P300-based brain–computer interface for environmental control: an asynchronous approach
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Brain-computer interface (BCI) systems allow people with severe motor disabilities to communicate and interact with the external world. The P300 potential is one of the most used control signals for EEG-based BCIs. Classic P300-based BCIs work in a synchronous mode; the synchronous control assumes that the user is constantly attending to the stimulation, and the number of stimulation sequences is fixed a priori. This issue is an obstacle for the use of these systems in everyday life; users will be engaged in a continuous control state, their distractions will cause misclassification and the speed of selection will not take into account users' current psychophysical condition. An efficient BCI system should be able to understand the user's intentions from the ongoing EEG instead. Also, it has to refrain from making a selection when the user is engaged in a different activity and it should increase or decrease its speed of selection depending on the current user's state. We addressed these issues by introducing an asynchronous BCI and tested its capabilities for effective environmental monitoring, involving 11 volunteers in three recording sessions. Results show that this BCI system can increase the bit rate during control periods while the system is proved to be very efficient in avoiding false negatives when the users are engaged in other tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“Brain–computer interfaces (BCIs) provide severely motor disabled people with an alternative channel to communicate and to control simple devices, independent of muscular activity (Wolpaw et al 2002).”
BackgroundFarwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
A comparison of classification techniques for the P300 Speller
Krusienski, D. J., Sellers, E. W., Cabestaing, F., Bayoudh, S., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/007 · Cited by 762
Toward enhanced p300 speller performance
Krusienski, D. J., Sellers, E. W., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.07.017 · Cited by 749 · cited 1×
“Scalp EEG potentials were recorded (g.MobiLab, gTec, Austria, sampling rate 256 Hz) from eight positions according to 10–10 standard (Fz, Cz, Pz, Oz, P3, P4, PO7 and PO8; Krusienski et al 2008).”
MethodHow many people are able to control a P300-based brain-computer interface (BCI)?
Guger, C., Daban, S., Sellers, E., Holzner, C., Krausz, G., Carabalona, R., Gramatica, F., & Edlinger, G. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.045 · Cited by 652 · cited 6×
“Five out of 11 subjects were naive to the P300-based BCI context.”
MethodInfluentialNijboer (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00055 · Cited by 323 · cited 1×
“Moreover, both the user’s psychophysical state (mood, fatigue, motivation; Nijboer et al 2010) and external factors (environmental conditions, stimulation modality, etc; Allison and Pineda 2003) can affect P300 morphology, and thus influence performance.”
Cited by
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
A Hybrid BCI System Combining P300 and SSVEP and Its Application to Wheelchair Control
Li, Y., Pan, J., Wang, F., & Yu, Z. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2270283 · Cited by 421
“Many studies have addressed the issue of asynchronous BCIs based on MI [6]–[10], SSVEP [11]–[13], P300 potential [14], [15].”
Background(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-52901-5.00006-x · Cited by 212
Brain–computer interface: trend, challenges, and threats
Maiseli, B., Abdalla, A. T., Massawe, L. V., Mbise, M., Mkocha, K., Nassor, N. A., Ismail, M., Michael, J., & Kimambo, S. (2023) · Brain Informatics · doi:10.1186/s40708-023-00199-3 · Cited by 168
Kaufmann, T., Herweg, A., & Kübler, A. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-7 · Cited by 159
“It is thus inherently necessary to implement an asynchronous system that will account for such situations [80-82].”
Background
Metadata
- Authors
- Aloise, F., Schettini, F., Aricò, P., Leotta, F., Salinari, S., Mattia, D., Babiloni, F., & Cincotti, F.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-03-24
- Volume
- 8
- Issue
- 2
- Pages
- 025025
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2034274649
- Cited by
- 104
- References
- 7
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: P300-based brain–computer interface for environmental control: an asynchronous approach. https://app.cochat.ai/papers/10.1088/1741-2560/8/2/025025
- The paper
- Aloise, F., Schettini, F., Aricò, P., Leotta, F., Salinari, S., Mattia, D., Babiloni, F., & Cincotti, F. (2011). P300-based brain–computer interface for environmental control: an asynchronous approach. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/8/2/025025
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.