Cited by 96Lower Extremity Biomechanics and PathologiesSports Dynamics and BiomechanicsKnee injuries and reconstruction techniques

Biomechanical analysis using Kinovea for sports application

Open access
Nor Adnan, Nor Muaza, Ab Patar, Mohd Nor Azmi, Lee, Hokyoo, Yamamoto, Shin-Ichiroh, Jong-Young, Lee, Mahmud, Jamaluddin·2018·IOP Conference Series: Materials Science and Engineering

Abstract

This paper assesses the reliability of HD VideoCam–Kinovea as an alternative tool in conducting motion analysis and measuring knee relative angle of drop jump movement. The motion capture and analysis procedure were conducted in the Biomechanics Lab, Shibaura Institute of Technology, Omiya Campus, Japan. A healthy subject without any gait disorder (BMI of 28.60 ± 1.40) was recruited. The volunteered subject was asked to per the drop jump movement on preset platform and the motion was simultaneously recorded using an established infrared motion capture system (Hawk–Cortex) and a HD VideoCam in the sagittal plane only. The capture was repeated for 5 times. The outputs (video recordings) from the HD VideoCam were input into Kinovea (an open-source software) and the drop jump pattern was tracked and analysed. These data are compared with the drop jump pattern tracked and analysed earlier using the Hawk–Cortex system. In general, the results obtained (drop jump pattern) using the HD VideoCam–Kinovea are close to the results obtained using the established motion capture system. Basic statistical analyses show that most average variances are less than 10%, thus proving the repeatability of the protocol and the reliability of the results. It can be concluded that the integration of HD VideoCam–Kinovea has the potential to become a reliable motion capture–analysis system. Moreover, it is low cost, portable and easy to use. As a conclusion, the current study and its findings are found useful and has contributed to enhance significant knowledge pertaining to motion capture-analysis, drop jump movement and HD VideoCam–Kinovea integration.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1757-899x/342/1/012097

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Kinovea relies on manual and semi-automated tracking, without deep learning-based pose estimation, which limits its capacity for fully automated and real-time movement quantification.

    “However, its reliance on manual and semi-automated tracking, without deep learning-based pose estimation, limits its capacity for fully automated and real-time movement quantification [6].”

    From PyBodyTrack: A python library for multi-algorithm motion quantification and tracking in videos (2025) · cites this paper as [6]

    Section 2.4 (page not provided) describes selecting recorded videos and locating five markers in Kinovea, after which Kinovea tracks their movement through the capture. This supports a manually initialized tracking workflow, but the paper does not address deep learning-based pose estimation or establish that this workflow limits fully automated or real-time quantification. (LLM, conf=0.86)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 13

  1. J. Schiffer, "Plyometric Training and the High Jump," New Stud. Athl., no. 3, pp. 9-21, 2012.
  2. S. Ramachandran and B. Pradhan, "Effects of short-term two weeks low intensity plyometrics combined with dynamic stretching training in improving vertical jump height and agility on trained basketball players," Indian J. Physiol. Pharmacol., vol. 58, no. 2, 2014.
  3. K. Bujang, A. F. A. Nazri, A. F. Ahmad Azam, and J. Mahmud, "Development of a motion capture system using kinect," J. Teknol., vol. 76, no. 11, pp. 75-86, 2015.
  4. D. Winter, The Biomechanics and Motor Control of Human Gait: Normal, Elderly and Pathological, vol. 2nd. 1991.
  5. B. Requena, F. Requena, I. García, E. S. S. de Villarreal, and M. Pääsuke, "Reliability and validity of a wireless microelectromechanicals based system for measuring vertical jumping performance," J. Sport. Sci. Med., vol. 11, no. 1, pp. 115-122, 2012.
  6. Mohd Nor Azmi Ab Patar, T. Komeda, C. Y. Low, and J. Mahmud, "System Integration and Control of Finger Orthosis for Post Stroke Rehabilitation," Procedia Technol., vol. 15, pp. 756-765, 2014.
  7. J. Mahmud, C. A. Holt, and S. L. Evans, "An innovative application of a small-scale motion analysis technique to quantify human skin deformation in vivo," J. Biomech., vol. 43, no. 5, pp. 1002-1006, 2010.
  8. G. Mustapha, M. F. Abd Razak, M. S. Mohd Hamzah, N. H. Mohd Yahya, and J. Mahmud, "The Development Of A Low Cost Motion Analysis System: Cekak Visual 3D v1.0," Int. J. GEOMATE, vol. 11, no. 24, pp. 2248-2252, 2016.
  9. K. M. S. T. Yusuf, A. F. Ahmad Nazri, G. Mustapha, and J. Mahmud, "Analysis of static and dynamic motion accuracy for kinect-virtual Sensei system," ARPN J. Eng. Appl. Sci., vol. 10, no. 17, pp. 7328-7335, 2015.
  10. M. N. A. A. Patar, T. Komeda, L. C. Yee, and J. Mahmud, "Model-based systems engineering of a hand rehabilitation device," J. Teknol., vol. 76, no. 4, pp. 101-106, 2015.
  11. M. N. A. Ab Patar, A. F. Said, J. Mahmud, A. Majeed, and M. A. Razman, "System Integration and Control of Dynamic Ankle Foot Orthosis for Lower Limb Rehabilitation," 2014 1st Int. Symp. Technol. Manag. Emerg. Technol. (Istmet 2014), pp. 82-85, 2014.
  12. C. Damsted, R. O. Nielsen, and L. H. Larsen, "Reliability of video-based quantification of the knee-and hip angle at foot strike during running.," Int. J. Sports Phys. Ther., vol. 10, no. 2, pp. 147-54, 2015.
  13. N. Amirah, H. Hisham, A. Faiz, A. Nazri, J. Madete, L. Herawati, and J. Mahmud, "Measuring Ankle Angle and Analysis of Walking Gait using Kinovea," Int. Med. Device Technol. Conf., pp. 247-250, 2017.

Cited by

Sorted by citations

Authors
Nor Adnan, N. M., Ab Patar, M. N. A., Lee, H., Yamamoto, S.-I., Jong-Young, L., & Mahmud, J.
Affiliations
  • Shibaura Institute of Technology (JP)
  • Universiti Teknologi MARA System (MY)
Venue
IOP Conference Series: Materials Science and Engineering
Published
2018-04
Volume
342
Pages
012097
ISSN
  • 1757-8981 (ISSN-L)
  • 1757-899X
OpenAlex
W2795951527
Cited by
96
References
0
Citations by year
2026: 6 · 2025: 16 · 2024: 16 · 2023: 17 · 2022: 14 · 2021: 13 · 2020: 10 · 2019: 2 · 2018: 2
FWCI
14.80
Type
conference paper
Language
en
Open access
Locations
IOP Conference Series Materials Science and Engineering (publishedVersion, cc-by)
Funders
Universiti Teknologi MARA
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
  • Physical Sciences › Engineering › Biomedical Engineering › Sports Dynamics and Biomechanics
  • Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
Keywords
video-based motion capture, Kinovea, drop jump, knee joint angle, reliability statistics, low-cost motion analysis, sports biomechanics, sagittal plane kinematics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review