The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Does the ‘P300’ speller depend on eye gaze?
Open accessAbstract
Many people affected by debilitating neuromuscular disorders such as amyotrophic lateral sclerosis, brainstem stroke or spinal cord injury are impaired in their ability to, or are even unable to, communicate. A brain-computer interface (BCI) uses brain signals, rather than muscles, to re-establish communication with the outside world. One particular BCI approach is the so-called 'P300 matrix speller' that was first described by Farwell and Donchin (1988 Electroencephalogr. Clin. Neurophysiol. 70 510-23). It has been widely assumed that this method does not depend on the ability to focus on the desired character, because it was thought that it relies primarily on the P300-evoked potential and minimally, if at all, on other EEG features such as the visual-evoked potential (VEP). This issue is highly relevant for the clinical application of this BCI method, because eye movements may be impaired or lost in the relevant user population. This study investigated the extent to which the performance in a 'P300' speller BCI depends on eye gaze. We evaluated the performance of 17 healthy subjects using a 'P300' matrix speller under two conditions. Under one condition ('letter'), the subjects focused their eye gaze on the intended letter, while under the second condition ('center'), the subjects focused their eye gaze on a fixation cross that was located in the center of the matrix. The results show that the performance of the 'P300' matrix speller in normal subjects depends in considerable measure on gaze direction. They thereby disprove a widespread assumption in BCI research, and suggest that this BCI might function more effectively for people who retain some eye-movement control. The applicability of these findings to people with severe neuromuscular disabilities (particularly in eye-movements) remains to be determined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Receptive fields, binocular interaction and functional architecture in the cat’s visual cortex
Hubel, D. H., & Wiesel, T. N. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006837 · Cited by 13,680
Receptive fields of single neurones in the cat's striate cortex
Hubel, D. H., & Wiesel, T. N. (1959) · The Journal of Physiology · doi:10.1113/jphysiol.1959.sp006308 · Cited by 4,653
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
BCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024
Self-citationOn the utility of P3 amplitude as a measure of processing capacity
Kok, A. (2001) · Psychophysiology · doi:10.1017/s0048577201990559 · Cited by 1,766
The mental prosthesis: assessing the speed of a P300-based brain-computer interface
Donchin, E., Spencer, K. M., & Wijesinghe, R. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847808 · Cited by 1,222
Cortical sources of the early components of the visual evoked potential
Di Russo, F., Martínez, A., Sereno, M. I., Pitzalis, S., & Hillyard, S. A. (2002) · Human Brain Mapping · doi:10.1002/hbm.10010 · Cited by 1,170
American Electroencephalographic Society Guidelines for Standard Electrode Position Nomenclature
&NA; (1991) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199104000-00007 · Cited by 1,050
American Electroencephalographic Society guidelines for standard electrode position nomenclature
Sharbrough, F. W. (1991) · Journal of Clinical Neurophysiology · Cited by 918
Toward Brain-Computer Interfacing
(2007) · The MIT Press eBooks · doi:10.7551/mitpress/7493.001.0001 · Cited by 785
Cited by
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
(C)overt attention and visual speller design in an ERP-based brain-computer interface
Treder, M. S., & Blankertz, B. (2010) · Behavioral and Brain Functions · doi:10.1186/1744-9081-6-28 · Cited by 362
Flashing characters with famous faces improves ERP-based brain–computer interface performance
Kaufmann, T., Schulz, S. M., Grünzinger, C., & Kübler, A. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/5/056016 · Cited by 300
McCane, L. M., Heckman, S. M., McFarland, D. J., Townsend, G., Mak, J. N., Sellers, E. W., Zeitlin, D., Tenteromano, L. M., Wolpaw, J. R., & Vaughan, T. M. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.01.013 · Cited by 141
Self-citationEffects of training and motivation on auditory P300 brain-computer interface performance
Baykara, E., Ruf, C. A., Fioravanti, C., Käthner, I., Simon, N., Kleih, S. C., Kübler, A., & Halder, S. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.04.054 · Cited by 91
Metadata
- Authors
- Brunner, P., Joshi, S., Briskin, S., Wolpaw, J. R., Bischof, H., & Schalk, G.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2010-09-21
- Volume
- 7
- Issue
- 5
- Pages
- 056013
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2052870065
- Cited by
- 291
- References
- 41
- FWCI
- 19.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Does the ‘P300’ speller depend on eye gaze? https://app.cochat.ai/papers/10.1088/1741-2560/7/5/056013
- The paper
- Brunner, P., Joshi, S., Briskin, S., Wolpaw, J. R., Bischof, H., & Schalk, G. (2010). Does the ‘P300’ speller depend on eye gaze? Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/7/5/056013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.