Analysis of the quasi-static approximation for calculating potentials generated by neural stimulation
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
In models of electrical stimulation of the nervous system, the electric potential is typically calculated using the quasi-static approximation. The quasi-static approximation allows Maxwell's equations to be simplified by ignoring capacitive, inductive and wave propagation contributions to the potential. While this simplification has been validated for bioelectric sources, its application to rapid stimulation pulses, which contain more high-frequency power, may not be appropriate. We compared the potentials calculated using the quasi-static approximation with those calculated from the exact solution to the inhomogeneous Helmholtz equation. The mean absolute errors between the two potential calculations were limited to 5-13% for pulse widths commonly used for neural stimulation (25 micros-1 ms). We also quantified the excitation properties of extracellular point source stimulation of a myelinated nerve fiber model using potentials calculated from each method. Deviations between the strength-duration curves for potentials calculated using the quasi-static (sigma = 0.105 S m(-1)) and Helmholtz approaches ranged from 3 to 16%, with the minimal error occurring for 100 micros pulses. Differences in the threshold-distance curves for the two calculations ranged from 0 to 9%, for the same value of quasi-static conductivity. A sensitivity analysis of the material parameters revealed that the potential was much more strongly dependent on the conductivity than on the permittivity. These results indicate that for commonly used stimulus pulse parameters, the exact solution for the potential can be approximated by quasi-static simplifications only for appropriate values of conductivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152
Advanced engineering electromagnetics
Balanis, C. A. (1989) · Cited by 7,011
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
The dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156
The NEURON Simulation Environment
Hines, M. L., & Carnevale, N. T. (1997) · Neural Computation · doi:10.1162/neco.1997.9.6.1179 · Cited by 2,658
Physical properties of tissue : a comprehensive reference book
Duck, F. A. (1990) · Cited by 1,675
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
Dielectric properties of tissues and biological materials: a critical review.
Foster, K. R., & Schwan, H. P. (1989) · PubMed · Cited by 1,503
Pethig, R., & Kell, D. B. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/8/001 · Cited by 796
Considerations of quasi-stationarity in electrophysiological systems
Plonsey, R., & Heppner, D. B. (1967) · The Bulletin of Mathematical Biophysics · doi:10.1007/bf02476917 · Cited by 619
Tissue and electrode capacitance reduce neural activation volumes during deep brain stimulation
Butson, C. R., & McIntyre, C. C. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.06.023 · Cited by 335
Bédard, C., Kröger, H., & Destexhe, A. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74250-2 · Cited by 264 · cited 1×
“Bedard et al (2004) modeled this filtering effect in EEGs and local field potentials using spatial profiles for the extracellular conductivity and permittivity.”
MethodSelective Microstimulation of Central Nervous System Neurons
McIntyre, C. C., & Grill, W. M. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.262 · Cited by 258
Self-citationBédard, C., Kröger, H., Alain Destexhe, A., & Alain Destexhe, A. (2004) · Cited by 249
Finite Element Analysis of the Current-Density and Electric Field Generated by Metal Microelectrodes
McIntyre, C. C., & Grill, W. M. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1352640 · Cited by 161
Self-citationThe volume conductor may act as a temporal filter on the ECG and EEG
Stinstra, J. G., & Peters, M. J. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02518873 · Cited by 91
Plonsey, R., & Barr, R. C. (2000) · Springer eBooks · doi:10.1007/978-1-4757-3152-1 · Cited by 86
Cited by
Edwards, D., Cortes, M., Datta, A., Minhas, P., Wassermann, E. M., & Bikson, M. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.01.042 · Cited by 468
A Computational Model for Epidural Electrical Stimulation of Spinal Sensorimotor Circuits
Capogrosso, M., Wenger, N., Raspopovic, S., Musienko, P., Beauparlant, J., Bassi Luciani, L., Courtine, G., & Micera, S. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.1688-13.2013 · Cited by 435
“To simulate different amplitudes, we multiplied the voltage solutions with a proper scalar factor, which is appropriate under quasi-static assumptions (Bossetti et al., 2008).”
MethodAberra, A. S., Wang, B., Grill, W. M., & Peterchev, A. V. (2020) · Brain Stimulation · doi:10.1016/j.brs.2019.10.002 · Cited by 323
Self-citationDeng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/016007 · Cited by 216
Electroconvulsive Therapy Stimulus Parameters: Rethinking Dosage
Peterchev, A. V., Rosa, M. A., Deng, Z.-D., Prudic, J., & Lisanby, S. H. (2010) · The Journal of ECT · doi:10.1097/yct.0b013e3181e48165 · Cited by 213
Metadata
- Authors
- Bossetti, C. A., Birdno, M. J., & Grill, W. M.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2007-12-17
- Volume
- 5
- Issue
- 1
- Pages
- 44-53
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2054864282
- Cited by
- 232
- References
- 18
- FWCI
- 1.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.