Garment-based detection of falls and activities of daily living using 3-axis MEMS accelerometer
Open accessThe DOI matches its Crossref record.
Abstract
This paper studied the detection of falls and activities of daily living (ADL) with two objectives: (1) minimum number of sensors for a broad range of activities and (2) maximize the comfort of the wearer for long term use. We used a garment to provide long term comfort for the wearer, with a 3-axis MEMS accelerometer on the shoulder position, as a wearable platform. ADL were detected in time-frequency domain and summation of absolute peak values of 3-D acceleration signals was used as feature in fall detection. 6 male and female subjects performed approximately five-hour long experiment. Sensitivity of 94.98% and specificity of 98.83% for altogether 1495 activities were achieved. Our garment-based detection system fulfilled the objective of providing the comfort of the wearer in long term monitoring of falls and ADL with high sensitivity. In fall detection, our device can summon medical assistances via SMS (Short Message Service). This detection system can raise fall alarm (fall SMS) automatically to individuals to get a shortened interval of the arrival of assistance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lee, K., Ni, X., Lee, J. Y., Arafa, H., Pe, D. J., Xu, S., Avila, R., Irie, M., Lee, J. H., Easterlin, R. L., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0480-6 · Cited by 349
Approaches and principles of fall detection for elderly and patient
Yu, X. (2008) · HealthCom 2008 - 10th International Conference on e-health Networking, Applications and Services · doi:10.1109/health.2008.4600107 · Cited by 328
iFall: An android application for fall monitoring and response
Sposaro, F., & Tyson, G. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5334912 · Cited by 317
Automatic Fall Monitoring: A Review
Pannurat, N., Thiemjarus, S., & Nantajeewarawat, E. (2014) · Sensors · doi:10.3390/s140712900 · Cited by 237
“…up to 100% Spe up to 100% Srinivasan et al. (2007) [38] 4 8 F5 TB, RB Sen = 94.79% Karantonis et al. (2006) [72] 3 9 F5, F10, F23 TB, RB Acc = 95.6% Nyan et al. (2006) [35] 3 6 N/A TB Sen = 100% Spe = 92.5%–97.5% Chen et al. (2005) [73] 2 2 F5, F28 TB, RB N/A Garrett Brown (2005) [74] 2 7 F5, F33,…”
BackgroundInfluentialPerFallD: A pervasive fall detection system using mobile phones
Dai, J., Bai, X., Yang, Z., Shen, Z., & Xuan, D. (2010) · 2010 8th IEEE International Conference on Pervasive Computing and Communications Workshops (PERCOM Workshops) · doi:10.1109/percomw.2010.5470652 · Cited by 235
“Kangas et al. in [14] propose four thresholds for total sum vector, dynamic sum vector, difference between the maximum and minimum acceleration values and vertical acceleration.”
Background
Metadata
- Authors
- Nyan, M. N., Tay, F. E. H., Manimaran, M., & Seah, K. H. W.
- Venue
- Journal of Physics: Conference Series
- Publisher
- IOP Publishing
- Published
- 2006-04-01
- Volume
- 34
- Pages
- 1059-1067
- ISSN
- 1742-6588 (ISSN-L)
- 1742-6596
- OpenAlex
- W1985088819
- Cited by
- 56
- References
- 0
- FWCI
- 3.11
- Type
- conference paper
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Garment-based detection of falls and activities of daily living using 3-axis MEMS accelerometer. https://app.cochat.ai/papers/10.1088/1742-6596/34/1/175
- The paper
- Nyan, M. N., Tay, F. E. H., Manimaran, M., & Seah, K. H. W. (2006). Garment-based detection of falls and activities of daily living using 3-axis MEMS accelerometer. Journal of Physics: Conference Series. https://doi.org/10.1088/1742-6596/34/1/175
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.