Bio rapid prototyping by extruding/aspirating/refilling thermoreversible hydrogel
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper reports a method for rapid prototyping of cell tissues, which is based on a system that extrudes, aspirates and refills a mixture of cells and thermoreversible hydrogel as a scaffold. In the extruding mode, a cell-mixed scaffold solution in the sol state is extruded from a cooled micronozzle into a temperature-controlled substrate, which keeps the scaffold in the gel state. In the aspiration mode, the opposite process is performed by Bernoulli suction. In the refilling mode, the solution is extruded into a groove created in the aspiration mode. The minimum width of extruded hydrogel pattern is 114 +/- 15 microm by employing a nozzle of diameter 100 microm, and that of aspirated groove was 355 +/- 10 microm using a 500 microm-diameter nozzle. Gum arabic is mixed with the scaffold solution to avoid peeling-off of the gel pattern from the substrate. Patterning of Sf-9 cell tissue is demonstrated, and the stability of the patterned cell is investigated. This system offers a procedure for rapid prototyping and local modification of cell scaffolds for tissue engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Taking Cell-Matrix Adhesions to the Third Dimension
Cukierman, E., Pankov, R., Stevens, D. R., & Yamada, K. M. (2001) · Science · doi:10.1126/science.1064829 · Cited by 3,027
Exploring and Engineering the Cell Surface Interface
Stevens, M. M., & George, J. H. (2005) · Science · doi:10.1126/science.1106587 · Cited by 2,607
Cited by
3D bioprinting of tissues and organs
Murphy, S. V., & Atala, A. (2014) · Nature Biotechnology · doi:10.1038/nbt.2958 · Cited by 7,034
25th Anniversary Article: Engineering Hydrogels for Biofabrication
Malda, J., Visser, J., Melchels, F. P., Jüngst, T., Hennink, W. E., Dhert, W. J. A., Groll, J., & Hutmacher, D. W. (2013) · Advanced Materials · doi:10.1002/adma.201302042 · Cited by 1,901
A review of trends and limitations in hydrogel-rapid prototyping for tissue engineering
Billiet, T., Vandenhaute, M., Schelfhout, J., Van Vlierberghe, S., & Dubruel, P. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.04.050 · Cited by 1,284
Strategies and Molecular Design Criteria for 3D Printable Hydrogels
Jungst, T., Smolan, W., Schacht, K., Scheibel, T., & Groll, J. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00303 · Cited by 712
Biomaterials for Integration with 3-D Bioprinting
Skardal, A., & Atala, A. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1207-1 · Cited by 474
Metadata
- Authors
- Iwami, K., Noda, T., Ishida, K., Morishima, K., Nakamura, M., & Umeda, N.
- Venue
- Biofabrication
- Publisher
- IOP Publishing
- Published
- 2010-03-01
- Volume
- 2
- Issue
- 1
- Pages
- 014108
- ISSN
- 1758-5082 (ISSN-L)
- 1758-5090
- OpenAlex
- W2007252347
- Cited by
- 76
- References
- 2
- FWCI
- 2.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bio rapid prototyping by extruding/aspirating/refilling thermoreversible hydrogel. https://app.cochat.ai/papers/10.1088/1758-5082/2/1/014108
- The paper
- Iwami, K., Noda, T., Ishida, K., Morishima, K., Nakamura, M., & Umeda, N. (2010). Bio rapid prototyping by extruding/aspirating/refilling thermoreversible hydrogel. Biofabrication. https://doi.org/10.1088/1758-5082/2/1/014108
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.