A user-friendly SSVEP-based brain–computer interface using a time-domain classifier
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
We introduce a user-friendly steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) system. Single-channel EEG is recorded using a low-noise dry electrode. Compared to traditional gel-based multi-sensor EEG systems, a dry sensor proves to be more convenient, comfortable and cost effective. A hardware system was built that displays four LED light panels flashing at different frequencies and synchronizes with EEG acquisition. The visual stimuli have been carefully designed such that potential risk to photosensitive people is minimized. We describe a novel stimulus-locked inter-trace correlation (SLIC) method for SSVEP classification using EEG time-locked to stimulus onsets. We studied how the performance of the algorithm is affected by different selection of parameters. Using the SLIC method, the average light detection rate is 75.8% with very low error rates (an 8.4% false positive rate and a 1.3% misclassification rate). Compared to a traditional frequency-domain-based method, the SLIC method is more robust (resulting in less annoyance to the users) and is also suitable for irregular stimulus patterns.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Welch, P. (1967) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1967.1161901 · Cited by 12,277
Hilbe, J. M. (2009) · Chapman & Hall/CRC eBooks · doi:10.1201/9781420075779 · Cited by 2,588
Design and implementation of a brain-computer interface with high transfer rates
Cheng, M., Gao, X., Gao, S., & Xu, D. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.803536 · Cited by 818 · cited 2×
“The frequency-domain-based SSVEP detection algorithms usually made use of the first [9, 12], or the first and the second [3, 6], or even the first three harmonics of the frequency at which the stimulus is presented [13].”
MethodBin, G., Gao, X., Yan, Z., Hong, B., & Gao, S. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046002 · Cited by 773 · cited 2×
“accuracy and ITR in a different way than [2].”
BackgroundResultBrain-computer interfaces based on the steady-state visual-evoked response
Middendorf, M., McMillan, G., Calhoun, G., & Jones, K. S. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847819 · Cited by 685 · cited 1×
“The frequency-domain-based SSVEP detection algorithms usually made use of the first [9, 12], or the first and the second [3, 6], or even the first three harmonics of the frequency at which the stimulus is presented [13].”
MethodA BCI-based environmental controller for the motion-disabled
Gao, X., Xu, D., Cheng, M., & Gao, S. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814449 · Cited by 637 · cited 1×
“The frequency-domain-based SSVEP detection algorithms usually made use of the first [9, 12], or the first and the second [3, 6], or even the first three harmonics of the frequency at which the stimulus is presented [13].”
MethodA practical VEP-based brain-computer interface
Wang, Y., Wang, R., Gao, X., Hong, B., & Gao, S. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875576 · Cited by 617
Müller-Putz, G. R., Scherer, R., Brauneis, C., & Pfurtscheller, G. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/008 · Cited by 534 · cited 2×
“The frequency-domain-based SSVEP detection algorithms usually made use of the first [9, 12], or the first and the second [3, 6], or even the first three harmonics of the frequency at which the stimulus is presented [13].”
MethodPhotic‐ and Pattern‐induced Seizures: A Review for the Epilepsy Foundation of America Working Group
Fisher, R. S., Harding, G., Erba, G., Barkley, G. L., & Wilkins, A. (2005) · Epilepsia · doi:10.1111/j.1528-1167.2005.31405.x · Cited by 427
Steady-State VEP-Based Brain-Computer Interface Control in an Immersive 3D Gaming Environment
Lalor, E. C., Kelly, S. P., Finucane, C., Burke, R., Smith, R., Reilly, R. B., & McDarby, G. (2005) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/asp.2005.3156 · Cited by 421
The brain response interface: communication through visually-induced electrical brain responses
Sutter, E. E. (1992) · Journal of Microcomputer Applications · doi:10.1016/0745-7138(92)90045-7 · Cited by 417 · cited 2×
“In [18] the author analyzed EEG in the time domain by computing the correlation between event-related potentials time-locked to the stimulus onset and a known response waveform (template) of the subject.”
BackgroundMethodHuman Cerebral Activation during Steady-State Visual-Evoked Responses
Pastor, M. A., Artieda, J., Arbizu, J., Valencia, M., & Masdeu, J. C. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-37-11621.2003 · Cited by 324 · cited 3×
“SSVEP is strongest in the visual cortex, when the stimulus is flashing at around 15 Hz [15].”
BackgroundMethodInfluentialAttentional Modulation of SSVEP Power Depends on the Network Tagged by the Flicker Frequency
Ding, J., Sperling, G., & Srinivasan, R. (2006) · Cerebral Cortex · doi:10.1093/cercor/bhj044 · Cited by 275 · cited 1×
“It is also worth noting that some researchers study SSVEP elicited by visual stimulus with irregular patterns, such as [4, 18].”
BackgroundUser adaptive BCIs: SSVEP and P300 based interfaces
Beverina, F., Palmas, G., Silvoni, S., Piccione, F., & Giove, S. (2003) · ARCA (Università Ca' Foscari Venezia) · Cited by 223
Visual Spatial Attention Control in an Independent Brain-Computer Interface
Kelly, S. P., Lalor, E. C., Finucane, C., McDarby, G., & Reilly, R. B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851510 · Cited by 176 · cited 1×
“The frequency-domain-based SSVEP detection algorithms usually made use of the first [9, 12], or the first and the second [3, 6], or even the first three harmonics of the frequency at which the stimulus is presented [13].”
MethodTelevised Material and Photosensitive Epilepsy
Harding, G. F. A., & Harding, P. (1999) · Epilepsia · doi:10.1111/j.1528-1157.1999.tb00909.x · Cited by 66 · cited 1×
“(4) It has been shown that when presented with flashing lights at 15–25 Hz, photosensitive subjects showed increased rate of EEG photosensitive responses [5, 7].”
BackgroundMüller-Putz, G., Eder, E., Wriessnegger, S. C., & Pfurtscheller, G. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.09.024 · Cited by 64
Cited by
Review of the BCI Competition IV
Tangermann, M., Müller, K.-R., Aertsen, A., Birbaumer, N., Braun, C., Brunner, C., Leeb, R., Mehring, C., Miller, K. J., Müller-Putz, G. R., et al. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00055 · Cited by 1,288
“WIRELESS AND DRY EEG SIGNALS We currently observe the upcoming of easy-to-mount dry electrode caps as either research prototypes (Popescu et al., 2007; Gargiulo et al., 2010; Luo and Sullivan, 2010; Saab et al., 2011; Zander et al., 2011) or purchasable products (e.”
MethodBrain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
The Berlin Brain–Computer Interface: Non-Medical Uses of BCI Technology
Blankertz, B., Tangermann, M., Vidaurre, C., Fazli, S., Sannelli, C., Haufe, S., Maeder, C., Ramsey, L., Sturm, I., Curio, G., et al. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00198 · Cited by 357
“Two dry sensor systems have been evaluated with respect to an SSVEP (Morgan et al., 1996; Middendorf et al., 2000; Cheng et al., 2002; Allison et al., 2008) paradigm: Luo and Sullivan (2010) used a single-channel dry sensor in a four-class setting.”
MethodKwak, N.-S., Müller, K.-R., & Lee, S.-W. (2017) · PLOS ONE · doi:10.1371/journal.pone.0172578 · Cited by 272
EEG-Based Brain-Computer Interfaces: A Thorough Literature Survey
Hwang, H.-J., Kim, S., Choi, S., & Im, C.-H. (2013) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2013.780869 · Cited by 257
“Sajda, & Parra, 2010; Dobrea & Dobrea, 2009; Hammon & de Sa, 2007; Luo & Sullivan, 2010; Tomioka & Muller, 2010).”
Metadata
- Authors
- Luo, A., & Sullivan, T. J.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2010-03-23
- Volume
- 7
- Issue
- 2
- Pages
- 026010
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2005634718
- Cited by
- 161
- References
- 17
- FWCI
- 9.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.