Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.

A Hybrid BCI System Combining P300 and SSVEP and Its Application to Wheelchair Control

Li, Yuanqing, Pan, Jiahui, Wang, Fei, Yu, Zhuliang · 2013 · IEEE Transactions on Biomedical Engineering

Abstract

In this paper, a hybrid brain-computer interface (BCI) system combining P300 and steady-state visual evoked potential (SSVEP) is proposed to improve the performance of asynchronous control. The four groups of flickering buttons were set in the graphical user interface. Each group contained one large button in the center and eight small buttons around it, all of which flashed at a fixed frequency (e.g., 7.5 Hz) to evoke SSVEP. At the same time, the four large buttons of the four groups were intensified through shape and color changes in a random order to produce P300 potential. During the control state, the user focused on a desired group of buttons (target buttons) to evoke P300 potential and SSVEP, simultaneously. Discrimination between the control and idle states was based on the detection of both P300 and SSVEP on the same group of buttons. As an application, this method was used to produce a "go/stop" command in real-time wheelchair control. Several experiments were conducted, and data analysis results showed that combining P300 potential and SSVEP significantly improved the performance of the BCI system in terms of detection accuracy and response time.

Overview

Integrity signals

Registry

Crossref · 10.1109/tbme.2013.2270283

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 35 references

Cited by

See all 421

Metadata

Authors
Li, Y., Pan, J., Wang, F., & Yu, Z.
Affiliations
South China University of Technology (CN)
Venue
IEEE Transactions on Biomedical Engineering
Published
2013-11
Volume
60
Issue
11
Pages
3156-3166
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W1967545169
Cited by
421
References
35
Citations by year
2026: 11 · 2025: 37 · 2024: 39 · 2023: 38 · 2022: 43 · 2021: 41 · 2020: 36 · 2019: 35 · 2018: 37 · 2017: 33 · 2016: 30 · 2015: 18 · 2014: 21 · 2013: 1
FWCI
12.75
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
  • Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
Keywords
hybrid brain-computer interface, P300, steady-state visual evoked potentials, wheelchair control, asynchronous control, flicker paradigm, real-time control, detection accuracy, response time
MeSH terms
Adult, Biomedical Engineering, Electroencephalography, Evoked Potentials, Visual, Humans, ROC Curve, Signal Processing, Computer-Assisted, User-Computer Interface, Wheelchairs, Reproducibility of Results, Event-Related Potentials, P300, Young Adult, Brain-Computer Interfaces

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Hybrid BCI System Combining P300 and SSVEP and Its Application to Wheelchair Control. https://app.cochat.ai/papers/10.1109/tbme.2013.2270283
The paper
Li, Y., Pan, J., Wang, F., & Yu, Z. (2013). A Hybrid BCI System Combining P300 and SSVEP and Its Application to Wheelchair Control. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2013.2270283

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).