Partial Discharge Characteristics in Composite Insulation Systems with PPLP for HTS Cable
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The electrical insulation system of high-temperature superconducting (HTS) cable consists of liquid nitrogen (N 2 (l)) and polypropylene laminated paper (PPLP). Partial discharge (PD) may occur in butt gaps of the insulation layers and its characteristics imply the insulation performance of HTS cables. N 2 (l) cooling system is installed in the power system and N 2 (l) will flow through the cables during the system operation. Filling the HTS cable with N 2 (l) in order to perform pre-shipment inspection is time-consuming and costly for cable manufacturers. Therefore, they are trying to find a cost effective method for pre-shipment inspections. One alternative is to use high pressure gaseous nitrogen (N 2 (g)) instead of N 2 (l). This article investigates PD characteristics such as PD inception electric field (PDIE) and PD extinction electric field (PDEE) in butt gaps of HTS cables in 0.1 to 0.3 MPa and 0.1 MPa to 1.0 MPa N 2 (g) environments. For assessing the surface/volume effects, PD characteristics are measured with changing the size of butt gaps. It turns out that PDIE and PDEE in N 2 (g) are linearly correlated with those in N 2 (l) at any gas pressure in our testing, and PDIE in 1.0 MPa N 2 (g) is almost 30% of that in 0.2 MPa It suggests that PD characteristics in N 2 (l) can be extrapolated from those in N 2 (g).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures









Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“The insulation failure caused by the high-frequency PWM waveform reduces the life cycle due to the accelerated aging, electrical stress, overvoltage, and heating [154].”
From State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements (2020) · cites this paper as [154]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
R&D of a 500 m superconducting cable in japan
Ueda, K., Tsukamoto, O., Nagaya, S., Kimura, H., & Akita, S. (2003) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2003.812973 · Cited by 35 · cited 1×
“This small reactance contributes to the improvement of voltage and synchronous stability of power system [1].”
BackgroundCharacterization of partial discharge in composite insulation system with PPLPR for HTS cable
Rezaeifar, F., Suzuki, Y., Kumada, A., Hidaka, K., Nishimura, T., & Masuda, T. (2010) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2010.5658225 · Cited by 12
Self-citation
Research works printed but not linked: 1
- Hayakawa N, Yamaguchi R, Kojima H, Endo F and Okubo 2008 IEEE Inter, Confe. On. Dielecric Liquids. ICDL 2008. pp.1-4 11th European Conference on Applied Superconductivity (EUCAS2013) IOP Publishing Journal of Physics: Conference Series 507 (2014) 032024 doi:10.1088/1742-6596/507/3/032024
Cited by
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
“Partial discharge (PD) is the main responsible factor for occurring the insulation deterioration in HV systems or LV ones where overvoltage or surge may take place [155].”
BackgroundTemperature-Dependent Dielectric Properties of Polyimide (PI) and Polyamide (PA) Nanocomposites
Cook, J. T., Hones, H., Mahon, J., Yu, L., Krchnavek, R. R., & Xue, W. (2021) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2021.3098233 · Cited by 21
Effect of liquid nitrogen on surface charge of polypropylene film under DC and pulse voltages
Du, B. X., Huang, P. H., Xing, Y., & Jin, J. X. (2015) · International Conference on Applied Superconductivity and Electromagnetic Devices · doi:10.1109/asemd.2015.7453584 · Cited by 2
“, and the latter investigated the space charge of PPLP with different DC voltage amplitude and charging time, and the practicability of PPLP in HTS cable was convinced [4,5].”
BackgroundBORYN, H. (2015) · Applied Entomology and Zoology · doi:10.17274/aez.2015.19.04
Metadata
- Authors
- Kikuchi, Y., Yamashita, K., Kumada, A., Hidaka, K., Tatamidani, K., & Masuda, T.
- Affiliations
- The University of Tokyo (JP)
- Sumitomo Electric Industries (Japan) (JP)
- Venue
- Journal of Physics: Conference Series
- Publisher
- IOP Publishing
- Published
- 2014-05-12
- Volume
- 507
- Issue
- 3
- Pages
- 032024
- ISSN
- 1742-6588 (ISSN-L)
- 1742-6596
- OpenAlex
- W2319097895
- Cited by
- 4
- References
- 2
- Citations by year
- 2021: 1 · 2020: 1 · 2015: 2
- FWCI
- 2.78
- Type
- conference paper
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- cc-by
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- creativecommons.org/licenses/by/3.0/ (vor)
- Locations
- Journal of Physics Conference Series (publishedVersion, cc-by)
- Funders
- Japan Society for the Promotion of Science (25289072)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › High voltage insulation and dielectric phenomena
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Transformer Diagnostics and Insulation
- Keywords
- partial discharge, high-temperature superconducting cables, polypropylene laminated paper, composite insulation, liquid nitrogen cooling, pre-shipment inspection, insulation performance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Partial Discharge Characteristics in Composite Insulation Systems with PPLP for HTS Cable. https://app.cochat.ai/papers/10.1088/1742-6596/507/3/032024
- The paper
- Kikuchi, Y., Yamashita, K., Kumada, A., Hidaka, K., Tatamidani, K., & Masuda, T. (2014). Partial Discharge Characteristics in Composite Insulation Systems with PPLP for HTS Cable. Journal of Physics: Conference Series. https://doi.org/10.1088/1742-6596/507/3/032024
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.