Fabrication, testing and modeling of a new flexible armor inspired from natural fish scales and osteoderms
Open accessThe DOI matches its Crossref record; 20 of the 22 references it cites were found in a registry or an index; 1 of the 9 sources its claims cite were checked for support.
Abstract
Crocodiles, armadillo, turtles, fish and many other animal species have evolved flexible armored skins in the form of hard scales or osteoderms, which can be described as hard plates of finite size embedded in softer tissues. The individual hard segments provide protection from predators, while the relative motion of these segments provides the flexibility required for efficient locomotion. In this work, we duplicated these broad concepts in a bio-inspired segmented armor. Hexagonal segments of well-defined size and shape were carved within a thin glass plate using laser engraving. The engraved plate was then placed on a soft substrate which simulated soft tissues, and then punctured with a sharp needle mounted on a miniature loading stage. The resistance of our segmented armor was significantly higher when smaller hexagons were used, and our bio-inspired segmented glass displayed an increase in puncture resistance of up to 70% compared to a continuous plate of glass of the same thickness. Detailed structural analyses aided by finite elements revealed that this extraordinary improvement is due to the reduced span of individual segments, which decreases flexural stresses and delays fracture. This effect can however only be achieved if the plates are at least 1000 stiffer than the underlying substrate, which is the case for natural armor systems. Our bio-inspired system also displayed many of the attributes of natural armors: flexible, robust with 'multi-hit' capabilities. This new segmented glass therefore suggests interesting bio-inspired strategies and mechanisms which could be systematically exploited in high-performance flexible armors. This study also provides new insights and a better understanding of the mechanics of natural armors such as scales and osteoderms.
Overview
CoChat Summary
TL;DR
The paper fabricates a bio-inspired segmented armor of laser-engraved hexagonal glass plates on a soft rubber substrate and tests it under puncture. It finds that smaller hexagons can increase puncture resistance by up to 70% over continuous glass, provided the plate/substrate stiffness contrast is high enough.
Key findings
- Continuous 150 µm glass plate failed at \(P_{\text{crit}} \approx 6\) N and \(W_p \approx 1\) mJ; segmented glass with \(R = 1\) mm reached \(P_{\text{crit}} = 9\) N and \(W_p = 7\) mJ, a 70% improvement in puncture resistance. For the segmented case shown in figure 4, work to puncture was seven times greater than continuous.
- Hexagons \(R \ge 6\) mm behaved like a continuous plate; \(R < 1\) mm tilted around the needle, giving \(P < 1\) N, a detrimental failure mode. The transition from fracture to tilting occurred at about \(R = 1\) mm.
- Finite element modeling attributed the improvement to the reduced flexural span of smaller plates; the effect requires plates at least 1000 times stiffer than the substrate. The segmented plate also showed “multi-hit” capability: puncturing four different hexagons did not compromise the rest of the plate, and flexibility was demonstrated by bending a silicone film after hexagons detached; excessive bending detached plates from the substrate.
Methods
- Fabrication: 150 µm borosilicate glass, modulus 63 GPa, laser-engraved with a Vitromark ultraviolet laser at 100 mW into hexagonal patterns (edge length \(R = 0.25\)–6 mm; engraved lines made of microcracks 5 µm apart), placed on a silicone rubber substrate with modulus 1 MPa (63,000 times less stiff than glass).
- Puncture tests: sharp steel needle tip radius 25 µm on a miniature loading stage with a 110 N load cell, displacement rate 0.005 mm s\(^{-1}\), contacting the central region of a hexagon; continuous glass was tested as reference; six samples were tested for each hexagon size.
- Modeling: axisymmetric finite element models (ANSYS) of continuous and circular plates on a soft substrate, with a point force and bonded interface; actual properties used were \(E_p = 63\) GPa, \(E_s = 1.3\) MPa, \(\nu_p = 0.2\), \(\nu_s = 0.49\); a Neo-Hookean rubber model gave the same results.
Limitations
- Stated in paper: the improvement requires plates at least 1000 times stiffer than the substrate; when plates become too small they tilt, a highly detrimental failure mode; adhesion between plate and substrate probably plays a critical role and is being explored.
- Stated in paper: hexagonal plates were approximated as circular plates in axisymmetric finite element models; the needle was modeled as a point force and contact stress details were not captured; the interface was modeled as bonded.
- Evident from text: the study tests one glass-on-rubber system under quasi-static puncture (0.005 mm s\(^{-1}\)); no impact or ballistic validation is reported, despite mention of impact benefits.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
1 Valid · 0 Not valid · 6 Not checked · 39 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“As a general rule, natural protective systems are also much stiffer and harder than the underlying soft tissues.”
What the sources say
- Partly supportedcites [11] [11] Barthelat F 2010 Nacre from mollusk shells: a model for high-performance structural materials Bioinspir. Biomim. 5 035001 - sourceExperimental — accuracy not yet measured
The Introduction describes the mollusk shell as protecting the animal’s soft body and says the shell has high stiffness and hardness. The Mollusk shells overview likewise calls shells stiff and hard. These passages support mollusk shells as an example, but not the claim’s general rule about natural protective systems. (LLM, conf=0.83)
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Figure 10( a ) shows a segmented plate ( R = 1.5 mm) which was punctured four times at different locations, with an equally high performance for each puncture.”
plainSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“which is 63 000 times less stiff than the of glass plate”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“we measured a modulus of 63 GPa for this particular glass using a three-point bending configuration”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Interestingly, the critical force required to puncture the individual hexagon ( P crit = 7.5 N) was higher than that for the continuous glass plate.”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
28 more claims
Create a free account to see all 46 claims and every source verdict.
- It may state two separate claims as one. 10
- The quote only partly states this claim. 1
- Probably not a substantial claim. 3
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ 1. Introduction · p. 2
“For example, individual fish scales are multilayered plates which are 10 000 times stiffer than the underlying skin and tissues [3].”
§ 1. Introduction · p. 3
“Fish scales are five orders of magnitude stiffer than the underlying skin and muscles.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ 3. Puncture tests · p. 5
“Figure 4. ( a ) Typical puncture force-displacement responses for a continuous glass plate and for segmented glass plate with R = 1.5 mm;”
§ 3. Puncture tests · p. 5
“Figure 4 shows typical results for the continuous glass plate, and for a segmented glass plate with hexagonal patterns ( R = 2 mm).”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ 3. Puncture tests · p. 6
“For hexagonal plates smaller than R = 1 mm, another failure mode prevailed: the individual hexagon tilted around the needle and largely lost contact with the substrate (figure 6( c )).”
§ 4. Modeling flexural stresses · p. 6
“Failure mode for ( c ) large hexagonal plates ( R > 1 mm, red dots) and ( d ) small hexagonal plates ( R < 1 mm, blue dots).”
Citations
Cites
Anomalous transport in the crowded world of biological cells
Höfling, F., & Franosch, T. (2013) · MPG.PuRe (Max Planck Society) · Cited by 773
Biological materials: Functional adaptations and bioinspired designs
Chen, P.-Y., McKittrick, J., & Meyers, M. A. (2012) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.03.001 · Cited by 766
Roeder, B. A., Kokini, K., Sturgis, J. E., Robinson, J. P., & Voytik-Harbin, S. L. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1449904 · Cited by 620
Materials design principles of ancient fish armour
Bruet, B. J. F., Song, J., Boyce, M. C., & Ortiz, C. (2008) · Nature Materials · doi:10.1038/nmat2231 · Cited by 447
Biomimetics—using nature to inspire human innovation
Bar-Cohen, Y. (2006) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/1/1/p01 · Cited by 430
Yang, W., Chen, I. H., Gludovatz, B., Zimmermann, E. A., Ritchie, R. O., & Meyers, M. A. (2013) · Advanced Materials · doi:10.1002/adma.201202713 · Cited by 426
Structure and Mechanical Performance of a “Modern” Fish Scale
Zhu, D., Ortega, C. F., Motamedi, R., Szewciw, L., Vernerey, F., & Barthelat, F. (2012) · Advanced Engineering Materials · doi:10.1002/adem.201180057 · Cited by 247
Self-citationNacre from mollusk shells: a model for high-performance structural materials
Barthelat, F. (2010) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/5/3/035001 · Cited by 241
Self-citationDesigning architectured materials
Ashby, M. (2013) · Scripta Materialia · doi:10.1016/j.scriptamat.2012.04.033 · Cited by 227
Armadillo armor: Mechanical testing and micro-structural evaluation
Chen, I. H., Kiang, J. H., Correa, V., Lopez, M. I., Chen, P.-Y., McKittrick, J., & Meyers, M. A. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2010.12.013 · Cited by 199
Research works printed but not linked: 4
- [9] Colorado State University 2012 Warren and Genevieve Grast Phtographic Collection, Archieves and Special Collections (Colorado State University) -
- [13] Broos J P F and Gunters R 2007 Study on the ballistic performance of monolithic ceramic plates 23rd Int. Symp. on Ballistics (Tarragona, Spain) pp 1561-7 -
- [14] Larsen II J A and Cross C W 2007 Composite segmented flexible armor US Patent Specification 2007 / 0234458 A1 -
- [16] Neal M L and Bain A D 2001 Method and apparatus for defeating high-velocity projectiles US Patent Specification 6170378 B1 -
Cited by
Ha, N. S., & Lu, G. (2020) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2019.107496 · Cited by 1,175
Vibration isolation by exploring bio-inspired structural nonlinearity
Wu, Z., Jing, X., Bian, J., Li, F., & Allen, R. (2015) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/10/5/056015 · Cited by 222
Inspiration from Nature's body armours – A review of biological and bioinspired composites
Ghazlan, A., Ngo, T., Tan, P., Xie, Y. M., Tran, P., & Donough, M. (2021) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2020.108513 · Cited by 211
Yang, X., Ma, J., Shi, Y., Sun, Y., & Yang, J. (2017) · Materials & Design · doi:10.1016/j.matdes.2017.09.040 · Cited by 195
Biomimetic armour design strategies for additive manufacturing: A review
Islam, M. K., Hazell, P. J., Escobedo, J. P., & Wang, H. (2021) · Materials & Design · doi:10.1016/j.matdes.2021.109730 · Cited by 190
Metadata
- Authors
- Chintapalli, R. K., Mirkhalaf, M., Dastjerdi, A. K., & Barthelat, F.
- Affiliations
- McGill University (CA)
- ORCID
- Mirkhalaf, Mohammad
- Venue
- Bioinspiration & Biomimetics
- Publisher
- IOP Publishing
- Published
- 2014-03-11
- Volume
- 9
- Issue
- 3
- Pages
- 036005
- ISSN
- 1748-3182 (ISSN-L)
- 1748-3190
- OpenAlex
- W2046400205
- Cited by
- 128
- References
- 22
- Citations by year
- 2026: 15 · 2025: 11 · 2024: 5 · 2023: 6 · 2022: 13 · 2021: 12 · 2020: 16 · 2019: 10 · 2018: 10 · 2017: 13 · 2016: 10 · 2015: 4 · 2014: 3
- FWCI
- 11.63
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- iopscience.iop.org/page/copyright (vor)
- Locations
- Bioinspiration & Biomimetics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Natural Sciences and Engineering Research Council of Canada
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
- Physical Sciences › Materials Science › Biomaterials › Calcium Carbonate Crystallization and Inhibition
- Physical Sciences › Engineering › Mechanical Engineering › Cellular and Composite Structures
- Keywords
- fish scales, osteoderms, puncture resistance, bending stress, fracture, soft substrates, laser engraving
- MeSH terms
- Animals, Armadillos, Fishes, Hardness, Materials Testing, Reptiles, Skin, Stress, Mechanical, Surface Properties, Silicates, Compressive Strength, Biomimetic Materials, Elastic Modulus
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-12, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-12 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fabrication, testing and modeling of a new flexible armor inspired from natural fish scales and osteoderms. https://app.cochat.ai/papers/10.1088/1748-3182/9/3/036005
- The paper
- Chintapalli, R. K., Mirkhalaf, M., Dastjerdi, A. K., & Barthelat, F. (2014). Fabrication, testing and modeling of a new flexible armor inspired from natural fish scales and osteoderms. Bioinspiration & Biomimetics. https://doi.org/10.1088/1748-3182/9/3/036005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.