NEST: a comprehensive model for scintillation yield in liquid xenon
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
A comprehensive model for explaining scintillation yield in liquid xenon is introduced. We unify various definitions of work function which abound in the literature and incorporate all available data on electron recoil scintillation yield. This results in a better understanding of electron recoil, and facilitates an improved description of nuclear recoil. An incident gamma energy range of O (1 keV) to O (1 MeV) and electric fields between 0 and O (10 kV/cm) are incorporated into this heuristic model. We show results from a Geant4 implementation, but because the model has a few free parameters, implementation in any simulation package should be simple. We use a quasi-empirical approach with an objective of improving detector calibrations and performance verification. The model will aid in the design and optimization of future detectors. This model is also easy to extend to other noble elements. In this paper we lay the foundation for an exhaustive simulation code which we call NEST (Noble Element Simulation Technique).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106 · cited 1×
“should exclusively produce ER [10, 12]. Our model is ultimately an approximation because Geant4 does not accurately simulate electron production (tertiary, quaternary generations, etc.) below 250 eV [5], unlike other software packages with more precise low-energy electron physics, such as PENELOPE [10, 32]. However, w…”
MethodGeant4 developments and applications
Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce Dubois, P., Asai, M., Barrand, G., Capra, R., Chauvie, S., Chytracek, R., et al. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.869826 · Cited by 6,946
First Dark Matter Results from the XENON100 Experiment
Aprile, E., Arisaka, K., Arneodo, F., Askin, A., Baudis, L., Behrens, A., Bokeloh, K., Brown, E., Cardoso, J. M. R., Choi, B., et al. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.131302 · Cited by 431 · cited 2×
“two predictions in Figure 9 are consistent with recent measurements by Plante et al. [60] and Manzur et al. [8], but in direct conflict with the older claims of Sorensen et al. [61] and Aprile et al. [58]. Because NR yields change very weakly with field [22, 54], we did not initially investigate field dependence. Dahl’s…”
BackgroundResultLiquid xenon detectors for particle physics and astrophysics
Aprile, E., & Doke, T. (2010) · Reviews of Modern Physics · doi:10.1103/revmodphys.82.2053 · Cited by 317 · cited 10×
“2The latter effect is well-known to be small, sub-Poissonian in fact [2, 10, 26].”
BackgroundMethodInfluentialComparison of Geant4 electromagnetic physics models against the NIST reference data
Amako, K., Guatelli, S., Ivanchenko, V. N., Maire, M., Mascialino, B., Murakami, K., Nieminen, P., Pandola, L., Parlati, S., Pia, M. G., et al. (2005) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2005.852691 · Cited by 191
Design and performance of the XENON10 dark matter experiment
Aprile, E., Angle, J., Arneodo, F., Baudis, L., Bernstein, A., Bolozdynya, A. I., Brusov, P. N., Coelho, L., Dahl, C. E., de Viveiros, L., et al. (2011) · Astroparticle Physics · doi:10.1016/j.astropartphys.2011.01.006 · Cited by 186 · cited 1×
“Doke et al. [4] and Dahl [10]: 13.8 0.9 and 13.7 0.2 eV. At least three other values exist, but were not included in the average: 14.0 eV because it was reported without a clearly stated uncertainty [40], 13.46 0.29 eV [27] due to a calibration issue expressed by Dahl [25] (but it was still used to estimate a 122 keV…”
BackgroundInfluentialThe scintillation and ionization yield of liquid xenon for nuclear recoils
Sørensen, P., Manzur, A., Dahl, C. E., Angle, J., Aprile, E., Arneodo, F., Baudis, L., Bernstein, A., Bolozdynya, A. I., Coelho, L., et al. (2009) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2008.12.197 · Cited by 95
Spatially uniform calibration of a liquid xenon detector at low energies using K83mr
Manalaysay, A., Undagoitia, T. M., Askin, A., Baudis, L., Behrens, A., Ferella, A. D., Kish, A., Lebeda, O., Santorelli, R., Vénos, D., et al. (2010) · Review of Scientific Instruments · doi:10.1063/1.3436636 · Cited by 78
Cited by
First Results from the LUX Dark Matter Experiment at the Sanford Underground Research Facility
Akerib, D. S., Araújo, H. M., Bai, X., Bailey, A. J., Balajthy, J., Bedikian, S., Bernard, E., Bernstein, A., Bolozdynya, A., Bradley, A., et al. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.091303 · Cited by 1,599
Self-citationResults from a Search for Dark Matter in the Complete LUX Exposure
Akerib, D. S., Alsum, S., Araújo, H. M., Bai, X., Bailey, A. J., Balajthy, J., Beltrame, P., Bernard, E. P., Bernstein, A., Biesiadzinski, T. P., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.021303 · Cited by 1,553
Self-citationDark Matter Results from 225 Live Days of XENON100 Data
Aprile, E., Alfonsi, M., Arisaka, K., Arneodo, F., Balan, C., Baudis, L., Bauermeister, B., Behrens, A., Beltrame, P., Bokeloh, K., et al. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.181301 · Cited by 1,394
DARWIN: towards the ultimate dark matter detector
Aalbers, J., Agostini, F., Alfonsi, M., Amaro, F. D., Amsler, C., Aprile, E., Arazi, L., Arneodo, F., Barrow, P., Baudis, L., et al. (2016) · Journal of Cosmology and Astroparticle Physics · doi:10.1088/1475-7516/2016/11/017 · Cited by 582
Direct detection of WIMP dark matter: concepts and status
Schumann, M. (2019) · Journal of Physics G: Nuclear and Particle Physics · doi:10.1088/1361-6471/ab2ea5 · Cited by 480
Akerib, D. S., Araújo, H. M., Bai, X., Bailey, A. J., Balajthy, J., Beltrame, P., Bernard, E. P., Bernstein, A., Biesiadzinski, T. P., Boulton, E. M., et al. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.161301 · Cited by 386
Self-citationDirect detection of dark matter—APPEC committee report*
Billard, J., Boulay, M., Cebrián, S., Covi, L., Fiorillo, G., Green, A., Kopp, J., Majorovits, B., Palladino, K., Petricca, F., et al. (2022) · Reports on Progress in Physics · doi:10.1088/1361-6633/ac5754 · Cited by 302
nEXO: neutrinoless double beta decay search beyond 1028 year half-life sensitivity
Adhikari, G., Al Kharusi, S., Angelico, E., Anton, G., Arnquist, I. J., Badhrees, I., Bane, J., Belov, V, Bernard, E. P., Bhatta, T., et al. (2022) · Journal of Physics G: Nuclear and Particle Physics · doi:10.1088/1361-6471/ac3631 · Cited by 161
Metadata
- Authors
- Szydagis, M., Barry, N., Kazkaz, K., Mock, J., Stolp, D., Sweany, M., Tripathi, M., Uvarov, S., Walsh, N., & Woods, M.
- Venue
- Journal of Instrumentation
- Publisher
- IOP Publishing
- Published
- 2011-10-03
- Volume
- 6
- Issue
- 10
- Pages
- P10002-P10002
- ISSN
- 1748-0221 (ISSN-L)
- OpenAlex
- W2598381629
- Cited by
- 234
- References
- 8
- FWCI
- 10.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.