Cited by 8biodegradable polymer synthesis and propertiesTissue Engineering and Regenerative MedicineAnatomy and Medical Technology

3D printed polycaprolactone/poly (L-lactide-co-ϵ-caprolactone) composite ureteral stent with biodegradable and antibacterial properties

Teng, Yanjiao, Wang, Xinyan, Song, Lin, Yang, Jianing, Hou, Shike, Lv, Qi, Jiang, Li, Guan, Yong +1 more·2025·Biomedical Materials

Abstract

The clinical application of biodegradable ureteral stents holds significant potential. There is an urgent need to develop new materials for ureteral stents to address the limitations related to performance degradation and antibacterial properties observed in current designs. Here, we developed a Polycaprolactone (PCL)/Poly (L-lactide-co- ϵ -caprolactone) (PLCL) composite ureteral stent by three-dimensional (3D) printing, which exhibits biodegradable and antibacterial properties. Silver nanoparticles (AgNPs) were bonded to the surface of the stent through the polymerization of dopamine (PDA) and coating with type I collagen (Col I). The ureteral stent (PP-PDA-Ag-Col) had a densely spiraled structure and higher hydrophilicity. The release behavior of silver ions from the stent was found to be slow and continuous when coated with AgNPs, which can enable long-term antibacterial effects after being implanted in vivo . Additionally, in vitro degradation experiments demonstrated that the different ratios of ureteral stents degraded slowly in artificial urine over 6 weeks without compromising functionality. The stent exhibits excellent hemocompatibility and cell compatibility. The subcutaneous implantation experiment in Sprague–Dawley rats showed that the PP-PDA-Ag-Col stent degraded slowly in vivo and had good biocompatibility. The stent PCL5/PLCL5 was the most promising ureteral stent regarding antibacterial, mechanical properties, and degradation. The novel 3D-printed PP-PDA-Ag-Col stent exhibits biocompatibility for safe in vivo transplantation and antibacterial properties that reduce reliance on antibiotics. Additionally, its biodegradability eliminates the need for secondary surgical removal, making it a promising option for the clinical application of ureteral stents.

Integrity signals

Registry

Crossref · 10.1088/1748-605x/adb2ce

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • PLCL has become an important biomaterial in biomedical engineering due to its excellent biocompatibility, tunable biodegradability, and multifunctional mechanical properties.

    “Poly (L-lactide-co-ε-caprolactone) (PLCL) has become an important biomaterial in biomedical engineering due to its excellent biocompatibility, tunable biodegradability, and multifunctional mechanical properties [1–4].”
  • FDM printing temperature is typically above the melting temperature of PLCL, and the high-temperature process is not suitable for incorporating bioactive molecules that inactivate at high temperatures.

    “The printing temperature of FDM is typically above the melting temperature of PLCL. The high-temperature printing process is not suitable for incorporating bioactive molecules that inactivate at high temperatures, thus imposing certain limitations on FDM printing [1].”
  • Through various fabrication techniques and by incorporating drugs, cells, or bioactive factors, PLCL has been successfully applied across diverse fields, including skin wound healing, neural repair, osteochondral regeneration, vascular and urethral graft fabrication, biological meshes, drug delivery, and stem cell culture.

    “Furthermore, through various fabrication techniques and by incorporating drugs, cells, or bioactive factors, PLCL has been successfully applied across diverse fields, including skin wound healing, neural repair, osteochondral regeneration, vascular and urethral graft fabrication, biological meshes, drug delivery, and stem cell culture [1, 18, 196, 225, 229–231].”

The citation lists haven’t been fetched yet

References 60 · Cited by 8

Authors
Teng, Y., Wang, X., Song, L., Yang, J., Hou, S., Lv, Q., Jiang, L., Guan, Y., & Shi, J.
Affiliations
  • Tianjin University (CN)
  • State Key Laboratory of Pharmaceutical Biotechnology (CN)
  • Nankai University (CN)
Venue
Biomedical Materials
Published
2025-02-14
Volume
20
Issue
2
Pages
025026
ISSN
  • 1748-6041 (ISSN-L)
  • 1748-605X
OpenAlex
W4407186005
Cited by
8
References
60
Citations by year
2026: 5 · 2025: 3
FWCI
1.68
Type
journal article
Language
en
Open access
closed
Locations
  • Biomedical Materials (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Tianjin Science and Technology Plan (20JCYBJC01240)
  • National Natural Science Foundation of China (32101101)
Topics
  • Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Physical Sciences › Engineering › Biomedical Engineering › Anatomy and Medical Technology
Keywords
ureteral stent, polycaprolactone, poly(L-lactide-co-ε-caprolactone), 3D-printed stents, silver nanoparticles, antibacterial coatings, type I collagen coating, biodegradable polymer composites, hemocompatibility, biocompatibility, in vivo degradation
MeSH terms
Animals, Anti-Bacterial Agents, Biocompatible Materials, Escherichia coli, Humans, Male, Materials Testing, Polyesters, Silver, Staphylococcus aureus, Ureter, Stents, Rats, Sprague-Dawley, Absorbable Implants, Collagen Type I, Rats, Metal Nanoparticles, Printing, Three-Dimensional

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review