. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325330 · Cited by 42 · see citing works
Self-citationA mechanical hand with automatic proportional control of prehension
Salisbury, L. L., & Colman, A. B. (1967) · Medical & Biological Engineering & Computing · doi:10.1007/bf02479145 · Cited by 40 · see citing works
Philipson, L., & Pg, L. (1988) · PubMed · Cited by 39 · see citing works
Keir, P. J., & Mogk, J. P. M. (2005) · Ergonomics · doi:10.1080/00140130500277591 · Cited by 38 · see citing works
Control of Powered Upper Limb Prostheses
Parker, P. A., Englehart, K. B., & Hudgins, B. (2004) · doi:10.1002/0471678384.ch18 · Cited by 36 · see citing works
Self-citationMMG-based multisensor data fusion for prosthesis control
Silva, J., Chau, T. T., & Goldenberg, A. A. (2004) · doi:10.1109/iembs.2003.1280527 · Cited by 33 · see citing works
A comparison of proportional control methods for pattern recognition control
Simon, A. M., Stern, K., & Hargrove, L. J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090909 · Cited by 33 · see citing works
Muscle substitutes and myo-electric control
Bottomley, A. H., Wilson, A. B. K., & Nightingale, A. (1963) · Radio and Electronic Engineer · doi:10.1049/ree.1963.0169 · Cited by 33 · see citing works
The design of a complete arm prosthesis.
Dc, S., & Kenworthy, G. (1973) · PubMed · Cited by 30 · see citing works
Prosthesis-Guided Training For Practical Use Of Pattern Recognition Control Of Prostheses
Lock, B. A., Simon, A. M., Stubblefield, K. A., & Hargrove, L. J. (2011) · DukeSpace (Duke University) · Cited by 29 · see citing works
The ToMPAW Modular Prosthesis: A Platform for Research in Upper-Limb Prosthetics
Kyberd, P., Poulton, A., Sandsj, L., et al. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0b013e31802d46f8 · Cited by 28 · see citing works
Self-citationREITER, R. (1948) · PubMed · Cited by 27 · see citing works
Proportional Myoelectric Control of a Multifunction Upper-limb Prosthesis
Fougner, A. L. (2007) · NORA - Norwegian Open Research Archives · Cited by 26 · see citing works
Self-citationPrediction of forearm muscle activity during gripping
Mogk, J. P. M., & Keir, P. J. (2006) · Ergonomics · doi:10.1080/00140130600777433 · Cited by 26 · see citing works
Control of a single degree of freedom artificial hand
Chappell, P. H., Nightingale, J. M., Kyberd, P., et al. (1987) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(87)90013-6 · Cited by 26 · see citing works
Self-citationMann, R. W. (1968) · Proceedings of the Institution of Mechanical Engineers Conference Proceedings · doi:10.1243/pime_conf_1968_183_183_02 · Cited by 24 · see citing works
BIOELECTRIC CONTROL OF PROSTHESES
Alter, R. (1966) · Cited by 21 · see citing works
An adaptive control system for a complete hand/arm prosthesis
Swain, I., & Nightingale, J. M. (1980) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(80)90142-9 · Cited by 20 · see citing works
Graupe, D., Aa, B., Wj, M., et al. (1977) · PubMed · Cited by 20 · see citing works
An externally powered controlled complete arm prosthesis
Simpson, D. C., & Smith, J. G. (1977) · Journal of Medical Engineering & Technology · doi:10.3109/03091907709162194 · Cited by 19 · see citing works
Myoelectric control of Powered Prostheses
Childress, D. S. (1982) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/emb-m.1982.5005841 · Cited by 19 · see citing works
Philipson, L. (1985) · Medical & Biological Engineering & Computing · doi:10.1007/bf02444020 · Cited by 15 · see citing works
Implantable myoelectric control system with sensory feedback
Lovely, D. F., Hudgins, B., & Scott, R. N. (1985) · Medical & Biological Engineering & Computing · doi:10.1007/bf02444035 · Cited by 15 · see citing works
Digital approaches to myoelectric state control of prostheses.
Philipson, L., Ds, C., & Strysik, J. S. (1981) · PubMed · Cited by 15 · see citing works
Signals and Signal Processing for Myoelectric Control
Lovely, D. F. (2004) · Springer eBooks · doi:10.1007/978-3-642-18812-1_3 · Cited by 13 · see citing works
Losier, Y. G., Englehart, K. B., & Hudgins, B. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353750 · Cited by 12 · see citing works
Self-citationPowered Upper Limb Prosthetics in Adults
Alley, R. D., & Sears, H. H. (2004) · Springer eBooks · doi:10.1007/978-3-642-18812-1_7 · Cited by 11 · see citing works
Control of Powered Prosthetic Hand Using Multidimensional Ultrasound Signals: A Pilot Study
Chen, X., Chen, S., & Guo, D. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-21657-2_34 · Cited by 11 · see citing works
Development of a multifunctional adaptive hand prosthesis.
Moore, D. (1980) · ePrints Soton (University of Southampton) · Cited by 11 · see citing works
Basic study on combined motion estimation using multichannel surface EMG signals
Nagata, K., & Magatani, K. (2011) · doi:10.1109/iembs.2011.6091938 · Cited by 10 · see citing works
Simon, A. M., Lock, B. A., Stubblefield, K. A., et al. (2011) · DukeSpace (Duke University) · Cited by 7 · see citing works
CANCELLATION OF FORCE INDUCED ARTIFACTS IN SURFACE EMG USING FSR MEASUREMENTS
Fougner, A. L., Sæther, M., Stavdahl, Ø., et al. (2008) · DukeSpace (Duke University) · Cited by 7 · see citing works
Self-citationCLINICALLY PRACTICAL APPLICATIONS OF PATTERN RECOGNITION FOR MYOELECTRIC PROSTHESES
Lock, B. A., Schultz, A. E., & Kuiken, T. (2008) · DukeSpace (Duke University) · Cited by 6 · see citing works
Implantable Myoelectric Sensors (IMES)
Weir, R. F., Troyk, P. R., DeMichele, G. A., Lowery, M. M., & Kuiken, T. (2005) · DukeSpace (Duke University) · Cited by 5 · see citing works
Design of a Myoelectric Signal Conditioner
Childress, D. S. (1969) · Journal of the Audio Engineering Society · Cited by 5 · see citing works
Ultrasound Based Estimation Of Muscle Contraction
Stavdahl, Ø., Grønningsaeter, A., & Malvig, K. E. (1997) · DukeSpace (Duke University) · Cited by 3 · see citing works
Self-citationMiguelez, J. M. (2002) · DukeSpace (Duke University) · Cited by 1 · see citing works
MULTIMODAL INPUT DEVICE WITH SEMG AND CONTACT FORCE SENSORS
Stavdahl, Ø., Kyberd, P., Magne, T., et al. (2011) · DukeSpace (Duke University) · Cited by 1 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Atzori, M., Cognolato, M., & Müller, H. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00009 · Cited by 684 · see citing works
Bi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418 · see citing works
A closed-loop hand prosthesis with simultaneous intraneural tactile and position feedback
D’Anna, E., Valle, G., Mazzoni, A., Strauss, I., Iberite, F., Patton, J., Petrini, F. M., Raspopovic, S., Granata, G., Di Iorio, R., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aau8892 · Cited by 321 · see citing works
Jiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278411 · Cited by 269 · see citing works
A survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252 · see citing works
Biomimetic approaches to bionic touch through a peripheral nerve interface
Saal, H. P., & Bensmaia, S. J. (2015) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2015.06.010 · Cited by 179 · see citing works
“Major strides have been made in the development of approaches to control these hands either by decoding motor intent from myoelectric signals (Fougner et al., 2012; Schultz and Kuiken, 2011) or from the activation of neurons in motor cortex (Bensmaia and Miller, 2014; Wodlinger et al., 2015).”
Control of prosthetic hands via the peripheral nervous system
Ciancio, A. L., Cordella, F., Barone, R., Romeo, R. A., Bellingegni, A. D., Sacchetti, R., Davalli, A., Di Pino, G., Ranieri, F., Di Lazzaro, V., et al. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00116 · Cited by 131 · see citing works
Interfaces with the Peripheral Nerve for the Control of Neuroprostheses
del Valle, J., & Navarro, X. (2013) · International Review of Neurobiology · doi:10.1016/b978-0-12-420045-6.00002-x · Cited by 105 · see citing works
Ahmadizadeh, C., Merhi, L.-K., Pousett, B., Sangha, S., & Menon, C. (2017) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2017.2747899 · Cited by 57 · see citing works
Multichannel electrotactile feedback for simultaneous and proportional myoelectric control
Patel, G. K., Dosen, S., Castellini, C., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056015 · Cited by 58 · see citing works
A bioelectric neural interface towards intuitive prosthetic control for amputees
Nguyen, A. T., Xu, J., Jiang, M., Luu, D. K., Wu, T., Tam, W.-K., Zhao, W., Drealan, M. W., Overstreet, C. K., Zhao, Q., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abc3d3 · Cited by 52 · see citing works
Learning-Based Motion-Intention Prediction for End-Point Control of Upper-Limb-Assistive Robots
Yang, S., Garg, N. P., Gao, R., Yuan, M., Noronha, B., Ang, W. T., & Accoto, D. (2023) · Sensors · doi:10.3390/s23062998 · Cited by 20 · see citing works
- Authors
- Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A.
- Affiliations
- Norwegian University of Science and Technology (NO)
- University of New Brunswick (CA)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2012-09
- Volume
- 20
- Issue
- 5
- Pages
- 663-677
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W1971702085
- Cited by
- 495
- References
- 104
- Citations by year
- 2026: 15 · 2025: 17 · 2024: 32 · 2023: 41 · 2022: 37 · 2021: 48 · 2020: 43 · 2019: 53 · 2018: 46 · 2017: 48 · 2016: 32 · 2015: 28 · 2014: 39 · 2013: 16
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- other-oa
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- BIBSYS Brage (BIBSYS (Norway)) (submittedVersion)
- NORA - Norwegian Open Research Archives (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- upper limb prosthesis, myoelectric control, outcome measures
- MeSH terms
- Artificial Limbs, Biofeedback, Psychology, Computer Simulation, Electromyography, Humans, Models, Biological, Movement Disorders, Terminology as Topic, Therapy, Computer-Assisted, Muscle, Skeletal, Upper Extremity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review