Combining electrospinning and fused deposition modeling for the fabrication of a hybrid vascular graft
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Tissue engineering of blood vessels is a promising strategy in regenerative medicine with a broad spectrum of potential applications. However, many hurdles for tissue-engineered vascular grafts, such as poor mechanical properties, thrombogenicity and cell over-growth inside the construct, need to be overcome prior to the clinical application. To surmount these shortcomings, we developed a poly-L-lactide (PLLA)/poly-epsilon-caprolactone (PCL) scaffold releasing heparin by a combination of electrospinning and fused deposition modeling technique. PLLA/heparin scaffolds were produced by electrospinning in tubular shape and then fused deposition modeling was used to armor the tube with a single coil of PCL on the outer layer to improve mechanical properties. Scaffolds were then seeded with human mesenchymal stem cells (hMSCs) and assayed in terms of morphology, mechanical tensile strength, cell viability and differentiation. This particular scaffold design allowed the generation of both a drug delivery system amenable to surmount thrombogenic issues and a microenvironment able to induce endothelial differentiation. At the same time, the PCL external coiling improved mechanical resistance of the microfibrous scaffold. By the combination of two notable techniques in biofabrication--electrospinning and FDM--and exploiting the biological effects of heparin, we developed an ad hoc differentiating device for hMSCs seeding, able to induce differentiation into vascular endothelium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review on polymer nanofibers by electrospinning and their applications in nanocomposites
Huang, Z.-M., Zhang, Y.-Z., Kotaki, M., & Ramakrishna, S. (2003) · Composites Science and Technology · doi:10.1016/s0266-3538(03)00178-7 · Cited by 7,556 · cited 1×
“Polymers loaded with growth factors, cytokines, and drugs have also been developed, generating drug-releasing systems capable of localized delivery of biomolecules [14, 15].”
BackgroundElectrospinning of Polymeric Nanofibers for Tissue Engineering Applications: A Review
Pham, Q. P., Sharma, U., & Mikos, A. G. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.1197 · Cited by 2,256 · cited 2×
“Several types of polymers have been proposed to obtain scaffolds for TEVG, such as collagen, poly-ε-caprolactone (PCL), poly-lactide (PLA), poly-glycolide (PGA) and block copolymers thereof [13].”
BackgroundYang, F., Murugan, R., Wang, S., & Ramakrishna, S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.051 · Cited by 1,804
Nanofiber technology: Designing the next generation of tissue engineering scaffolds
Barnes, C. P., Sell, S. A., Boland, E. D., Simpson, D. G., & Bowlin, G. L. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.04.022 · Cited by 1,141
Mo, X. M., Xu, C. Y., Kotaki, M., & Ramakrishna, S. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.042 · Cited by 803 · cited 2×
“The attractive features of electrospinning are the simple and inexpensive nature of the setup that can easily be adapted to the manufacturing of tubular shapes [6], and the possibility of being combined to the newest methodologies of cell seeding [8].”
BackgroundBadami, A. S., Kreke, M. R., Thompson, M. S., Riffle, J. S., & Goldstein, A. S. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.084 · Cited by 613
Shin’oka, T., Matsumura, G., Hibino, N., Naito, Y., Watanabe, M., Konuma, T., Sakamoto, T., Nagatsu, M., & Kurosawa, H. (2005) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2004.12.047 · Cited by 585 · cited 1×
“biodegradable tubular matrix with large diameter (∅ > 6 mm) [4].”
BackgroundKonig, G., McAllister, T. N., Dusserre, N., Garrido, S. A., Iyican, C., Marini, A., Fiorillo, A., Avila, H., Wystrychowski, W., Zagalski, K., et al. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.11.011 · Cited by 582
Small-Diameter Artificial Arteries Engineered In Vitro
Isenberg, B. C., Williams, C., & Tranquillo, R. T. (2006) · Circulation Research · doi:10.1161/01.res.0000196867.12470.84 · Cited by 469
Controlled release of heparin from poly(ε-caprolactone) electrospun fibers
Luong-Van, E., Grøndahl, L., Chua, K. N., Leong, K. W., Nurcombe, V., & Cool, S. M. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.028 · Cited by 445
Creation Of Viable Pulmonary Artery Autografts Through Tissue Engineering
Shinoka, T., Shum-Tim, D., Ma, P. X., Tanel, R. E., Isogai, N., Langer, R., Vacanti, J. P., & Mayer, J. E. (1998) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(98)70315-0 · Cited by 444
Cell biology of arterial proteoglycans.
Wight, T. N. (1989) · Arteriosclerosis: An Official Journal of the American Heart Association, Inc. · doi:10.1161/01.atv.9.1.1 · Cited by 410
Xu, C., Inai, R., Kotaki, M., & Ramakrishna, S. (2004) · Tissue Engineering · doi:10.1089/1076327041887736 · Cited by 399
Antithrombogenic property of bone marrow mesenchymal stem cells in nanofibrous vascular grafts
Hashi, C. K., Zhu, Y., Yang, G.-Y., Young, W. L., Hsiao, B. S., Wang, K., Chu, B., & Li, S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704581104 · Cited by 387
Nano-Featured Scaffolds for Tissue Engineering: A Review of Spinning Methodologies
Murugan, R., & Ramakrishna, S. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.435 · Cited by 387
Recent development on computer aided tissue engineering — a review
Sun, W., & Lal, P. (2002) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(01)00116-x · Cited by 360 · cited 1×
“In the emerging field of so-called computer aided tissue engineering (CATE) several groups are reporting the use of FDM for the fabrication of 3D constructs [11, 12].”
BackgroundComputer‐aided tissue engineering: overview, scope and challenges
Sun, W., Darling, A., Starly, B., & Nam, J. (2004) · Biotechnology and Applied Biochemistry · doi:10.1042/ba20030108 · Cited by 341
L'Heureux, N., Dusserre, N., Marini, A., Garrido, S., de la Fuente, L., & McAllister, T. (2007) · Nature Clinical Practice Cardiovascular Medicine · doi:10.1038/ncpcardio0930 · Cited by 292
Kim, B.-S., Putnam, A. J., Kulik, T. J., & Mooney, D. J. (1998) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19980105)57:1<46::aid-bit6>3.0.co;2-v · Cited by 272
In vitro evaluation of electrospun nanofiber scaffolds for vascular graft application
Lee, S. J., Yoo, J. J., Lim, G. J., Atala, A., & Stitzel, J. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31287 · Cited by 268 · cited 1×
“actually open challenges [38–41].”
Moroni, L., Licht, R., de Boer, J., de Wijn, J. R., & van Blitterswijk, C. A. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.05.027 · Cited by 254
Electrospun polydioxanone–elastin blends: potential for bioresorbable vascular grafts
Sell, S. A., McClure, M. J., Barnes, C. P., Knapp, D. C., Walpoth, B. H., Simpson, D. G., & Bowlin, G. L. (2006) · Biomedical Materials · doi:10.1088/1748-6041/1/2/004 · Cited by 216
Review: Advances in Vascular Tissue Engineering Using Protein-Based Biomaterials
Stegemann, J. P., Kaszuba, S. N., & Rowe, S. L. (2007) · Tissue Engineering · doi:10.1089/ten.2007.0196 · Cited by 205
Fabrication of cell microintegrated blood vessel constructs through electrohydrodynamic atomization
Stankus, J. J., Soletti, L., Fujimoto, K., Hong, Y., Vorp, D. A., & Wagner, W. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.02.012 · Cited by 198
Nieponice, A., Soletti, L., Guan, J., Deasy, B. M., Huard, J., Wagner, W. R., & Vorp, D. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.10.044 · Cited by 191
Kim, G., Son, J., Park, S., & Kim, W. (2008) · Macromolecular Rapid Communications · doi:10.1002/marc.200800277 · Cited by 172
Zero-order release of lysozyme from poly(ethylene glycol)/poly(butylene terephthalate) matrices
Bezemer, J. M., Radersma, R., Grijpma, D. W., Dijkstra, P. J., Feijen, J., & van Blitterswijk, C. A. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00127-3 · Cited by 170 · cited 1×
“Regarding the reported two-phase release profile, consisting of an initial burst followed by sustained release, similar behavior is reported in the literature [33, 34, 42].”
ResultMironov, V., Kasyanov, V. A., & Markwald, R. R. (2008) · Trends in biotechnology · doi:10.1016/j.tibtech.2008.03.001 · Cited by 151
Controlled release of dual drugs from emulsion electrospun nanofibrous mats
Su, Y., Li, X., Shuiping, L., Mo, X., & Ramakrishna, S. (2009) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2009.06.009 · Cited by 141
Smith, M. J., McClure, M. J., Sell, S. A., Barnes, C. P., Walpoth, B. H., Simpson, D. G., & Bowlin, G. L. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.08.001 · Cited by 132
Spadaccio, C., Rainer, A., Trombetta, M., Vadalà, G., Chello, M., Covino, E., Denaro, V., Toyoda, Y., & Genovese, J. A. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9704-3 · Cited by 127
Self-citationChabut, D., Fischer, A., Colliec‐Jouault, S., Laurendeau, I., Matou, S., Bonniec, B. L., & Helley, D. (2003) · Molecular Pharmacology · doi:10.1124/mol.64.3.696 · Cited by 89 · cited 1×
“It is noteworthy that this concentration has been used in previous studies that showed endothelial differentiation induced by addition of heparin to culture media [17].”
MethodBiodegradable honeycomb collagen scaffold for dermal tissue engineering
George, J., Onodera, J., & Miyata, T. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32277 · Cited by 85
Engineering of an elastic large muscular vessel wall with pulsatile stimulation in bioreactor
Xu, Z. C., Zhang, W. J., Li, H., Cui, L., Cen, L., Zhou, G. D., Liu, W. X., & Cao, Y. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.037 · Cited by 72
Drug releasing systems in cardiovascular tissue engineering
Spadaccio, C., Chello, M., Trombetta, M., Rainer, A., Toyoda, Y., & Genovese, J. A. (2008) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2008.00532.x · Cited by 65
Self-citationElectrostimulation induces cardiomyocyte predifferentiation of fibroblasts
Genovese, J. A., Spadaccio, C., Langer, J., Habe, J., Jackson, J., & Patel, A. N. (2008) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2008.03.115 · Cited by 57
Self-citationYang, Z., Birkenhauer, P., Julmy, F., Chickering, D. E., Ranieri, J. P., Merkle, H. P., Lüscher, T. F., & Gander, B. A. (1999) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00078-4 · Cited by 55 · cited 1×
“[32].”
Covalent Surface Heparinization Potentiates Porous Polyurethane Scaffold Vascularization
Bezuidenhout, D., Davies, N. H., Black, M., Schmidt, C. A., Oosthuysen, A., & Zilla, P. (2008) · Journal of Biomaterials Applications · doi:10.1177/0885328208097565 · Cited by 43 · cited 1×
“This finding was confirmed by CD31 expression, flow cytometry, and is consistent with the previous reports describing increased presence of CD31 positive microvessels following subcutaneous application of a covalently-bound heparin-modified porous polyurethane scaffold [46].”
ResultRawat, A., Yang, T., Hussain, A., & Ahsan, F. (2007) · Pharmaceutical Research · doi:10.1007/s11095-007-9442-x · Cited by 21 · cited 1×
“Heparin release rate was assayed using the Azure A spectrofluorimetric method developed by Jacques et al [21].”
MethodSerizawa, N., Takei, Y., Okubo, H., YAMASINA, S., ENOMOTO, N., & Sato, N. (2006) · Hepatology Research · doi:10.1016/j.hepres.2006.01.005 · Cited by 3 · cited 1×
“Moreover, heparin plays a crucial role in endothelial cell adhesion and homeostasis, improves cell attachment to the scaffold, providing trophic and differentiating signaling [44], and prevents early thrombosis [45].”
Background
Cited by
The future of dental devices is digital
van Noort, R. (2012) · Dental Materials · doi:10.1016/j.dental.2011.10.014 · Cited by 1,408
The Tissue-Engineered Vascular Graft—Past, Present, and Future
Pashneh-Tala, S., MacNeil, S., & Claeyssens, F. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0100 · Cited by 798
Electrospun scaffolds for tissue engineering of vascular grafts
Hasan, A., Memic, A., Annabi, N., Hossain, M., Paul, A., Dokmeci, M. R., Dehghani, F., & Khademhosseini, A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.08.022 · Cited by 742
Current trends in the design of scaffolds for computer-aided tissue engineering
Giannitelli, S. M., Accoto, D., Trombetta, M., & Rainer, A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.10.024 · Cited by 451
Self-citationBioprinting for vascular and vascularized tissue biofabrication
Datta, P., Ayan, B., & Ozbolat, I. T. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.01.035 · Cited by 431
Metadata
- Authors
- Centola, M., Rainer, A., Spadaccio, C., De Porcellinis, S., Genovese, J. A., & Trombetta, M.
- Venue
- Biofabrication
- Publisher
- IOP Publishing
- Published
- 2010-03-01
- Volume
- 2
- Issue
- 1
- Pages
- 014102
- ISSN
- 1758-5082 (ISSN-L)
- 1758-5090
- OpenAlex
- W2163976095
- Cited by
- 177
- References
- 40
- FWCI
- 2.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.