Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 216

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Maia X-ray fluorescence imaging: Capturing detail in complex natural samples

Open access
Ryan, C G, Siddons, D P, Kirkham, R, Li, Z Y, de Jonge, M D, Paterson, D J, Kuczewski, A, Howard, D L, Dunn, P A, Falkenberg, G, Boesenberg, U, De Geronimo, G, Fisher, L A, Halfpenny, A, Lintern, M J, Lombi, E, Dyl, K A, Jensen, M, Moorhead, G F, Cleverley, J S, Hough, R M, Godel, B, Barnes, S J, James, S A, Spiers, K M, Alfeld, M, Wellenreuther, G, Vukmanovic, Z, Borg, S · 2014 · Journal of Physics: Conference Series

Abstract

Motivated by the challenge of capturing complex hierarchical chemical detail in natural material from a wide range of applications, the Maia detector array and integrated realtime processor have been developed to acquire X-ray fluorescence images using X-ray Fluorescence Microscopy (XFM). Maia has been deployed initially at the XFM beamline at the Australian Synchrotron and more recently, demonstrating improvements in energy resolution, at the P06 beamline at Petra III in Germany. Maia captures fine detail in element images beyond 100 M pixels. It combines a large solid-angle annular energy-dispersive 384 detector array, stage encoder and flux counter inputs and dedicated FPGA-based real-time event processor with embedded spectral deconvolution. This enables high definition imaging and enhanced trace element sensitivity to capture complex trace element textures and place them in a detailed spatial context. Maia hardware and software methods provide per pixel correction for dwell, beam flux variation, dead-time and pileup, as well as off-line parallel processing for enhanced throughput. Methods have been developed for real-time display of deconvoluted SXRF element images, depth mapping of rare particles and the acquisition of 3D datasets for fluorescence tomography and XANES imaging using a spectral deconvolution method that tracks beam energy variation. © Published under licence by IOP Publishing Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1742-6596/499/1/012002

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 216

Metadata

Authors
Ryan, C. G., Siddons, D. P., Kirkham, R., Li, Z. Y., de Jonge, M. D., Paterson, D. J., Kuczewski, A., Howard, D. L., Dunn, P. A., Falkenberg, G., Boesenberg, U., De Geronimo, G., Fisher, L. A., Halfpenny, A., Lintern, M. J., Lombi, E., Dyl, K. A., Jensen, M., Moorhead, G. F., Cleverley, J. S., Hough, R. M., Godel, B., Barnes, S. J., James, S. A., Spiers, K. M., Alfeld, M., Wellenreuther, G., Vukmanovic, Z., & Borg, S.
Venue
Journal of Physics: Conference Series
Published
2014-04-03
Volume
499
Pages
012002
ISSN
  • 1742-6588 (ISSN-L)
  • 1742-6596
OpenAlex
W2088108206
Cited by
216
References
1
FWCI
42.97
Type
conference paper
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Maia X-ray fluorescence imaging: Capturing detail in complex natural samples. https://app.cochat.ai/papers/10.1088/1742-6596/499/1/012002
The paper
Ryan, C. G., Siddons, D. P., Kirkham, R., Li, Z. Y., de Jonge, M. D., Paterson, D. J., Kuczewski, A., Howard, D. L., Dunn, P. A., Falkenberg, G., Boesenberg, U., De Geronimo, G., Fisher, L. A., Halfpenny, A., Lintern, M. J., Lombi, E., Dyl, K. A., Jensen, M., Moorhead, G. F., . . . Borg, S. (2014). Maia X-ray fluorescence imaging: Capturing detail in complex natural samples. Journal of Physics: Conference Series. https://doi.org/10.1088/1742-6596/499/1/012002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.