Cited by 4Building Energy and Comfort OptimizationBuilding energy efficiency and sustainabilityBIM and Construction Integration

Simulation on Lighting Energy Consumption based on Building Information Modelling for Energy Efficiency at Highway Rest and Service Areas Malaysia

Open access
Neardey, M, Aminudin, E, Chung, L P, Zin, R M, Zakaria, R, Che Wahid, C M F H, Hamid, A R A, Noor, Z Z N·2020·IOP Conference Series: Materials Science and Engineering

Abstract

Abstract Building consumes 40% of global energy consumption which contributes for such a majority amount of carbon dioxide emission. Enhancing the energy efficiency strategies in buildings by retrofitting through different approaches is essential for reducing end user on the amount of energy consumption and carbon footprint emission. Previous research shows that only a few studies have been conducted on retrofitting the energy performance on Rest and Service Area yet the result shows that lack of technical feasibility practice was reviewed. Hence, this paper explores the energy efficiency strategy by improving the lighting performance based on 24 hours service building at Rest and Service Area Ayer Keroh Northbound Malaysia. The simulation that was performed in lighting energy consumption was EnergyPLUS software, Autodesk Revit and RELUX Plug in tool in Revit. Preliminary study was conducted to identity the problem on energy performance at Rest and Service Area Ayer Keroh by determine the total energy consumption by sources and Building Energy Intensity [BEI]. The result shows lighting contributes to the most total load consumption due to lack of energy conservation management and energy efficiency strategy practices. The lighting simulation scenarios was created to enhance the energy consumption performance and reduced the irrelevant carbon footprint emission. The simulation in Revit and EnergyPLUS showed 17% and 49% reduction respectively on the end load of lighting energy consumption by reducing the overall time operation and daylight control dimming system.

Integrity signals

Registry

Crossref · 10.1088/1757-899x/943/1/012062

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Neardey, M., Aminudin, E., Chung, L. P., Zin, R. M., Zakaria, R., Che Wahid, C. M. F. H., Hamid, A. R. A., & Noor, Z. Z. N.
Affiliations
  • University of Technology Malaysia (MY)
  • UTM Construction Research Centre (MY)
Venue
IOP Conference Series: Materials Science and Engineering
Published
2020-10-01
Volume
943
Issue
1
Pages
012062
ISSN
  • 1757-8981 (ISSN-L)
  • 1757-899X
OpenAlex
W3097966024
Cited by
4
References
0
Citations by year
2025: 2 · 2023: 1 · 2022: 1
FWCI
0.83
Type
conference paper
Language
en
Open access
Locations
IOP Conference Series Materials Science and Engineering (publishedVersion, cc-by)
Topics
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Physical Sciences › Engineering › Building and Construction › Building energy efficiency and sustainability
  • Physical Sciences › Engineering › Building and Construction › BIM and Construction Integration
Keywords
lighting energy consumption, building energy efficiency, building retrofit, carbon footprint reduction, EnergyPlus simulation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review