The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Dose-dependent cytotoxicity of clinically relevant cobalt nanoparticles and ions on macrophages in vitro
Abstract
Despite the satisfactory short-term implant survivorship of metal-on-metal hip resurfacing arthroplasty, periprosthetic soft-tissue masses such as pseudotumours are being increasingly reported. Cytotoxic effects of cobalt or chromium have been suggested to play a role in its aetiology. The aim of this study was to investigate the effects of clinically relevant metal nanoparticles and ions on the viability of macrophages in vitro. A RAW 264.7 murine macrophage cell line was cultured in the presence of either: (1) cobalt, chromium and titanium nanoparticles sized 30-35 nm; or (2) cobalt sulphate and chromium chloride. Two methods were used to quantify cell viability: Alamar Blue assay and Live/Dead assay. The cytotoxicity was observed only with cobalt. Cobalt nanoparticles and ions demonstrated dose-dependent cytotoxic effects on macrophages in vitro: the cytotoxic concentrations of nanoparticles and ions were 1 x 10(12) particles ml(-1) and 1000 microM, respectively. The high concentration of cobalt nanoparticles required for cytotoxicity of macrophages in vitro suggests that increased production of cobalt nanoparticles in vivo, due to excessive MoM implant wear, may lead to local adverse biological effects. Therefore, cytotoxicity of high concentrations of metal nanoparticles phagocytosed by macrophages located in the periprosthetic tissues may be an important factor in pathogenesis of pseudotumours.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review on macrophage responses to biomaterials
Xia, Z., & Triffitt, J. T. (2006) · Biomedical Materials · doi:10.1088/1748-6041/1/1/r01 · Cited by 418
Self-citation
Cited by
Cobalt toxicity in humans—A review of the potential sources and systemic health effects
Leyssens, L., Vinck, B., Van Der Straeten, C., Wuyts, F., & Maes, L. (2017) · Toxicology · doi:10.1016/j.tox.2017.05.015 · Cited by 1,045
Abbasi, R., Shineh, G., Mobaraki, M., Doughty, S., & Tayebi, L. (2023) · Journal of Nanoparticle Research · doi:10.1007/s11051-023-05690-w · Cited by 623
Ayala-Orozco, C., Urban, C., Knight, M. W., Urban, A. S., Neumann, O., Bishnoi, S. W., Mukherjee, S., Goodman, A. M., Charron, H., Mitchell, T., et al. (2014) · ACS Nano · doi:10.1021/nn501871d · Cited by 381
Biomedical Implants with Charge‐Transfer Monitoring and Regulating Abilities
Wang, D., Tan, J., Zhu, H., Mei, Y., & Liu, X. (2021) · Advanced Science · doi:10.1002/advs.202004393 · Cited by 49
Metadata
- Authors
- Kwon, Y.-M., Xia, Z., Glyn-Jones, S., Beard, D., Gill, H. S., & Murray, D. W.
- Venue
- Biomedical Materials
- Publisher
- IOP Publishing
- Published
- 2009-04
- Volume
- 4
- Issue
- 2
- Pages
- 025018
- ISSN
- 1748-6041 (ISSN-L)
- 1748-605X
- OpenAlex
- W1965897070
- Cited by
- 167
- References
- 1
- FWCI
- 13.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dose-dependent cytotoxicity of clinically relevant cobalt nanoparticles and ions on macrophages in vitro. https://app.cochat.ai/papers/10.1088/1748-6041/4/2/025018
- The paper
- Kwon, Y.-M., Xia, Z., Glyn-Jones, S., Beard, D., Gill, H. S., & Murray, D. W. (2009). Dose-dependent cytotoxicity of clinically relevant cobalt nanoparticles and ions on macrophages in vitro. Biomedical Materials. https://doi.org/10.1088/1748-6041/4/2/025018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.