Volatile signature for the early diagnosis of lung cancer

Open access
Gasparri, Roberto, Santonico, Marco, Valentini, Claudia, Sedda, Giulia, Borri, Alessandro, Petrella, Francesco, Maisonneuve, Patrick, Pennazza, Giorgio, D’Amico, Arnaldo, Di Natale, Corrado, Paolesse, Roberto, Spaggiari, Lorenzo · 2016 · Journal of Breath Research
Cited by 156

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Exhaled breath contains hundreds of volatile organic compounds (VOCs). Several independent researchers point out that the breath of lung cancer patients shows a characteristic VOC-profile which can be considered as lung cancer signature and, thus, used for diagnosis. In this regard, the analysis of exhaled breath with gas sensor arrays is a potential non-invasive, relatively low-cost and easy technique for the early detection of lung cancer. This clinical study evaluated the gas sensor array response for the identification of the exhaled breath of lung cancer patients. This study involved 146 individuals: 70 with lung cancer confirmed by computerized tomography (CT) or positron emission tomography-(PET) imaging techniques and histology (biopsy) or with clinical suspect of lung cancer and 76 healthy controls. Their exhaled breath was measured with a gas sensor array composed of a matrix of eight quartz microbalances (QMBs), each functionalized with a different metalloporphyrin. The instrument produces, for each analyzed sample, a vector of signals encoding the breath (breathprint). Breathprints were analyzed with multivariate analysis in order to correlate the sensor signals to the disease. Breathprints of the lung cancer patients were differentiated from those of the healthy controls with a sensitivity of 81% and specificity of 91%. Similar values were obtained in patients with and without metabolic comorbidities, such as diabetes, obesity and dyslipidemia (sensitivity 85%, specificity 88% and sensitivity 76%, specificity 94%, respectively). The device showed a large sensitivity to lung cancer at stage I with respect to stage II/III/IV (92% and 58% respectively). The sensitivity for stage I did not change for patients with or without metabolic comorbidities (90%, 94%, respectively). Results show that this electronic nose can discriminate the exhaled breath of the lung cancer patients from those of the healthy controls. Moreover, the largest sensitivity is observed for the subgroup of patients with a lung cancer at stage I.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1752-7155/10/1/016007

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 156

Metadata

Authors
Gasparri, R., Santonico, M., Valentini, C., Sedda, G., Borri, A., Petrella, F., Maisonneuve, P., Pennazza, G., D’Amico, A., Di Natale, C., Paolesse, R., & Spaggiari, L.
Venue
Journal of Breath Research
Published
2016-02-09
Volume
10
Issue
1
Pages
016007
ISSN
  • 1752-7155 (ISSN-L)
  • 1752-7163
OpenAlex
W2267245086
Cited by
156
References
3
FWCI
8.66
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Volatile signature for the early diagnosis of lung cancer. https://app.cochat.ai/papers/10.1088/1752-7155/10/1/016007
The paper
Gasparri, R., Santonico, M., Valentini, C., Sedda, G., Borri, A., Petrella, F., Maisonneuve, P., Pennazza, G., D’Amico, A., Di Natale, C., Paolesse, R., & Spaggiari, L. (2016). Volatile signature for the early diagnosis of lung cancer. Journal of Breath Research. https://doi.org/10.1088/1752-7155/10/1/016007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.