GoQBot: a caterpillar-inspired soft-bodied rolling robot
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Rolling locomotion using an external force such as gravity has evolved many times. However, some caterpillars can curl into a wheel and generate their own rolling momentum as part of an escape repertoire. This change in body conformation occurs well within 100 ms and generates a linear velocity over 0.2 m s(-1), making it one of the fastest self-propelled wheeling behaviors in nature. Inspired by this behavior, we construct a soft-bodied robot to explore the dynamics and control issues of ballistic rolling. This robot, called GoQBot, closely mimics caterpillar rolling. Analyzing the whole body kinematics and 2D ground reaction forces at the robot ground anchor reveals about 1G of acceleration and more than 200 rpm of angular velocity. As a novel rolling robot, GoQBot demonstrates how morphing can produce new modes of locomotion. Furthermore, mechanical coupling of the actuators improves body coordination without sensory feedback. Such coupling is intrinsic to soft-bodied animals because there are no joints to isolate muscle-generated movements. Finally, GoQBot provides an estimate of the mechanical power for caterpillar rolling that is comparable to that of a locust jump. How caterpillar musculature produces such power in such a short time is yet to be discovered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermomechanical aspects of NiTi
Shaw, J. A. (1995) · Journal of the Mechanics and Physics of Solids · doi:10.1016/0022-5096(95)00024-d · Cited by 971
The energetics of the jump of the locust Schistocerca gregaria
Bennet-Clark, H. C. (1975) · Journal of Experimental Biology · doi:10.1242/jeb.63.1.53 · Cited by 450
Contraction Dynamics and Power Output of Skeletal Muscle
Josephson, R. K. (1993) · Annual Review of Physiology · doi:10.1146/annurev.ph.55.030193.002523 · Cited by 364
Power and efficiency of insect flight muscle
Ellington, C. P. (1985) · Journal of Experimental Biology · doi:10.1242/jeb.115.1.293 · Cited by 215
Simulations of localized thermo-mechanical behavior in a NiTi shape memory alloy
Shaw, J. A. (2000) · International Journal of Plasticity · doi:10.1016/s0749-6419(99)00075-3 · Cited by 198
Crawling and Jumping by a Deformable Robot
Sugiyama, Y., & Hirai, S. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906065386 · Cited by 198
Michaud, F., & Caron, S. (2002) · Autonomous Robots · doi:10.1023/a:1014005728519 · Cited by 163
New Robotics: Design Principles for Intelligent Systems
Pfeifer, R., Iida, F., & Bongard, J. (2005) · Artificial Life · doi:10.1162/1064546053279017 · Cited by 146
Walters, E. T., Illich, P. A., Weeks, J. C., & Lewin, M. R. (2001) · Journal of Experimental Biology · doi:10.1242/jeb.204.3.457 · Cited by 119
Brackenbury, J. H. (1997) · Nature · doi:10.1038/37253 · Cited by 116
Fast locomotion in caterpillars
Brackenbury, J. H. (1999) · Journal of Insect Physiology · doi:10.1016/s0022-1910(98)00157-7 · Cited by 101
Energetics of Caterpillar Locomotion: Biomechanical Constraints of a Hydraulic Skeleton
Casey, T. M. (1991) · Science · doi:10.1126/science.252.5002.112 · Cited by 71
LaBarbera, M. (1983) · The American Naturalist · doi:10.1086/284068 · Cited by 67
Woods, W. A., Fusillo, S. J., & Trimmer, B. A. (2008) · Journal of Experimental Biology · doi:10.1242/jeb.006031 · Cited by 49
Self-citation
Cited by
Design, fabrication and control of soft robots
Rus, D., & Tolley, M. T. (2015) · Nature · doi:10.1038/nature14543 · Cited by 5,825
An integrated design and fabrication strategy for entirely soft, autonomous robots
Wehner, M., Truby, R. L., Fitzgerald, D. J., Mosadegh, B., Whitesides, G. M., Lewis, J. A., & Wood, R. J. (2016) · Nature · doi:10.1038/nature19100 · Cited by 2,127
Soft robotics: a bioinspired evolution in robotics
Kim, S., Laschi, C., & Trimmer, B. (2013) · Trends in Biotechnology · doi:10.1016/j.tibtech.2013.03.002 · Cited by 2,092
Self-citationSoft robotic glove for combined assistance and at-home rehabilitation
Polygerinos, P., Wang, Z., Galloway, K. C., Wood, R. J., & Walsh, C. J. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.014 · Cited by 1,617
Pneumatic Networks for Soft Robotics that Actuate Rapidly
Mosadegh, B., Polygerinos, P., Keplinger, C., Wennstedt, S., Shepherd, R. F., Gupta, U., Shim, J., Bertoldi, K., Walsh, C. J., & Whitesides, G. M. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201303288 · Cited by 1,607
Metadata
- Authors
- Lin, H.-T., Leisk, G. G., & Trimmer, B.
- Venue
- Bioinspiration & Biomimetics
- Publisher
- IOP Publishing
- Published
- 2011-04-26
- Volume
- 6
- Issue
- 2
- Pages
- 026007
- ISSN
- 1748-3182 (ISSN-L)
- 1748-3190
- OpenAlex
- W2010745100
- Cited by
- 690
- References
- 14
- FWCI
- 10.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.