The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Tensile Mechanical Properties of Three-Dimensional Type I Collagen Extracellular Matrices With Varied Microstructure
Abstract
The importance and priority of specific micro-structural and mechanical design parameters must be established to effectively engineer scaffolds (biomaterials) that mimic the extracellular matrix (ECM) environment of cells and have clinical applications as tissue substitutes. In this study, three-dimensional (3-D) matrices were prepared from type I collagen, the predominant compositional and structural component of connective tissue ECMs, and structural-mechanical relationships were studied. Polymerization conditions, including collagen concentration (0.3–3 mg/mL) and pH (6–9), were varied to obtain matrices of collagen fibrils with different microstructures. Confocal reflection microscopy was used to assess specific micro-structural features (e.g., diameter and length) and organization of component fibrils in 3-D. Microstructural analyses revealed that changes in collagen concentration affected fibril density while maintaining a relatively constant fibril diameter. On the other hand, both fibril length and diameter were affected by the pH of the polymerization reaction. Mechanically, all matrices exhibited a similar stress-strain curve with identifiable “toe,” “linear,” and “failure” regions. However, the linear modulus and failure stress increased with collagen concentration and were correlated with an increase in fibril density. Additionally, both the linear modulus and failure stress showed an increase with pH, which was related to an increased fibril length and a decreased fibril diameter. The tensile mechanical properties of the collagen matrices also showed strain rate dependence. Such fundamental information regarding the 3-D microstructural-mechanical properties of the ECM and its component molecules are important to our overall understanding of cell-ECM interactions (e.g., mechanotransduction) and the development of novel strategies for tissue repair and replacement.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Materials Science and Engineering: An Introduction
Callister, W. D. (1985) · Cited by 5,351
Design of an artificial skin. I. Basic design principles
Yannas, I. V., & Burke, J. F. (1980) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820140108 · Cited by 1,044
Design of an artificial skin. I. Basic design principles
Yannas, I. V., & Burke, J. F. (1980) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820140314 · Cited by 889
[2] Preparation and characterization of the different types of collagen
Miller, E. J., & Kent Rhodes, R. (1982) · Methods in Enzymology · doi:10.1016/0076-6879(82)82059-4 · Cited by 752
Collagen; ultrastructure and its relation to mechanical properties as a function of ageing
Diamant, J., Keller, A., Baer, E., Litt, M., & Arridge, R. G. C. (1972) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1972.0019 · Cited by 553
Isometric contraction by fibroblasts and endothelial cells in tissue culture: a quantitative study
Kolodney, M., & Wysolmerski, R. (1992) · The Journal of cell biology · doi:10.1083/jcb.117.1.73 · Cited by 447
Wood, G. C., & Keech, M. K. (1960) · Biochemical Journal · doi:10.1042/bj0750588 · Cited by 443
Regulation of extracellular matrix gene expression by mechanical stress
Chiquet, M. (1999) · Matrix Biology · doi:10.1016/s0945-053x(99)00039-6 · Cited by 427
Pins, G. D., Christiansen, D. L., Patel, R., & Silver, F. H. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78247-x · Cited by 390
Research works printed but not linked: 1
- Bateman, J. F., Lamande, S. R., and Ramshaw, J. A. M., 1996, “Collagen Superfamily,” Extracellular Matrix Vol. 2., Molecular Components and Interaction, ed., W. D. Comper, Harwood Academic Publishers, The Netherlands, pp. 22–67.
Cited by
Matrix elasticity directs stem cell lineage specification
Engler, A. J., Sen, S., Sweeney, H. L., & Discher, D. E. (2006) · Cell · doi:10.1016/j.cell.2006.06.044 · Cited by 13,915
“…Sweeney,1 and Dennis E. Discher1,2,3,4,* 1Pennsylvania Muscle Institute 2School of Engineering and Applied Science 3Cell & Molecular Biology Graduate Group 4Physics Graduate Group University of Pennsylvania, Philadelphia, PA 19104, USA *Contact: discher@seas.upenn.edu DOI 10.1016/j.cell.2006.06.044”
BackgroundInfluentialRezakhaniha, R., Agianniotis, A., Schrauwen, J. T. C., Griffa, A., Sage, D., Bouten, C. V. C., van de Vosse, F. N., Unser, M., & Stergiopulos, N. (2012) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-011-0325-z · Cited by 1,096
“Techniques for 3D visualization of collagen without specific probes include auto-fluorescence , confocal reflection microscopy (Roeder et al. 2002), and second harmonic generation using femtosecond pulsed infrared excitation (Boulesteix et al. 2006).”
BackgroundScaffold Design for Bone Regeneration
Polo-Corrales, L., Latorre-Esteves, M., & Ramirez-Vick, J. E. (2014) · Journal of Nanoscience and Nanotechnology · doi:10.1166/jnn.2014.9127 · Cited by 945
Fibroblast biology in three-dimensional collagen matrices
Grinnell, F. (2003) · Trends in Cell Biology · doi:10.1016/s0962-8924(03)00057-6 · Cited by 819
Provenzano, P. P., Inman, D. R., Eliceiri, K. W., & Keely, P. J. (2009) · Oncogene · doi:10.1038/onc.2009.299 · Cited by 675
“These results suggest that increased resistance to matrix contraction regulates epithelial behavior, and further support the conclusion that the physical properties of the microenvironment are important regulators of epithelial phenotype.”
Influential
Metadata
- Authors
- Roeder, B. A., Kokini, K., Sturgis, J. E., Robinson, J. P., & Voytik-Harbin, S. L.
- Affiliations
- Purdue University West Lafayette (US)
- Department of Basic Medical Sciences/Department of Biomedical Engineering, Purdue University, West Lafayette, IN 47907-1515
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2002-03-29
- Volume
- 124
- Issue
- 2
- Pages
- 214-222
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2133809313
- Semantic Scholar
- 6d026775d9662abbe0965c21925caeb1f0a96e7c
- Cited by
- 620
- References
- 41
- Citations by year
- 2026: 13 · 2025: 21 · 2024: 16 · 2023: 23 · 2022: 24 · 2021: 29 · 2020: 34 · 2019: 40 · 2018: 24 · 2017: 32 · 2016: 33 · 2015: 42 · 2014: 37 · 2013: 40 · 2012: 33
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomechanical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- Division of Graduate Education
- Topics
- Physical Sciences › Materials Science › Biomaterials › Collagen: Extraction and Characterization
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
- Keywords
- type I collagen, extracellular matrix, collagen fibrils, tensile properties, collagen content, fibril diameter, fibril length, strain rate sensitivity, stress-strain behavior, tissue engineering scaffolds, cell-matrix interactions, mechanotransduction
- MeSH terms
- Animals, Cattle, Elasticity, Extracellular Matrix, Hydrogen-Ion Concentration, Microscopy, Interference, Models, Biological, Polymers, Sensitivity and Specificity, Stress, Mechanical, Tensile Strength, Reproducibility of Results, Microscopy, Confocal, Collagen Type I, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tensile Mechanical Properties of Three-Dimensional Type I Collagen Extracellular Matrices With Varied Microstructure. https://app.cochat.ai/papers/10.1115/1.1449904
- The paper
- Roeder, B. A., Kokini, K., Sturgis, J. E., Robinson, J. P., & Voytik-Harbin, S. L. (2002). Tensile Mechanical Properties of Three-Dimensional Type I Collagen Extracellular Matrices With Varied Microstructure. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.1449904
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.